P0100 Mass or Volume Air Flow Circuit
Diagnostic trouble codes · Vehicles built Jun 2011 – Jul 2012
Also covers:
- P0102 Mass Air Flow Circuit Low
- P0103 Mass Air Flow Circuit High
DESCRIPTION
The mass air flow meter uses a platinum hot wire. The mass air flow meter consists of a platinum hot wire, a temperature sensor and a control circuit installed in a plastic housing. The mass air flow meter works on the principle that the hot wire and temperature sensor located in the intake air by-pass of the housing detect any changes in the intake air temperature.The hot wire is maintained at the predetermined temperature by controlling the current flow through the hot wire. This current flow is then related as the output voltage of the mass air flow meter.
The circuit is constructed so that the platinum hot wire and temperature sensor provide a bridge circuit, with the power transistor controlled so that the potential of A and B remains equal to maintain the predetermined temperature.


| DTC No. |
DTC Detection Condition |
Trouble Area |
| P0100 |
Open or short in mass air flow meter circuit for more than 3 seconds with engine speed at 2,000 rpm or less (1 trip detection logic) |
|
| P0102 |
Open in mass air flow meter circuit for more than 3 seconds with engine speed at 2,000 rpm or less (1 trip detection logic) |
|
| P0103 |
Short in mass air flow meter circuit for more than 3 seconds with engine speed at 2,000 rpm or less (1 trip detection logic) |
- HINT:
- After confirming DTC P0100, P0102 or P0103, check the mass air flow ratio in the following menus: Powertrain / Engine / Data List / MAF using the intelligent tester.
- Reference:
Air Flow Value (gm/sec.)
Malfunction
Approximately 0.0
- Open in mass air flow meter power source circuit
- Open or short in VG circuit
174.0 or more
Open in EVG circuit
- Open in mass air flow meter power source circuit
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
- HINT:
- Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
| 1. READ VALUE USING INTELLIGENT TESTER (MAF) |
Connect the intelligent tester to the DLC3.
Start the engine and turn the tester ON.
Enter the following menus: Powertrain / Engine / Data List / MAF
Read the value.
- Result:
Air flow rate (gm/sec.)
Proceed to
0.0
A
174.0 or more
B
Between 1 and 173.0
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT MASS AIR FLOW METER (POWER SOURCE CIRCUIT) |
Disconnect the A4 mass air flow meter connector.
Turn the ignition switch ON.

Measure the voltage of the wire harness side connector and the body ground.
- Standard voltage:
Tester Connection
Specified Condition
+B (A4-1) - Body ground
11 to 14 V
|
|
||||
| OK | |
| 3. INSPECT ECM (VG VOLTAGE) |
Start the engine.

Measure the voltage of the ECM connector.
- HINT:
- The A/C switch should be turned OFF.
- Standard voltage:
Tester Connection
Condition
Specified Condition
VG (E7-24) - EVG (E7-32)
Engine is idling
0.5 to 3.4 V
|
|
||||
| NG | |
| 4. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the A4 mass air flow meter connector.

Disconnect the E7 ECM connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance (Check for open):
Tester Connection
Specified Condition
VG (A4-3) - VG (E7-24)
Below 1 Ω
E2G (A4-2) - EVG (E7-32)
Below 1 Ω
- Standard resistance (Check for short):
Tester Connection
Specified Condition
VG (A4-3) or VG (E7-24) - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 5. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - INTEGRATION RELAY) |
![]() ![]() |
Disconnect the A4 MAF meter connector.
Remove the integration relay from the engine room junction block (Click here).
Disconnect the 1J integration relay connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance (Check for open):
Tester Connection
Specified Condition
+B (A4-1) - 1J-5
Below 1 Ω
- Standard resistance (Check for short):
Tester Connection
Specified Condition
+B (A4-1) or 1J-5 - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||
| 6. INSPECT ECM (SENSOR GROUND) |
Measure the resistance of the ECM connector and body ground.

- Standard resistance:
Tester Connection
Specified Condition
EVG (E7-32) - Body ground
Below 1 Ω
|
|
||||
| OK | |
| 7. CHECK HARNESS AND CONNECTOR (MASS AIR FLOW METER - ECM) |
Disconnect the A4 mass air flow meter connector.

Disconnect the E7 ECM connector.
Measure the resistance of the wire harness side connectors.
- Standard resistance (Check for open):
Tester Connection
Specified Condition
VG (A4-3) - VG (E7-24)
Below 1 Ω
E2G (A4-2) - EVG (E7-32)
Below 1 Ω
- Standard resistance (Check for short):
Tester Connection
Specified Condition
VG (A4-3) or VG (E7-24) - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||