2014 Hilux · Service Manual ENGINE

P0400 Exhaust Gas Recirculation Flow

Diagnostic trouble codes · Vehicles built Jun 2011 – Jul 2012

Versions by build date: Jun 2011 – Jul 2012 Aug 2012 – Jul 2013 Aug 2013 – Jul 2014 from Aug 2014

DESCRIPTION

The EGR system recirculates exhaust gases, in order to suit every driving condition. The recirculated gas mingles with intake air, therefore the EGR system can slow combustion speed and keep the combustion temperature down. This helps reduce NOx emission.
In order to increase EGR circulation efficiency, the ECM adjusts the lift amount of the EGR valve and throttle valve angle.
DTC No.
DTC Detection Condition
Trouble Area
P0400
When either condition below is met:
  1. Target and actual positions of the EGR valve are different
    (1 trip detection logic)
  2. Mass air flow rate is not changed when turning on EGR valve
    (2 trip detection logic)
  1. EGR valve stuck
  2. EGR valve does not move smoothly
  3. E-VRV (for E-EGR)
  4. VSV (for EGR Cut)
  5. E-VRV (for E-EGR) circuit
  6. VSV (for EGR Cut) circuit
  7. EGR blockage in line between exhaust manifold and intake manifold
  8. ECM

MONITOR DESCRIPTION

  1. If the EGR valve is forcibly operated but the intake air amount does not vary, the ECM determines that the EGR valve is malfunctioning. The ECM then illuminates the MIL.
  2. When the target and actual positions of the EGR valve are different, the ECM interprets this as a malfunction of the EGR valve and illuminates the MIL.

WIRING DIAGRAM

A155686E01

INSPECTION PROCEDURE

NOTICE:
After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).

HINT:
  1. Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can help determine if the vehicle was running or stopped, if the engine was warmed up or not, and other data from the time the malfunction occurred.
  2. After warming up the engine, DTC P0400 can be set if 1 second or more passes after quickly accelerating the engine from idling.


1. CHECK OTHER DTC OUTPUT (IN ADDITION TO DTC P0400)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch ON and turn the tester ON.

  1. Enter the following menus: Powertrain / Engine / DTC.

  1. Read DTCs.

    Result:
    Display (DTC Output)
    Proceed to
    P0400
    A
    P0400 and P0405 and/or P0406
    B

    HINT:
    If codes other than P0400 are output, perform troubleshooting for those DTCs first.



B
GO TO DTC CHART (Click here)
A


2. CHECK VACUUM PUMP ASSEMBLY
  1. Check the negative pressure of the vacuum pump.

    Standard:
    More than 86.7 kPa (650 mmHg, 26 in.Hg)



NG
REPLACE VACUUM PUMP ASSEMBLY
OK


3. CHECK VACUUM HOSES
  1. Check the vacuum hoses.

    OK:
    The hoses are not damaged and securely connected.



NG
REPAIR OR REPLACE VACUUM HOSE
OK


4. INSPECT ELECTRIC VACUUM REGULATING VALVE (FOR E-EGR)
A155057E01
  1. Disconnect the vacuum hose to the EGR valve.

  1. Connect the vacuum gauge.

  1. Connect the intelligent tester to the DLC3.

  1. Start the engine.

  1. Warm up the engine.

    HINT:
    The engine coolant temperature is 80°C (176°F) or more.

  1. Enter the following menus: Powertrain / Engine / Active Test / Control the EGR system.

  1. Check the vacuum change when the Active Test is used to turn the E-VRV (for E-EGR) from OFF to ON.

    Result:
    Active Test
    Vacuum gauge
    Proceed to
    OFF to ON
    Changes from above 28 kPa (210 mmHg, 8.3 in.Hg) to 0 kPa (0 mmHg, 0 in.Hg)
    A
    Stays at 0 kPa (0 mmHg, 0 in.Hg), or stays above 28 kPa (210 mmHg, 8.3 in.Hg)
    B



B
Go to step 8
A


5. INSPECT NO. 1 VACUUM SWITCHING VALVE (FOR EGR CUT)
A155058E01
  1. Using a 3-way connector, connect a vacuum gauge to the hose between the VSV (for EGR Cut) and EGR valve.

  1. Connect the intelligent tester to the DLC3.

  1. Start the engine and turn the tester ON.

  1. Enter the following menus: Powertrain / Engine / Active Test / Activate the VSV for EGR Cut.

  1. Check the vacuum change when the Active Test is used to turn the E-VRV (for E-EGR) from OFF to ON.

    Result:
    Active Test
    Vacuum gauge
    Proceed to
    OFF to ON
    Changes from above 28 kPa (210 mmHg, 8.3 in.Hg) to 0 kPa (0 mmHg, 0 in.Hg)
    A
    Stays at 0 kPa (0 mmHg, 0 in.Hg), or stays above 28 kPa (210 mmHg, 8.3 in.Hg)
    B



B
Go to step 11
A


6. INSPECT ELECTRIC EGR CONTROL VALVE ASSEMBLY
  1. Inspect the electric EGR control valve assembly (Click here).

    OK:
    The valve is not stuck and does not have heavy carbon deposits.



NG
REPLACE EGR CONTROL VALVE ASSEMBLY (Click here)
OK


7. CHECK FOR BLOCKAGE IN EGR GAS PASSAGE (EXHAUST MANIFOLD - ELECTRIC EGR CONTROL VALVE)
  1. Check for blockage in the EGR gas passage between the exhaust manifold and electric EGR control valve assembly.

OK:
No blockage in the EGR gas passage

HINT:
When performing the check for deposits check the interior of the EGR valve, EGR pipe, EGR cooler, EGR cooler bypass valve and the entire EGR passage.



NG
REPAIR OR REPLACE MALFUNCTIONING PARTS, COMPONENT AND AREA
OK

REPLACE ECM (Click here)

8. INSPECT ELECTRIC VACUUM REGULATING VALVE (E-VRV FOR E-EGR)

  1. A093008E11
    Disconnect the V1 E-VRV for E-EGR connector.

  1. Measure the resistance of the E-VRV for E-EGR.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    11 to 13 Ω



NG
REPLACE EGR CONTROL VALVE ASSEMBLY (Click here)
OK


9. CHECK HARNESS AND CONNECTOR (E-VRV FOR E-EGR - ECM)

  1. A099854E12
    Disconnect the V1 E-VRV for E-EGR connector.

  1. Disconnect the E7 ECM connector.

  1. Measure the resistance of the wire harness side connector.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    V1-2 - EGR (E7-9)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    V1-2 or EGR (E7-9) - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


10. CHECK HARNESS AND CONNECTOR (E-VRV FOR E-EGR - INTEGRATION RELAY)
G034910E06
  1. Remove the integration relay from the engine room junction block (Click here).

  1. Disconnect the 1J integration relay connector.

  1. Disconnect the V1 E-VRV for E-EGR connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    1J-5 - V1-1
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    1J-5 or V1-1 - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)

11. INSPECT NO. 1 VACUUM SWITCHING VALVE FOR EGR CUT (RESISTANCE)

  1. A099241E02
    Disconnect the V2 VSV for EGR cut connector.

  1. Measure the resistance of the VSV for EGR Cut.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    37 to 44 Ω



NG
REPLACE NO. 1 VACUUM SWITCHING VALVE FOR EGR CUT (Click here)
OK


12. CHECK HARNESS AND CONNECTOR (NO. 1 VACUUM SWITCHING VALVE FOR EGR CUT - ECM)

  1. A155124E05
    Disconnect the V2 VSV for EGR Cut connector.

  1. Disconnect the E7 ECM connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    EGRC (E7-18) - V2-2
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    EGRC (E7-18) or V2-2 - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


13. CHECK HARNESS AND CONNECTOR (VSV FOR EGR CUT - INTEGRATION RELAY)
G035727E03
  1. Remove the integration relay from the engine room junction block (Click here ).

  1. Disconnect the 1J integration relay connector.

  1. Disconnect the V2 VSV for EGR cut connector.

  1. Measure the resistance of the wire harness side connectors.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    1J-5 - V2-1
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    1J-5 or V2-1 - Body ground
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)


← P0340 Camshaft Position Sensor "A" Circuit (Bank 1 or Single Sensor) (from Aug 2014)P0400 Exhaust Gas Recirculation Flow (Aug 2012 – Jul 2013) →