Home › Power Source / Network › NETWORKING › CAN COMMUNICATION SYSTEM › from 2016.11
RM3160E _57 Power Source / Network _019704 NETWORKING _0095663 CAN COMMUNICATION SYSTEM J

NETWORKING  CAN COMMUNICATION SYSTEM  Open in Bus 2 Main Bus Line  


DESCRIPTION

There may be an open circuit in one of the CAN main bus lines and/or a central gateway ECU (network gateway ECU) branch line when the resistance between terminals 18 (CA4H) and 17 (CA4L) of the central gateway ECU (network gateway ECU) is 70 Ω or higher.

Symptom Trouble Area
Resistance between terminals 18 (CA4H) and 17 (CA4L) of the central gateway ECU (network gateway ECU) is 70 Ω or higher.
·

Central gateway ECU (network gateway ECU) branch lines or connector

·

CAN main bus line or connector

·

ECM

·

Combination meter assembly

·

No. 3 CAN junction connector

·

No. 4 CAN junction connector



This malfunction is not related to the lines of a CAN branch except the central gateway ECU (network gateway ECU) branch lines or to ECUs or sensors connected to a CAN branch.

WIRING DIAGRAM

C367495E02
5.729,5.958 6.188,6.156 0.458,0.198 10 false A43 6.021,5.958 6.479,6.156 0.458,0.198 10 false ECM 6.177,5.281 6.698,5.51 0.521,0.229 10 false 120 Ω 6.177,3.25 6.698,3.479 0.521,0.229 10 false 120 Ω 5.646,4.875 6.26,5.073 0.615,0.198 10 false CANH 5.646,5.448 6.26,5.646 0.615,0.198 10 false CANL 5.354,4.885 5.667,5.083 0.313,0.198 10 false 13 5.365,5.417 5.677,5.615 0.313,0.198 10 false 26 1.885,5.969 2.5,6.167 0.615,0.198 10 false F102 2.271,5.969 4.313,6.208 2.042,0.24 10 false No. 3 CAN Junction Connector 3.656,4.865 3.813,5.063 0.156,0.198 10 false 2 3.615,5.406 3.927,5.604 0.313,0.198 10 false 12 2.635,4.865 2.792,5.063 0.156,0.198 10 false 1 2.604,5.417 2.917,5.615 0.313,0.198 10 false 11 1.906,3.938 2.521,4.135 0.615,0.198 10 false F103 2.281,3.938 4.323,4.177 2.042,0.24 10 false No. 4 CAN Junction Connector 2.635,2.823 2.792,3.021 0.156,0.198 10 false 1 2.604,3.354 2.917,3.552 0.313,0.198 10 false 11 3.625,0.625 3.938,0.823 0.313,0.198 10 false 10 3.635,1.26 3.948,1.458 0.313,0.198 10 false 20 5.292,3.938 5.75,4.135 0.458,0.198 10 false F126 5.646,3.938 6.854,4.438 1.208,0.5 10 false Combination Meter Assembly 5.646,2.854 6.26,3.052 0.615,0.198 10 false CANH 5.656,3.396 6.271,3.594 0.615,0.198 10 false CANL 5.365,2.844 5.677,3.042 0.313,0.198 10 false 28 5.365,3.396 5.677,3.594 0.313,0.198 10 false 27 3.646,2.833 3.802,3.031 0.156,0.198 10 false 8 3.615,3.354 3.927,3.552 0.313,0.198 10 false 18 5.344,0.635 5.656,0.833 0.313,0.198 10 false 18 5.344,1.271 5.656,1.469 0.313,0.198 10 false 17 5.625,0.771 6.24,0.969 0.615,0.198 10 false CA4H 5.635,1.396 6.25,1.594 0.615,0.198 10 false CA4L 4.74,1.729 5.354,1.927 0.615,0.198 10 false F127 5.115,1.729 7.083,2.125 1.969,0.396 10 false Central Gateway ECU (Network Gateway ECU) 0.125,0.115 1.594,0.354 1.469,0.24 12 false for LHD:

C367495E03
5.698,3.927 6.156,4.125 0.458,0.198 10 false A43 6,3.927 6.458,4.125 0.458,0.198 10 false ECM 6.177,5.281 6.698,5.51 0.521,0.229 10 false 120 Ω 6.177,3.25 6.698,3.479 0.521,0.229 10 false 120 Ω 5.646,4.875 6.26,5.073 0.615,0.198 10 false CANH 5.646,5.448 6.26,5.646 0.615,0.198 10 false CANL 5.354,4.885 5.667,5.083 0.313,0.198 10 false 28 5.365,5.417 5.677,5.615 0.313,0.198 10 false 27 1.854,3.927 2.469,4.125 0.615,0.198 10 false F102 2.229,3.927 4.271,4.167 2.042,0.24 10 false No. 3 CAN Junction Connector 3.656,4.865 3.813,5.063 0.156,0.198 10 false 8 3.615,5.406 3.927,5.604 0.313,0.198 10 false 18 2.635,4.865 2.792,5.063 0.156,0.198 10 false 1 2.604,5.417 2.917,5.615 0.313,0.198 10 false 11 1.875,5.969 2.49,6.167 0.615,0.198 10 false F103 2.25,5.969 4.292,6.208 2.042,0.24 10 false No. 4 CAN Junction Connector 2.635,2.823 2.792,3.021 0.156,0.198 10 false 1 2.604,3.354 2.917,3.552 0.313,0.198 10 false 11 3.625,0.625 3.938,0.823 0.313,0.198 10 false 10 3.635,1.26 3.948,1.458 0.313,0.198 10 false 20 5.219,5.958 5.677,6.156 0.458,0.198 10 false F126 5.604,5.958 6.813,6.458 1.208,0.5 10 false Combination Meter Assembly 5.646,2.854 6.26,3.052 0.615,0.198 10 false CANH 5.656,3.396 6.271,3.594 0.615,0.198 10 false CANL 5.365,2.844 5.677,3.042 0.313,0.198 10 false 13 5.365,3.396 5.677,3.594 0.313,0.198 10 false 26 3.646,2.833 3.802,3.031 0.156,0.198 10 false 2 3.615,3.354 3.927,3.552 0.313,0.198 10 false 12 5.344,0.635 5.656,0.833 0.313,0.198 10 false 18 5.344,1.271 5.656,1.469 0.313,0.198 10 false 17 5.625,0.771 6.24,0.969 0.615,0.198 10 false CA4H 5.635,1.396 6.25,1.594 0.615,0.198 10 false CA4L 4.74,1.729 5.354,1.927 0.615,0.198 10 false F127 5.115,1.729 7.083,2.125 1.969,0.396 10 false Central Gateway ECU (Network Gateway ECU) 0.125,0.115 1.594,0.354 1.469,0.24 12 false for RHD:

CAUTION / NOTICE / HINT

NOTICE:
·

Because the order of diagnosis is important to allow correct diagnosis, make sure to begin troubleshooting using How to Proceed with Troubleshooting when CAN communication system related DTCs are output.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING

·

Before measuring the resistance of the CAN bus, turn the ignition switch off and leave the vehicle for 1 minute or more without operating the key or any switches, or opening or closing the doors. After that, disconnect the cable from the negative (-) battery terminal and leave the vehicle for 1 minute or more before measuring the resistance.

·

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notices before proceeding with work.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

After performing repairs, perform the DTC check procedure and confirm that the DTCs are not output again.

DTC check procedure: Turn the ignition switch to ON and wait at least 60 seconds, and then drive the vehicle at a speed of 60 km/h (37 mph) or more for 9 seconds or more.

·

After the repair, perform the CAN bus check and check that all the ECUs and sensors connected to the CAN communication system are displayed.

Click herePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>DIAGNOSIS SYSTEM



HINT:
·

Before disconnecting related connectors for inspection, push in on each connector body to check that the connector is not loose or disconnected.

·

When a connector is disconnected, check that the terminals and connector body are not cracked, deformed or corroded.



PROCEDURE

1.CHECK FOR OPEN IN CAN BUS LINES (CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU))
a.

Disconnect the cable from the negative (-) battery terminal.


b.

Disconnect the F127 central gateway ECU (network gateway ECU) connector.


c.
C334701C90
1.438,0.094 1.927,0.323 0.49,0.229 1.979,1.813 1.792,1.813 1.792,1.813 1.792,1.188 true 1.448,1.813 1.656,1.813 1.656,1.813 1.656,1.188 true 1.531,0.125 2.146,0.323 0.615,0.198 10 false F127 0.156,0.104 0.771,0.302 0.615,0.198 10 false *a 1.094,1.74 1.521,1.948 0.427,0.208 10 false CA4L 2.021,1.729 2.448,1.938 0.427,0.208 10 false CA4H
*a Front view of wire harness connector
(to Central Gateway ECU (Network Gateway ECU))


Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F127-18 (CA4H) - F127-17 (CA4L) Cable disconnected from negative (-) battery terminal 108 to 132 Ω



Result:
Result
OK
NG



OK

2.CHECK FOR OPEN IN CAN BUS LINES (COMBINATION METER ASSEMBLY - NO. 4 CAN JUNCTION CONNECTOR)

NG

REPAIR OR REPLACE CAN BRANCH BUS LINES CONNECTED TO CENTRAL GATEWAY ECU (NETWORK GATEWAY ECU)

2.CHECK FOR OPEN IN CAN BUS LINES (COMBINATION METER ASSEMBLY - NO. 4 CAN JUNCTION CONNECTOR)
a.
C301172C81
0.677,0.385 1.135,0.635 0.458,0.25 1.427,1.635 1.594,2 1.594,2 1.833,2 true 1.313,1.615 1.146,2 1.146,2 0.948,2 true 0.083,0.094 0.396,0.292 0.313,0.198 10 false *a 0.75,0.427 1.25,0.656 0.5,0.229 10 false F126 0.563,1.917 1.188,2.094 0.625,0.177 10 false CANL 1.896,1.917 2.51,2.115 0.615,0.198 10 false CANH
*a Front view of wire harness connector
(to Combination Meter Assembly)


Disconnect the F126 combination meter assembly connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
F126-28 (CANH) - F126-27 (CANL) Cable disconnected from negative (-) battery terminal 108 to 132 Ω



Result:
Result
OK
NG



OK

REPLACE COMBINATION METER ASSEMBLY

NG

3.CHECK FOR OPEN IN CAN BUS LINES (ECM - NO. 3 CAN JUNCTION CONNECTOR)
3.CHECK FOR OPEN IN CAN BUS LINES (ECM - NO. 3 CAN JUNCTION CONNECTOR)
a.

Reconnect the F126 combination meter assembly connector.


b.
C292333C02
1.583,0.167 1.979,0.469 0.396,0.302 2.635,1 2.76,0.229 2.76,0.229 2.833,0.229 true 2.927,1.927 2.844,1.927 2.844,1.927 2.625,1.094 true 0.052,0.063 0.365,0.26 0.313,0.198 10 false *a 1.656,0.208 2.115,0.406 0.458,0.198 10 false A43 2.906,0.125 3.365,0.354 0.458,0.229 10 false CANH 2.979,1.833 3.396,2.052 0.417,0.219 10 false CANL
*a Front view of wire harness connector
(to ECM)


Disconnect the A43 ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A43-13 (CANH) - A43-26 (CANL) Cable disconnected from negative (-) battery terminal 108 to 132 Ω



Result:
Result Proceed to
OK (for 1AR-FE) A
OK (for 2GR-FKS) B
NG C



A

B

C

4.CHECK FOR OPEN IN CAN BUS LINES (NO. 3 CAN JUNCTION CONNECTOR)
4.CHECK FOR OPEN IN CAN BUS LINES (NO. 3 CAN JUNCTION CONNECTOR)
a.

Reconnect the A43 ECM connector.


b.
C292410C01
1.531,0.198 2,0.521 0.469,0.323 0.531,2.01 0.76,0.573 0.76,0.573 0.844,0.573 true 0.792,2.021 0.969,0.854 0.969,0.854 1.073,0.854 true 0.99,3.188 0.802,3.188 0.802,3.188 0.531,2.219 true 1.24,2.781 1.115,2.781 1.115,2.781 0.802,2.229 true 0.063,0.063 0.375,0.26 0.313,0.198 10 false *a 1.615,0.25 2.021,0.469 0.406,0.219 10 false F102 0.906,0.469 1.521,0.667 0.615,0.198 10 false CANH*b 1.146,0.75 1.76,0.948 0.615,0.198 10 false CANH*c 1.073,3.083 1.99,3.281 0.917,0.198 10 false CANL*b 1.323,2.688 2.24,2.885 0.917,0.198 10 false CANL*c
*a Front view of wire harness connector
(to No. 3 CAN Junction Connector)
*b to No. 4 CAN Junction Connector
*c to ECM


Disconnect the F102 No. 3 CAN junction connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition Connected to
F102-1 (CANH) - F102-11 (CANL) Cable disconnected from negative (-) battery terminal 108 to 132 Ω No. 4 CAN junction connector
F102-2 (CANH) - F102-12 (CANL) Cable disconnected from negative (-) battery terminal 108 to 132 Ω ECM



Result:
Result Proceed to
OK A
NG (ECM main line) B
NG (No. 4 CAN junction connector main line) C



A

REPLACE NO. 3 CAN JUNCTION CONNECTOR

B

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (ECM - NO. 3 CAN JUNCTION CONNECTOR)

C

5.CHECK FOR OPEN IN CAN BUS LINES (NO. 4 CAN JUNCTION CONNECTOR)
5.CHECK FOR OPEN IN CAN BUS LINES (NO. 4 CAN JUNCTION CONNECTOR)
a.

Reconnect the F102 No. 3 CAN junction connector.


b.
C292410C02
1.49,0.198 1.917,0.531 0.427,0.333 0.531,2.01 0.76,0.573 0.76,0.573 0.844,0.573 true 2.365,2 2.542,0.833 2.542,0.833 2.646,0.833 true 0.99,3.188 0.802,3.188 0.802,3.188 0.531,2.219 true 2.615,2.854 2.521,2.854 2.521,2.854 2.396,2.24 true 0.063,0.063 0.375,0.26 0.313,0.198 10 false *a 1.563,0.25 1.99,0.469 0.427,0.219 10 false F103 0.906,0.469 1.521,0.667 0.615,0.198 10 false CANH*b 2.729,0.74 3.344,0.938 0.615,0.198 10 false CANH*c 1.073,3.083 1.99,3.281 0.917,0.198 10 false CANL*b 2.698,2.76 3.26,3.031 0.563,0.271 10 false CANL*c
*a Front view of wire harness connector
(to No. 4 CAN Junction Connector)
*b to No. 3 CAN Junction Connector
*c to Combination Meter Assembly


Disconnect the F103 No. 4 CAN junction connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition Connected to
F103-1 (CANH) - F103-11 (CANL) Cable disconnected from negative (-) battery terminal 108 to 132 Ω No. 3 CAN junction connector
F103-8 (CANH) - F103-18 (CANL) Cable disconnected from negative (-) battery terminal 108 to 132 Ω Combination meter assembly



Result:
Result Proceed to
OK A
NG (Combination meter assembly main line) B
NG (No. 3 CAN junction connector main line) C



A

REPLACE NO. 4 CAN JUNCTION CONNECTOR

B

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (COMBINATION METER ASSEMBLY - NO. 4 CAN JUNCTION CONNECTOR)

C

REPAIR OR REPLACE CAN MAIN BUS LINE OR CONNECTOR (NO. 3 CAN JUNCTION CONNECTOR - NO. 4 CAN JUNCTION CONNECTOR)