Home › HYBRID SYSTEM · P310 › HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A94-554    DC / DC Converter Performance

DTC    P0A94-555    DC / DC Converter Performance

for Preparation Click here


DESCRIPTION

Refer to the description of the boost converter .

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A94
554
Boost converter inverter fail signal detection (overcurrent by MG ECU malfunction)
  1. Wire harness or connector
  2. Hybrid vehicle transaxle assembly
  3. Rear traction motor with transaxle assembly
  4. Inverter with converter assembly (MG ECU)
  5. No. 3 frame wire
  6. Extension wire assembly
555
Boost converter inverter fail signal detection (overcurrent by inverter assembly malfunction)

MONITOR DESCRIPTION

If excessive amperage flows through the boost converter due to an internal short, the boost converter will transmit a boost converter fail signal to the MG ECU. The MG ECU will send information about the malfunction to the hybrid vehicle control ECU. Upon receiving this information, the hybrid vehicle control ECU will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A94 (INF 554/555): FCV detection load short circuit
Required sensors / components
Boost converter
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the DTCs listed are not present
TMC's intellectual property

TYPICAL MALFUNCTION THRESHOLDS


Boost converter
Overcurrent (internal short)

COMPONENT OPERATING RANGE


Boost converter
DTC P0A94 (INF 554/555) is not detected

WIRING DIAGRAM

Refer to the wiring diagrams for DTC P0A1A-200 , P0A1B-168 and P0A1C-715 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals. After waiting for 5 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

HINT:
Waiting for at least 5 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

1.CHECK DTC OUTPUT (HV)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Select the following menu items: DIAGNOSIS / Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A94-554 or 555 only is output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A1D (all INF codes) *1
    Hybrid Powertrain Control Module
    P0A2B-248, 250
    Drive Motor "A" Temperature Sensor Circuit Range / Performance
    P0A2C-247
    Drive Motor "A" Temperature Sensor Circuit Low
    P0A2D-249
    Drive Motor "A" Temperature Sensor Circuit High
    P0A37-258, 260
    Generator Temperature Sensor Circuit Range / Performance
    P0A38-257
    Generator Temperature Sensor Circuit Low
    P0A39-259
    Generator Temperature Sensor Circuit High
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range / Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A45-669
    Drive Motor "B" Position Sensor Circuit
    P0A46-671
    Drive Motor "B" Position Sensor Circuit Range / Performance
    P0A47-670
    Drive Motor "B" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range / Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A55-687
    Drive Motor "B" Current Sensor Circuit
    P0A60 (all INF codes) *1
    Drive Motor "A" Phase V Current
    P0A63 (all INF codes) *1
    Drive Motor "A" Phase W Current
    P0A69 (all INF codes) *1
    Drive Motor "B" Phase V Current
    P0A6C (all INF codes) *1
    Drive Motor "B" Phase W Current
    P0A72 (all INF codes) *1
    Generator Phase V Current
    P0A75 (all INF codes) *1
    Generator Phase W Current
    P0A78 (all INF codes) *1
    Drive Motor "A" Inverter Performance
    P0A79 (all INF codes) *1
    Drive Motor "B" Inverter Performance
    P0A7A (all INF codes) *1
    Generator Inverter Performance
    P0A90-251, 509
    Drive Motor "A" Performance
    P0A92-261, 521
    Hybrid Generator Performance
    P0A94-442, 545, 546, 547, 548, 549, 550, 551, 552, 553, 556, 557, 558, 559, 561, 585, 587, 588, 589, 590
    DC / DC Converter Performance
    P0AA6 (all INF codes) *1
    Hybrid Battery Voltage System Isolation Fault
    P0ADB-227
    Hybrid Battery Positive Contactor Control Circuit Low
    P0ADC-226
    Hybrid Battery Positive Contactor Control Circuit High
    P0ADF-229
    Hybrid Battery Negative Contactor Control Circuit Low
    P0AE0-228
    Hybrid Battery Negative Contactor Control Circuit High
    P0AE6-225
    Hybrid Battery Positive Contactor Circuit Stuck Open
    P0AE7-224
    Hybrid Battery Precharge Contactor Control Circuit High
    P0AF8-816
    Hybrid Battery System Voltage
    P3004 (all INF codes) *1
    Power Cable Malfunction
    P3227-583
    Converter Temperature Sensor Circuit Low
    P3228-584
    Converter Temperature Sensor Circuit High

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic flowchart.
    2. Turning the power switch on (IG) with the service plug grip and inverter cover removed causes interlock switch system DTC P0A0D-350 to be output.
    3. P0A94-554 and P0A94-555 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.



B
GO TO DTC CHART (Click here)
A


2.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the power switch off.

  1. Remove the service plug grip (Click here).

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the inverter cover (Click here).

    NOTICE:
    1. Wrap the round interlock terminal for the inverter cover with insulating tape to prevent it from shorting to ground.
    2. Be sure to prevent coolant in the inverter reserve tank from entering the inverter.
    3. Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.



    A170989E01
  1. Check the connections of the MG ECU connectors.

    OK:
    The connectors are connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


3.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.



    A174452E02
  1. Disconnect the three-phase AC cable for MG2 from the inverter with converter assembly.



    A111755E04
  1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    U - V
    Power switch off
    (68°F (20°C))
    52.4 to 58.4 mΩ
    V - W
    Power switch off
    (68°F (20°C))
    50.5 to 56.5 mΩ
    W - U
    Power switch off
    (68°F (20°C))
    50.5 to 56.5 mΩ

    NOTICE:
    If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

  1. To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 68°F (20°C).

    HINT:
    1. R20 = Rt / {1 + 0.00393 X (T - 20)}
    2. R20: Resistance at 68°F (20°C) (mΩ)
    3. Rt: Measured resistance (mΩ)
    4. T: Temperature when the resistance is measured (°C)

  1. Calculate the difference between the maximum and minimum resistance.

    Standard resistance:
    Difference is 5 mΩ or less

  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    U - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    V - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    W - Body ground and shield ground
    Power switch off
    100 MΩ or higher



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK


4.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.



    A175186E03
  1. Disconnect the three-phase AC cable for MG1 from the inverter with converter assembly.



    A111753E04
  1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    U - V
    Power switch off
    (68°F (20°C))
    37 to 41 mΩ
    V - W
    Power switch off
    (68°F (20°C))
    36 to 40 mΩ
    W - U
    Power switch off
    (68°F (20°C))
    36 to 40 mΩ

    NOTICE:
    If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

  1. To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 68°F (20°C).

    HINT:
    1. R20 = Rt / {1 + 0.00393 X (T - 20)}
    2. R20: Resistance at 68°F (20°C) (mΩ)
    3. Rt: Measured resistance (mΩ)
    4. T: Temperature when the resistance is measured (°C)

  1. Calculate the difference between the maximum and minimum resistance.

    Standard resistance:
    Difference is 3 mΩ or less

  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    U - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    V - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    W - Body ground and shield ground
    Power switch off
    100 MΩ or higher



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK


5.CHECK REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.



    A174239E06
  1. Disconnect the three-phase AC cable for MGR from the inverter with converter assembly.



    A174892E03
  1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    U - V
    Power switch off
    (68°F (20°C))
    147 to 157 mΩ
    V - W
    Power switch off
    (68°F (20°C))
    147 to 157 mΩ
    W - U
    Power switch off
    (68°F (20°C))
    147 to 157 mΩ

    NOTICE:
    If the MGR temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

  1. To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 68°F (20°C).

    HINT:
    1. R20 = Rt / {1 + 0.00393 X (T - 20)}
    2. R20: Resistance at 20°C (mΩ)
    3. Rt: Measured resistance (mΩ)
    4. T: Temperature when the resistance is measured (°C)

  1. Calculate the difference between the maximum and minimum resistance.

    Standard resistance:
    Difference is 5 mΩ or less

  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    U - Body ground and shield ground
    Power switch off
    10 MΩ or higher
    V - Body ground and shield ground
    Power switch off
    10 MΩ or higher
    W - Body ground and shield ground
    Power switch off
    10 MΩ or higher



NG
Go to step 23
OK


6.CHECK HARNESS AND CONNECTOR (MG ECU - MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

  1. Disconnect connector B49 from the MG ECU.

  1. Turn the power switch on (IG).



    A174438E04
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-13 (MRF) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-23 (MRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-21 (MSN) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-20 (MSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-19 (MCS) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-18 (MCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    NOTICE:
    Turning the power switch on (IG) with the MG ECU connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing the inspection.

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-13 (MRF) - B49-23 (MRFG)
    Power switch off
    7.65 to 10.2 Ω
    B49-21 (MSN) - B49-20 (MSNG)
    Power switch off
    12.6 to 16.8 Ω
    B49-19 (MCS) - B49-18 (MCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-13 (MRF) or B49-23 (MRFG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    B49-21 (MSN) or B49-20 (MSNG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    B49-19 (MCS) or B49-18 (MCSG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
Go to step 17
OK


7.CHECK HARNESS AND CONNECTOR (MG ECU - GENERATOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

  1. Turn the power switch on (IG).



    A174438E03
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-12 (GRF) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-22 (GRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-11 (GSN) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-10 (GSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-9 (GCS) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-8 (GCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    NOTICE:
    Turning the power switch on (IG) with the MG ECU connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing the inspection.

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-12 (GRF) - B49-22 (GRFG)
    Power switch off
    7.65 to 10.2 Ω
    B49-11 (GSN) - B49-10 (GSNG)
    Power switch off
    12.6 to 16.8 Ω
    B49-9 (GCS) - B49-8 (GCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-12 (GRF) or B49-22 (GRFG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    B49-11 (GSN) or B49-10 (GSNG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    B49-9 (GCS) or B49-8 (GCSG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
Go to step 19
OK


8.CHECK HARNESS AND CONNECTOR (MG ECU - REAR MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.

  1. Disconnect connector A42 from the MG ECU.

  1. Turn the power switch on (IG).



    A174426E05
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A42-21 (RRF) - Body ground
    Power switch on (IG)
    Below 1 V
    A42-22 (RRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    A42-29 (RSN) - Body ground
    Power switch on (IG)
    Below 1 V
    A42-30 (RSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    A42-11 (RCS) - Body ground
    Power switch on (IG)
    Below 1 V
    A42-23 (RCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    NOTICE:
    Turning the power switch on (IG) with the MG ECU connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing the inspection.

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A42-21 (RRF) - A42-22 (RRFG)
    Power switch off
    7.65 to 10.2 Ω
    A42-29 (RSN) - A42-30 (RSNG)
    Power switch off
    12.6 to 16.8 Ω
    A42-11 (RCS) - A42-23 (RCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A42-21 (RRF) or A42-22 (RRFG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A42-29 (RSN) or A42-30 (RSNG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A42-11 (RCS) or A42-23 (RCSG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
Go to step 21
OK


9.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A174890
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


10.CHECK CONNECTOR CONNECTION CONDITION (REAR MOTOR RESOLVER CONNECTOR)


    A174891
  1. Check the connection of the rear motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


11.CHECK AMOUNT OF GASOLINE
  1. Turn the power switch on (IG).

  1. Check the amount of fuel by referring to the fuel gauge in the meter.

    OK:
    Proper amount of fuel is in the tank.

    HINT:
    1. If the vehicle is driven when there is no fuel in the tank, MG1 will crank the engine but the engine will not start. For this reason, an inoperative condition of MG1 may be detected.
    2. Add fuel until the low fuel level warning light tuns off.



NG
Go to step 25
OK


12.CHECK ENGINE START
  1. Turn the power switch on (READY).

  1. Check if the engine starts.

    HINT:
    Depressing the accelerator pedal with the shift lever in the P position will cause the engine to start.

    Result:
    Result
    Proceed to
    The engine starts.
    A
    The engine does not start.
    B



B
Go to step 15
A


13.CHECK ENGINE IDLING
  1. Leave the vehicle as it is until the engine automatically starts.

    HINT:
    Leaving the vehicle with the A/C switch in the MAX COOL position makes it easier for the engine to start.

  1. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    OK:
    No DTCs are output 1 minute after the engine is started.



NG
GO TO DTC CHART (Click here)
OK


14.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
  1. Remove the inverter with converter assembly (Click here).



    A174889
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

15.CHECK DTC OUTPUT (HV)
  1. Turn the power switch on (IG).

  1. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A94-554 or 555 only is output.
    A
    Other DTCs are output.
    B



B
GO TO DTC CHART (Click here)
A


16.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
  1. Remove the inverter with converter assembly (Click here).



    A174889
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

17.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A174890
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


18.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR RESOLVER)


    A174890
  1. Disconnect the motor resolver connector.



    A174440E05
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B54-1 (MRF) - B54-4 (MRFG)
    Power switch off
    7.65 to 10.2 Ω
    B54-2 (MSN) - B54-5 (MSNG)
    Power switch off
    12.6 to 16.8 Ω
    B54-3 (MCS) - B54-6 (MCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B54-1 (MRF) - B54-2 (MSN)
    Power switch off
    10 MΩ or higher
    B54-1 (MRF) - B54-3 (MCS)
    Power switch off
    10 MΩ or higher
    B54-2 (MSN) - B54-3 (MCS)
    Power switch off
    10 MΩ or higher
    B54-4 (MRFG) - B54-5 (MSNG)
    Power switch off
    10 MΩ or higher
    B54-4 (MRFG) - B54-6 (MCSG)
    Power switch off
    10 MΩ or higher
    B54-5 (MSNG) - B54-6 (MCSG)
    Power switch off
    10 MΩ or higher
    Each terminal listed above - Transaxle housing
    Power switch off
    10 MΩ or higher



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

19.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
  1. Remove the inverter with converter assembly (Click here).



    A174889
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


20.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR RESOLVER)


    A174889
  1. Disconnect the generator resolver connector.



    A174439E02
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B53-1 (GRF) - B53-6 (GRFG)
    Power switch off
    7.65 to 10.2 Ω
    B53-2 (GSN) - B53-7 (GSNG)
    Power switch off
    12.6 to 16.8 Ω
    B53-3 (GCS) - B53-8 (GCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B53-1 (GRF) - B53-2 (GSN)
    Power switch off
    10 MΩ or higher
    B53-1 (GRF) - B53-3 (GCS)
    Power switch off
    10 MΩ or higher
    B53-2 (GSN) - B53-3 (GCS)
    Power switch off
    10 MΩ or higher
    B53-6 (GRFG) - B53-7 (GSNG)
    Power switch off
    10 MΩ or higher
    B53-6 (GRFG) - B53-8 (GCSG)
    Power switch off
    10 MΩ or higher
    B53-7 (GSNG) - B53-8 (GCSG)
    Power switch off
    10 MΩ or higher
    Each terminal listed above - Transaxle housing
    Power switch off
    10 MΩ or higher



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

21.CHECK CONNECTOR CONNECTION CONDITION (REAR MOTOR RESOLVER CONNECTOR)


    A174891
  1. Check the connection of the rear motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


22.CHECK REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY (REAR MOTOR RESOLVER)


    A174891
  1. Disconnect the rear motor resolver connector.



    A174440E06
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    j7-1 (RRF) - j7-4 (RRFG)
    Power switch off
    7.65 to 10.2 Ω
    j7-2 (RSN) - j7-5 (RSNG)
    Power switch off
    12.6 to 16.8 Ω
    j7-3 (RCS) - j7-6 (RCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    j7-1 (RRF) - j7-2 (RSN)
    Power switch off
    10 MΩ or higher
    j7-1 (RRF) - j7-3 (RCS)
    Power switch off
    10 MΩ or higher
    j7-2 (RSN) - j7-3 (RCS)
    Power switch off
    10 MΩ or higher
    j7-4 (RRFG) - j7-5 (RSNG)
    Power switch off
    10 MΩ or higher
    j7-4 (RRFG) - j7-6 (RCSG)
    Power switch off
    10 MΩ or higher
    j7-5 (RSNG) - j7-6 (RCSG)
    Power switch off
    10 MΩ or higher
    Each terminal listed above - Transaxle housing
    Power switch off
    10 MΩ or higher



NG
REPLACE REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR 

23.CHECK NO. 3 FRAME WIRE

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.



    C105715
  1. Disconnect the No. 3 frame wire from the rear traction motor with transaxle assembly.



    A174905E06
  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    U - Body ground and shield ground
    Power switch off
    10 MΩ or higher
    V - Body ground and shield ground
    Power switch off
    10 MΩ or higher
    W - Body ground and shield ground
    Power switch off
    10 MΩ or higher

    NOTICE:
    Wrap the terminals U, V and W of the inverter with converter assembly side No. 3 frame wire (three-phase AC cable for the rear traction motor with transaxle assembly) with the insulating tape to prevent them from shorting to ground.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    U - V
    Power switch off
    10 kΩ or higher
    U - W
    Power switch off
    10 kΩ or higher
    V - W
    Power switch off
    10 kΩ or higher



NG
REPLACE NO. 3 FRAME WIRE (Click here)
OK


24.INSPECT EXTENSION WIRE ASSEMBLY
  1. Remove the rear traction motor with transaxle assembly (Click here).

  1. Remove the extension wire assembly from the rear traction motor with transaxle assembly .



    A174455E01
  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    U - Shield shell
    Power switch off
    10 MΩ or higher
    V - Shield shell
    Power switch off
    10 MΩ or higher
    W - Shield shell
    Power switch off
    10 MΩ or higher

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    U - U
    Power switch off
    Below 1 Ω
    V - V
    Power switch off
    Below 1 Ω
    W - W
    Power switch off
    Below 1 Ω



NG
REPLACE EXTENSION WIRE ASSEMBLY
OK

REPLACE REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY (Click here)  

25.REFUEL VEHICLE

NEXT


26.CHECK ENGINE START
  1. Turn the power switch on (READY).

  1. Check if the engine starts.

    HINT:
    Depressing the accelerator pedal with the shift lever in the P position will cause the engine to start.

    Result:
    Result
    Proceed to
    The engine starts.
    A
    The engine does not start.
    B



B
Go to step 28
A


27.CHECK ENGINE IDLE
  1. Leave the vehicle as it is until the engine automatically starts.

    HINT:
    Leaving the vehicle with the A/C switch in the MAX COOL position makes it easier for the engine to start.

  1. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    OK:
    No DTCs are output 1 minute after the engine is started.



NG
GO TO DTC CHART (Click here)
OK

LEAVE VEHICLE IN P POSITION, AND CHARGE HV BATTERY BY IDLING UNTIL IDLING STOPS 

28.CHECK DTC OUTPUT (HV)
  1. Turn the power switch on (IG).

  1. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A94-554 or 555 only is output.
    A
    Other DTCs are output.
    B



B
GO TO DTC CHART (Click here)
A


29.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
  1. Remove the inverter with converter assembly (Click here).



    A174889
  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)