Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › REAR MOTOR GENERATOR CONTROL SYSTEM
RM37A0E _51 Engine / Hybrid System _086850 HYBRID / BATTERY CONTROL _0420997 REAR MOTOR GENERATOR CONTROL SYSTEM S

HYBRID / BATTERY CONTROL  REAR MOTOR GENERATOR CONTROL SYSTEM  DIAGNOSTIC TROUBLE CODE CHART  


Rear Motor Generator Control System
DTC No. Detection Item MIL Warning Indicate Link
P0A4516 Drive Motor "B" Position Sensor Circuit Voltage Below Threshold Comes on Master Warning:
Comes on
Click here
P0A451F Drive Motor "B" Position Sensor Circuit Intermittent Does not come on Master Warning:
Does not come on
Click here
P0A4521 Drive Motor "B" Position Sensor Signal Amplitude < Minimum Comes on Master Warning:
Comes on
Click here
P0A4522 Drive Motor "B" Position Sensor Signal Amplitude > Maximum Comes on Master Warning:
Comes on
Click here
P0A6912 Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Battery Does not come on Master Warning:
Comes on
Click here
P0A6914 Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Ground or Open Does not come on Master Warning:
Comes on
Click here
P0A691C Drive Motor "B" Phase V Current(High Resolution) Circuit Voltage Out of Range Does not come on Master Warning:
Comes on
Click here
P0A691F Drive Motor "B" Phase V Current(High Resolution) Circuit Intermittent Does not come on Master Warning:
Does not come on
Click here
P0A6C12 Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery Does not come on Master Warning:
Comes on
Click here
P0A6C14 Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open Does not come on Master Warning:
Comes on
Click here
P0A6C1C Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range Does not come on Master Warning:
Comes on
Click here
P0A6C1F Drive Motor "B" Phase W Current(High Resolution) Circuit Intermittent Does not come on Master Warning:
Does not come on
Click here
P0A7972 Drive Motor "B" Inverter Actuator Stuck Open Comes on Master Warning:
Comes on
Click here
P0A7973 Drive Motor "B" Inverter Actuator Stuck Closed Comes on Master Warning:
Comes on
Click here
P0A799E Drive Motor "B" Inverter Stuck On Comes on Master Warning:
Comes on
Click here
P0A9100 Drive Motor "B" Performance Comes on Master Warning:
Comes on
Click here
P0AF211 Drive Motor Inverter Temperature Sensor "B" Circuit Short to Ground Comes on Master Warning:
Comes on
Click here
P0AF215 Drive Motor Inverter Temperature Sensor "B" Circuit Short to Battery or Open Comes on Master Warning:
Comes on
Click here
P0AF21C Drive Motor Inverter Temperature Sensor "B" Circuit Voltage Out of Range Comes on Master Warning:
Comes on
Click here
P0BF112 Drive Motor "B" Phase U Current Sensor Circuit Short to Battery Comes on Master Warning:
Comes on
Click here
P0BF114 Drive Motor "B" Phase U Current Sensor Circuit Short to Ground or Open Comes on Master Warning:
Comes on
Click here
P0BF11F Drive Motor "B" Phase U Current Sensor Circuit Intermittent Does not come on Master Warning:
Does not come on
Click here
P0BF128 Drive Motor "B" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning:
Comes on
Click here
P0BF512 Drive Motor "B" Phase V Current Sensor Circuit Short to Battery Comes on Master Warning:
Comes on
Click here
P0BF514 Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open Comes on Master Warning:
Comes on
Click here
P0BF51F Drive Motor "B" Phase V Current Sensor Circuit Intermittent Does not come on Master Warning:
Does not come on
Click here
P0BF528 Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning:
Comes on
Click here
P0BF912 Drive Motor "B" Phase W Current Sensor Circuit Short to Battery Comes on Master Warning:
Comes on
Click here
P0BF914 Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open Comes on Master Warning:
Comes on
Click here
P0BF91F Drive Motor "B" Phase W Current Sensor Circuit Intermittent Does not come on Master Warning:
Does not come on
Click here
P0BF928 Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Comes on Master Warning:
Comes on
Click here
P0BFE62 Drive Motor "B" Phase U-V-W Current Sensor Signal Compare Failure Comes on Master Warning:
Comes on
Click here
P0C021D Drive Motor "B" System Circuit Current Out of Range Comes on Master Warning:
Comes on
Click here
P0C1A00 Drive Motor "B" Execution Torque Performance Comes on Master Warning:
Comes on
Click here
P0C5513 Drive Motor "B" Position Sensor Circuit "A" Circuit Open Comes on Master Warning:
Comes on
Click here
P0C5516 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold Comes on Master Warning:
Comes on
Click here
P0C5517 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold Comes on Master Warning:
Comes on
Click here
P0C551F Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent Does not come on Master Warning:
Does not come on
Click here
P0C5F13 Drive Motor "B" Position Sensor Circuit "B" Circuit Open Comes on Master Warning:
Comes on
Click here
P0C5F16 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold Comes on Master Warning:
Comes on
Click here
P0C5F17 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold Comes on Master Warning:
Comes on
Click here
P0C5F1F Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent Does not come on Master Warning:
Does not come on
Click here
P1BF946 Internal Control Module (EEPROM Estimated Temperature Information) Calibration / Parameter Memory Failure Does not come on Master Warning:
Comes on
Click here
P1BFA46 Internal Control Module (EEPROM Resolver Learning Value) Calibration / Parameter Memory Failure Comes on Master Warning:
Comes on
Click here
P1C2C1C Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range Comes on Master Warning:
Comes on
Click here
P1C2C49 Drive Motor "B" Control Module AD Converter Circuit Internal Electronic Failure Comes on Master Warning:
Comes on
Click here
P1C5E19 Drive Motor "B" Inverter Circuit Current Above Threshold Comes on Master Warning:
Comes on
Click here
P1C631F Drive Motor "B" Control Module Offset Power Circuit Intermittent Does not come on Master Warning:
Does not come on
Click here
P1C661F Drive Motor "B" Control Module Circuit Intermittent Does not come on Master Warning:
Does not come on
Click here
P1C681F Drive Motor "B" Phase U-V-W Current Sensor Circuit Intermittent Does not come on Master Warning:
Does not come on
Click here
P1CAE49 Drive Motor "B" Position Sensor Internal Electronic Failure Comes on Master Warning:
Comes on
Click here
P1CB138 Drive Motor "B" Position Sensor REF Signal Frequency Incorrect Comes on Master Warning:
Comes on
Click here
P262C1C Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range Comes on Master Warning:
Comes on
Click here
P310B1F Communication Error from Drive Motor "A" to Drive Motor "B" Circuit Intermittent Does not come on Master Warning:
Does not come on
Click here
P310B83 Communication Error from Drive Motor "A" to Drive Motor "B" Value of Signal Protection Calculation Incorrect Comes on Master Warning:
Comes on
Click here
P310B86 Communication Error from Drive Motor "A" to Drive Motor "B" Signal (Some Circuit Quantity, Reported via Serial Data) Invalid Comes on Master Warning:
Comes on
Click here
P310B87 Communication Error from Drive Motor "A" to Drive Motor "B" Missing Message Comes on Master Warning:
Comes on
Click here
P32CF1F Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Circuit Intermittent Does not come on Master Warning:
Does not come on
Click here
P32CF83 Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Value of Signal Protection Calculation Incorrect Comes on Master Warning:
Comes on
Click here
P32CF86 Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Signal (Some Circuit Quantity, Reported via Serial Data) Invalid Comes on Master Warning:
Comes on
Click here
P32CF87 Lost Communication between Drive Motor "A" and "B" (Drive Motor "B") Missing Message Comes on Master Warning:
Comes on
Click here