Home › Engine / Hybrid System › 2TR-FE ENGINE CONTROL › SFI SYSTEM(w/ Secondary Air Injection System) › from 2012.10
RM1840EF _51 Engine / Hybrid System _009569 2TR-FE ENGINE CONTROL _0052076 SFI SYSTEM(w/ Secondary Air Injection System) C

2TR-FE ENGINE CONTROL  SFI SYSTEM(w/ Secondary Air Injection System)  P0136  Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2)  P0137  Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2)  P0138  Oxygen Sensor Circuit High Voltage (Bank 1 Sensor 2)  


DESCRIPTION

In order to obtain a high purification rate of the carbon monoxide (CO), hydrocarbon (HC) and nitrogen oxide (NOx) components in the exhaust gas, a Three-way Catalytic Converter (TWC) is used. For the most efficient use of the Three-way Catalytic Converter (TWC), the air-fuel ratio must be precisely controlled so that it is always close to the stoichiometric air-fuel ratio. For the purpose of helping the ECM to deliver accurate air-fuel ratio control, a heated oxygen sensor is used.

The heated oxygen sensor is located behind the Three-way Catalytic Converter (TWC), and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with a heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).

When the air-fuel ratio becomes lean, the oxygen concentration in the exhaust gas is rich. The heated oxygen sensor informs the ECM that the post-Three-way Catalytic Converter (TWC) air-fuel ratio is lean (low voltage, i.e. below 0.45 V).

Conversely, when the air-fuel ratio is richer than the stoichiometric air-fuel ratio, the oxygen concentration in the exhaust gas becomes lean. The heated oxygen sensor informs the ECM that the post-Three-way Catalytic Converter (TWC) air-fuel ratio is rich (high voltage, i.e. higher than 0.45 V). The heated oxygen sensor has the property of changing its output voltage drastically when the air-fuel ratio is close to the stoichiometric level.

The ECM uses the supplementary information from the heated oxygen sensor to determine whether the air-fuel ratio after the Three-way Catalytic Converter (TWC) is rich or lean, and adjusts the fuel injection time accordingly. Thus, if the heated oxygen sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in primary air-fuel ratio control.

A301838
1.063,2.74 1.323,2.74 false 3.146,1.198 3.406,1.198 false 2.719,1.885 3.146,1.583 3.146,1.583 3.25,1.583 false 1.354,2.656 2.125,2.854 0.771,0.198 10 false Cover 1.927,3.063 2.958,3.323 1.031,0.26 10 false Exhaust Gas 2.844,0.219 3.875,0.479 1.031,0.26 10 false Atmospheric Air 3.458,1.115 4.115,1.365 0.656,0.25 10 false Housing 3.302,1.51 4.448,1.719 1.146,0.208 10 false Solid Electrolyte 3.302,1.76 4.583,2.042 1.281,0.281 10 false (Zirconia Element) 3.292,2.021 4.646,2.271 1.354,0.25 10 false Platinum Electrode 3.281,2.281 3.885,2.51 0.604,0.229 10 false Heater 3.281,2.542 4.635,2.792 1.354,0.25 10 false Coating (Ceramic) 4.313,0.833 5.313,1.083 1,0.25 10 false Output Voltage 5.188,0.583 6.594,0.823 1.406,0.24 10 false Ideal Air-fuel Mixture 4.802,2.802 6.76,3.063 1.958,0.26 10 false Richer - Air-fuel Ratio - Leaner

DTC No. Detection Item INF Code DTC Detection Condition MIL Memory
P0136 Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2) Abnormal voltage output:
During active air-fuel ratio control, the following conditions (a) and (b) are met for a certain period of time (2 trip detection logic):

(a) Heated oxygen sensor voltage does not increase to higher than 0.59 V.

(b) Heated oxygen sensor voltage does not decrease to below 0.21 V.


·

Open or short in heated oxygen sensor circuit

·

Heated oxygen sensor

·

Heated oxygen sensor heater

·

Air fuel ratio sensor

·

Integration relay

·

Gas leak from exhaust system


Comes on DTC stored
P0137 Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2) Low voltage (open):
During active air-fuel ratio control, the following conditions (a) and (b) are met for a certain period of time (2 trip detection logic):

(a) Heated oxygen sensor voltage output is below 0.21 V.

(b) Target air-fuel ratio is rich.


·

Open in heated oxygen sensor circuit

·

Heated oxygen sensor

·

Heated oxygen sensor heater

·

Air fuel ratio sensor

·

Integration relay

·

Gas leak from exhaust system


Comes on DTC stored
P0138 Oxygen Sensor Circuit High Voltage (Bank 1 Sensor 2) High voltage (short):
During active air-fuel ratio control, the following conditions (a) and (b) are met for a certain period of time (2 trip detection logic):

(a) Heated oxygen sensor voltage output is higher than 0.59 V.

(b) Target air-fuel ratio is lean.


·

Short in heated oxygen sensor circuit

·

Heated oxygen sensor

·

Air fuel ratio sensor

·

ECM


Comes on DTC stored

MONITOR DESCRIPTION

Active Air-fuel Ratio Control

The ECM usually performs air-fuel ratio feedback control so that the air fuel ratio sensor output indicates a near stoichiometric air-fuel ratio. This vehicle includes active air-fuel ratio control in addition to regular air-fuel ratio control. The ECM performs active air-fuel ratio control to detect any deterioration in the Three-way Catalytic Converter (TWC) and heated oxygen sensor malfunctions (refer to the diagram below).

Active air-fuel ratio control is performed for approximately 15 to 20 seconds while driving with a warm engine. During active air-fuel ratio control, the air-fuel ratio is forcibly regulated to become lean or rich by the ECM. If the ECM detects a malfunction, a DTC is stored.


Abnormal Voltage Output of Heated Oxygen Sensor (DTC P0136)

While the ECM is performing active air-fuel ratio control, the air-fuel ratio is forcibly regulated to become rich or lean. If the sensor is not functioning properly, the voltage output variation is small. For example, when the heated oxygen sensor voltage does not decrease to below 0.21 V and does not increase to higher than 0.59 V during active air-fuel ratio control, the ECM determines that the sensor voltage output is abnormal and stores DTC P0136.

A115540
3.281,1.635 3.073,1.354 false 3.313,1.844 3.167,2.135 false 0.083,0.073 3.573,0.302 3.49,0.229 10 false HEATED OXYGEN SENSOR CIRCUIT MALFUNCTION 0.208,0.865 2.188,1.177 1.979,0.313 10 false Active Air-fuel Ratio Control 0.208,2.021 2.26,2.292 2.052,0.271 10 false Heated Oxygen Sensor Voltage 2.448,0.875 2.698,1.073 0.25,0.198 10 false Off 2.594,1.25 3.083,1.448 0.49,0.198 10 false Normal 2.188,1.656 2.688,1.854 0.5,0.198 10 false 0.59 V 2.188,2.406 2.698,2.604 0.51,0.198 10 false 0.21 V 2.521,2.052 3.219,2.25 0.698,0.198 10 false Abnormal 4.625,0.115 5.906,0.354 1.281,0.24 10 false 15 to 20 seconds 4.219,0.781 5.125,1.094 0.906,0.313 10 false Operating 0.083,0.51 2.521,0.729 2.438,0.219 10 false (P0136: ABNORMAL VOLTAGE)


Open or Short in Heated Oxygen Sensor Circuit (DTC P0137 or P0138)

During active air-fuel ratio control, the ECM calculates the Oxygen Storage Capacity (OSC)* of the Three-way Catalytic Converter (TWC) by forcibly regulating the air-fuel ratio to become rich or lean. If the heated oxygen sensor has an open or short, or the voltage output of the sensor decreases significantly, the Oxygen Storage Capacity (OSC) is indicated as having an extraordinarily high value. Even if the ECM attempts to continue regulating the air-fuel ratio to become rich or lean, the heated oxygen sensor output does not change.

While performing active air-fuel ratio control, when the target air-fuel ratio is rich and the heated oxygen sensor voltage output is 0.21 V or less (lean), the ECM interprets this as an abnormally low sensor output voltage and stores DTC P0137. When the target air-fuel ratio is lean and the voltage output is 0.59 V or more (rich) during active air-fuel ratio control, the ECM determines that the sensor voltage output is abnormally high and stores DTC P0138.

*: The Three-way Catalytic Converter (TWC) has the capability to store oxygen. The Oxygen Storage Capacity (OSC) and the emissions purification capacity of the Three-way Catalytic Converter (TWC) are mutually related. The ECM determines whether the catalyst has deteriorated based on the calculated Oxygen Storage Capacity (OSC) value (See page Engine / Hybrid System>2TR-FE ENGINE CONTROL>SFI SYSTEM(w/ Secondary Air Injection System)>P0420).

A115541
4.615,2.042 4.333,1.896 false 6.021,6.24 6.208,6.021 false 5.99,2.708 6.177,2.375 false 6.031,3.51 6.219,3.719 false 5.198,2.406 5.271,1.885 false 0.063,0.063 3.573,0.292 3.51,0.229 10 false HEATED OXYGEN SENSOR CIRCUIT LOW VOLTAGE 0.094,0.479 1.063,0.677 0.969,0.198 10 false (P0137: OPEN) 1.094,1.583 2.885,1.781 1.792,0.198 10 false Active Air-fuel Ratio Control 1,3 3.031,3.198 2.031,0.198 10 false Heated Oxygen Sensor Voltage 1.125,2.063 2.406,2.26 1.281,0.198 10 false Target Air-fuel Ratio 1.094,5.125 2.885,5.333 1.792,0.208 10 false Active Air-fuel Ratio Control 0.99,6.583 2.958,6.781 1.969,0.198 10 false Heated Oxygen Sensor Voltage 1.083,5.719 2.354,5.917 1.271,0.198 10 false Target Air-fuel Ratio 2.531,2.042 3.438,2.396 0.906,0.354 10 false Stoichiometric Air-fuel Ratio 3.24,1.708 3.5,1.906 0.26,0.198 10 false Off 3,3.24 3.458,3.438 0.458,0.198 10 false 0.21 V 0.083,4.083 3.625,4.292 3.542,0.208 10 false HEATED OXYGEN SENSOR CIRCUIT HIGH VOLTAGE 0.104,4.563 1.156,4.771 1.052,0.208 10 false (P0138: SHORT) 2.51,5.677 3.417,6.042 0.906,0.365 10 false Stoichiometric Air-fuel Ratio 3.229,5.229 3.49,5.427 0.26,0.198 10 false Off 3,6.417 3.542,6.615 0.542,0.198 10 false 0.59 V 4.646,0.646 5.948,0.865 1.302,0.219 10 false 15 to 20 seconds 4.5,1.667 5.271,1.896 0.771,0.229 10 false Operating 4.531,4.76 5.292,4.958 0.76,0.198 10 false Operating 4.531,5.323 4.927,5.521 0.396,0.198 10 false Lean 3.885,1.833 4.448,2.031 0.563,0.198 10 false Normal 6.26,5.927 7,6.125 0.74,0.198 10 false Abnormal 5.271,1.688 6.01,1.885 0.74,0.198 10 false Abnormal 6.25,3.677 6.99,3.875 0.74,0.198 10 false Abnormal 6.208,2.281 6.771,2.479 0.563,0.198 10 false Normal 4.781,2.438 5.188,2.667 0.406,0.229 10 false Rich


MONITOR STRATEGY

Required Sensors/Components (Main) Heated oxygen sensor
Required Sensors/Components (Related) Crankshaft position sensor, engine coolant temperature sensor, mass air flow meter sub-assembly, throttle position sensor and air fuel ratio sensor
Frequency of Operation Once per driving cycle: Active air-fuel ratio control detection
Continuous: Other

TYPICAL ENABLING CONDITIONS

Heated Oxygen Sensor Output Voltage (Abnormal Voltage Output, High Voltage and Low Voltage)
Active air-fuel ratio control Executing
Active air-fuel ratio control begins when all of following conditions met: -
Battery voltage 11 V or higher
Engine coolant temperature 75°C (167°F) or higher
Idling OFF
Engine speed Less than 4000 rpm
Air fuel ratio sensor status Activated
Fuel system status Closed loop
Engine load 10 to 80%

TYPICAL MALFUNCTION THRESHOLDS

Heated Oxygen Sensor Output Voltage (Abnormal Voltage Output)
Either of following conditions met: 1 or 2
1. Both of following conditions met (a) and (b)
(a) Commanded air-fuel ratio 14.3 or less
(b) Rear heated oxygen sensor voltage 0.21 to 0.59 V
2. Both of following conditions met (c) and (d)
(c) Commanded air-fuel ratio 14.9 or more
(d) Rear heated oxygen sensor voltage 0.21 to 0.59 V

Heated Oxygen Sensor Output Voltage (Low)
Both of following conditions met (a) and (b)
(a) Commanded air-fuel ratio 14.3 or less
(b) Rear heated oxygen sensor voltage Below 0.21 V

Heated Oxygen Sensor Output Voltage (High)
Both of following conditions met (a) and (b)
(a) Commanded air-fuel ratio 14.9 or more
(b) Rear heated oxygen sensor voltage Higher than 0.59 V

CONFIRMATION DRIVING PATTERN

A301803
0.49,0.49 1.688,0.74 1.198,0.25 10 false 120 km/h (75 mph) 0.552,1.365 1.75,1.615 1.198,0.25 10 false 90 km/h (56 mph) 4.01,0.708 4.25,0.958 0.24,0.25 10 false [C] 5,3.313 5.24,3.563 0.24,0.25 10 false [D] 2.625,2.104 2.865,2.354 0.24,0.25 10 false [B] 2.021,2.427 2.26,2.677 0.24,0.25 10 false [A] 1.25,2.219 1.833,2.458 0.583,0.24 10 false Idling 0.521,2.469 1.719,2.719 1.198,0.25 10 false Ignition Switch ON 2.333,3 3.198,3.25 0.865,0.25 10 false Warming up 3.51,3.021 4.885,3.292 1.375,0.271 10 false 10 minutes or more

1.

Connect the intelligent tester to the DLC3.

2.

Turn the ignition switch to ON and turn the intelligent tester on.

3.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC operation).

4.

Turn the ignition switch off and wait for at least 30 seconds.

5.

Turn the ignition switch to ON and turn the intelligent tester on [A].

6.

Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher [B].

7.

With the transmission in 5th gear or higher, drive the vehicle at 90 to 120 km/h (56 to 75 mph) for 10 minutes or more [C].

CAUTION:

When performing the confirmation driving pattern, obey all speed limits and traffic laws.


8.

Enter the following menus: Powertrain / Engine and ECT / DTC [D].

9.

Read the pending DTCs.

HINT:
·

If a pending DTC is output, the system is malfunctioning.

·

If a pending DTC is not output, perform the following procedure.



10.

Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

11.

Input the DTC: P0136, P0137 or P0138.

12.

Check the DTC judgment result.

Intelligent tester Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit



HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, shift the transmission to 2nd gear, and then perform steps [C] and [D] again.




WIRING DIAGRAM

A247766
5.74,0.458 6.24,0.677 0.5,0.219 10 false HT1B 4.188,0.438 4.698,0.656 0.51,0.219 10 false HT1B 5.5,0.385 5.615,0.542 0.115,0.156 10 false 2 5.406,0.552 5.792,0.781 0.385,0.229 10 false C75 5.406,1.333 5.688,1.479 0.281,0.146 10 false C75 5.406,2.01 5.781,2.188 0.375,0.177 10 false C75 5.74,1.24 6.24,1.469 0.5,0.229 10 false OX1B 4.177,1.198 4.656,1.396 0.479,0.198 10 false OX1B 5.458,1.167 5.771,1.396 0.313,0.229 10 false 25 5.458,1.844 5.781,2.125 0.323,0.281 10 false 28 5.74,1.917 6.042,2.167 0.302,0.25 10 false E2 3.781,1.198 4.063,1.375 0.281,0.177 10 false E2 5.74,3.104 6.333,3.344 0.594,0.24 10 false MREL 5.5,2.938 5.615,3.094 0.115,0.156 10 false 8 5.406,3.104 5.792,3.292 0.385,0.188 10 false G89 4.969,2.385 5.698,2.635 0.729,0.25 10 false Shielded 3.406,1.667 5.01,1.958 1.604,0.292 10 false Heated Oxygen Sensor 3.406,1.542 3.708,1.688 0.302,0.146 10 false C88 3.792,0.438 4.094,0.635 0.302,0.198 10 false +B 6.198,3.854 6.625,4.094 0.427,0.24 10 false ECM 4.635,0.458 4.76,0.625 0.125,0.167 10 false 1 3.625,0.458 3.75,0.625 0.125,0.167 10 false 2 4.635,1.25 4.76,1.417 0.125,0.167 10 false 3 3.625,1.25 3.75,1.417 0.125,0.167 10 false 4 2.281,0.979 2.573,1.198 0.292,0.219 10 false 1J 2.323,0.813 2.438,0.969 0.115,0.156 10 false 2 2.281,0.552 2.573,0.75 0.292,0.198 10 false 1J 2.323,0.385 2.438,0.542 0.115,0.156 10 false 5 2.281,1.427 2.552,1.625 0.271,0.198 10 false 1J 2.323,1.26 2.438,1.417 0.115,0.156 10 false 3 0.552,1.604 0.833,1.792 0.281,0.188 10 false 1H 0.823,1.583 1.021,1.802 0.198,0.219 10 false 1 0.875,0.677 1.229,0.896 0.354,0.219 10 false EFI 1.469,1.292 1.885,1.49 0.417,0.198 10 false MAIN 0.729,2.5 1.646,2.76 0.917,0.26 10 false BATT P/I 0.927,3.771 1.583,4.042 0.656,0.271 10 false Battery 1.021,1.792 2.615,2.094 1.594,0.302 10 false No. 1 Integration Relay

CAUTION / NOTICE / HINT

HINT:

Malfunctioning areas can be identified by performing the Control the Injection Volume for A/F Sensor function provided in the Active Test. The Control the Injection Volume for A/F Sensor function can help to determine whether the air fuel ratio sensor, heated oxygen sensor and other potential trouble areas are malfunctioning.

The following instructions describe how to conduct the Control the Injection Volume for A/F Sensor operation using the intelligent tester.

1.

Connect the intelligent tester to the DLC3.

2.

Start the engine and turn the intelligent tester on.

3.

Warm up the engine and run the engine at an engine speed of 2500 rpm for approximately 90 seconds.

4.

Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor.

5.

Perform the Active Test operation with the engine idling.

6.

Monitor the output voltages of the air fuel ratio and heated oxygen sensors (AFS Voltage B1S1 and O2S B1S2) displayed on the intelligent tester.



HINT:
·

Change the fuel injection volume within the range of -12.5% to +12.5%.

·

The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.



Intelligent tester Display (Sensor) Injection Volume Status Voltage
AFS Voltage B1S1
(A/F)
+12.5% Rich Below 3.1 V
AFS Voltage B1S1
(A/F)
-12.5% Lean Higher than 3.4 V
O2S B1S2
(HO2)
+12.5% Rich Higher than 0.55 V
O2S B1S2
(HO2)
-12.5% Lean Below 0.4 V

NOTICE:

The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.


A301859
0.135,0.688 0.75,0.885 0.615,0.198 10 false Case 0.844,0.635 2.906,1.021 2.063,0.385 10 false Air Fuel Ratio Sensor (Sensor 1) Output Voltage 3.427,0.625 5.573,1 2.146,0.375 10 false Heated Oxygen Sensor (Sensor 2) Output Voltage 5.948,0.635 7.052,1.01 1.104,0.375 10 false Main Suspected Trouble Area 6.427,2.208 6.719,2.479 0.292,0.271 10 false - 0.24,2.198 0.448,2.458 0.208,0.26 10 false 1 0.26,4.292 0.469,4.552 0.208,0.26 10 false 2 0.26,6.344 0.469,6.604 0.208,0.26 10 false 3 0.26,8.396 0.469,8.656 0.208,0.26 10 false 4 1.385,1.594 2,1.792 0.615,0.198 8 false +12.5% 1.417,1.823 2.031,2.021 0.615,0.198 8 false -12.5% 0.583,2.281 1.573,2.5 0.99,0.219 9 false Output Voltage 0.594,1.333 1.75,1.667 1.156,0.333 9 false Injection Volume 0.865,2.646 2.042,2.917 1.177,0.271 8 false Higher than 3.4 V 1.115,2.865 1.906,3.104 0.792,0.24 8 false Below 3.1 V 2.521,2.76 2.823,3.01 0.302,0.25 8 false OK 1.417,3.885 2.031,4.083 0.615,0.198 8 false -12.5% 1.396,3.656 2.01,3.854 0.615,0.198 8 false +12.5% 0.583,3.417 1.75,3.667 1.167,0.25 9 false Injection Volume 0.583,4.333 1.854,4.594 1.271,0.26 9 false Output Voltage 0.875,4.802 1.875,5.01 1,0.208 8 false Almost no reaction 2.552,4.719 2.938,5 0.385,0.281 8 false NG 1.427,5.938 2.042,6.135 0.615,0.198 8 false -12.5% 1.406,5.729 2.021,5.927 0.615,0.198 8 false +12.5% 0.583,5.469 1.677,5.667 1.094,0.198 9 false Injection Volume 0.583,6.417 1.635,6.656 1.052,0.24 9 false Output Voltage 0.865,6.76 1.917,6.917 1.052,0.156 8 false Higher than 3.4 V 1.115,6.979 1.906,7.219 0.792,0.24 8 false Below 3.1 V 2.531,6.865 2.833,7.115 0.302,0.25 8 false OK 0.583,7.5 1.583,7.708 1,0.208 9 false Injection Volume 1.427,8.01 2.042,8.208 0.615,0.198 8 false -12.5% 1.396,7.802 2.01,8 0.615,0.198 8 false +12.5% 0.583,8.438 1.635,8.667 1.052,0.229 9 false Output Voltage 0.865,8.927 1.823,9.125 0.958,0.198 8 false Almost no reaction 2.563,8.854 2.948,9.135 0.385,0.281 8 false NG 3.25,1.333 4.427,1.635 1.177,0.302 9 false Injection Volume 4.021,1.594 4.635,1.792 0.615,0.198 8 false +12.5% 4.042,1.813 4.656,2.01 0.615,0.198 8 false -12.5% 3.25,2.271 4.281,2.5 1.031,0.229 9 false Output Voltage 3.49,2.604 4.667,2.813 1.177,0.208 8 false Higher than 0.55 V 3.813,2.844 4.604,3.083 0.792,0.24 8 false Below 0.4 V 5.198,2.708 5.5,2.958 0.302,0.25 8 false OK 3.25,3.417 4.427,3.604 1.177,0.188 9 false Injection Volume 4.042,3.875 4.656,4.073 0.615,0.198 8 false -12.5% 4.01,3.667 4.625,3.865 0.615,0.198 8 false +12.5% 3.25,4.333 4.396,4.583 1.146,0.25 9 false Output Voltage 3.448,4.698 4.521,4.917 1.073,0.219 8 false Higher than 0.55 V 3.76,4.927 4.594,5.167 0.833,0.24 8 false Below 0.4 V 5.208,4.813 5.51,5.063 0.302,0.25 8 false OK 6.083,3.615 6.906,4.01 0.823,0.396 8 false Air fuel ratio sensor 6.094,4 6.854,4.573 0.76,0.573 8 false Air fuel ratio sensor heater 6.083,4.563 6.844,5.146 0.76,0.583 8 false Air fuel ratio sensor circuit 5.917,3.604 6.083,3.792 0.167,0.188 10 false - 5.917,3.99 6.083,4.177 0.167,0.188 10 false - 5.917,4.542 6.083,4.729 0.167,0.188 10 false - 4.042,5.948 4.656,6.146 0.615,0.198 8 false -12.5% 4.021,5.75 4.635,5.948 0.615,0.198 8 false +12.5% 3.25,5.469 4.354,5.729 1.104,0.26 9 false Injection Volume 3.25,6.417 4.198,6.667 0.948,0.25 9 false Output Voltage 3.5,6.865 4.552,7.052 1.052,0.188 8 false Almost no reaction 5.177,6.781 5.563,7.063 0.385,0.281 8 false NG 3.25,7.5 4.417,7.698 1.167,0.198 9 false Injection Volume 4.031,8 4.646,8.198 0.615,0.198 8 false -12.5% 4.01,7.813 4.625,8.01 0.615,0.198 8 false +12.5% 3.479,8.938 4.521,9.104 1.042,0.167 8 false Almost no reaction 5.156,8.854 5.542,9.135 0.385,0.281 8 false NG 3.26,8.417 4.333,8.667 1.073,0.25 9 false Output Voltage 6.083,5.438 6.927,5.75 0.844,0.313 8 false Heated oxygen sensor 6.073,5.958 6.896,6.333 0.823,0.375 8 false Heated oxygen sensor heater 6.073,6.646 6.917,7.25 0.844,0.604 8 false Heated oxygen sensor circuit 5.917,5.948 6.083,6.135 0.167,0.188 10 false - 5.917,5.417 6.083,5.604 0.167,0.188 10 false - 5.917,6.615 6.083,6.802 0.167,0.188 10 false - 6.083,7.531 6.948,7.906 0.865,0.375 8 false Fuel injector assembly 6.083,7.917 6.833,8.167 0.75,0.25 8 false Fuel pressure 6.094,8.177 6.917,9.281 0.823,1.104 8 false Gas leak from exhaust system (air-fuel ratio extremely rich or lean) 5.917,7.521 6.083,7.708 0.167,0.188 10 false - 5.917,7.906 6.083,8.094 0.167,0.188 10 false - 5.917,8.156 6.083,8.344 0.167,0.188 10 false -

HINT:
·

Following the Control the Injection Volume for A/F Sensor procedure enables technicians to check and graph the voltage outputs of both the air fuel ratio and heated oxygen sensors.

·

To display the graph, enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / All Data / AFS Voltage B1S1 and O2S B1S2.

·

Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.

·

If the OX1B wire from the ECM connector is short-circuited to the +B wire, DTC P0136 will be stored.

·

Sensor 1 refers to the sensor closest to the engine assembly.

·

Sensor 2 refers to the sensor farthest away from the engine assembly.



PROCEDURE

1.READ OUTPUT DTC
a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the intelligent tester on.


d.

Enter the following menus: Powertrain / Engine and ECT / DTC.

Powertrain > Engine > Trouble Codes
50001 61

e.

Read DTCs.

Result:
Result Proceed to
P0138 is output A
P0137 is output B
P0136 is output C
P0136, P0137 or P0138 and other DTCs are output D




A

2.READ VALUE USING INTELLIGENT TESTER (OUTPUT VOLTAGE OF HEATED OXYGEN SENSOR)

B

12.CHECK FOR EXHAUST GAS LEAK

C

10.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE INJECTION VOLUME FOR A/F SENSOR)

D

2.READ VALUE USING INTELLIGENT TESTER (OUTPUT VOLTAGE OF HEATED OXYGEN SENSOR)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the intelligent tester on.


d.

Enter the following menus: Powertrain / Engine and ECT / Data List / All Data / O2S B1S2.

Powertrain > Engine > Data List
Tester Display
O2S B1S2
50003 61 324

e.

Allow the engine to idle.


f.

Read the heated oxygen sensor output voltage while idling.

Result:
Heated Oxygen Sensor Output Voltage Proceed to
1.0 V or higher A
Below 1.0 V B




A

3.INSPECT HEATED OXYGEN SENSOR (CHECK FOR SHORT)

B

5.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (INJECTION VOLUME)
3.INSPECT HEATED OXYGEN SENSOR (CHECK FOR SHORT)
a.
A117841
1.156,1.229 1.396,1.49 true 1.167,2.146 1.396,1.865 true 2.281,2.156 2.021,1.906 true 2.281,1.208 2.01,1.5 true 0.125,0.083 0.438,0.24 0.313,0.156 10 false *a 0.938,1.135 1.365,1.375 0.427,0.24 10 false +B 0.958,2.073 1.385,2.313 0.427,0.24 10 false E2 2.333,2.073 2.76,2.313 0.427,0.24 10 false OX1B 2.333,1.125 2.76,1.365 0.427,0.24 10 false HT1B
*a Component without harness connected
(Heated Oxygen Sensor for Bank 1)


Disconnect the heated oxygen sensor connector.


b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
2 (+B) - 3 (OX1B) Always 10 kΩ or higher
2 (+B) - 4 (E2) Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT)

NG

4.CHECK HARNESS AND CONNECTOR (CHECK FOR SHORT)
a.

Turn the ignition switch off and wait for 5 minutes.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C75-2 (HT1B) - C75-25 (OX1B) Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (INJECTION VOLUME)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the intelligent tester on.


c.

Start the engine.


d.

Warm up the engine.


e.

Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor.

Powertrain > Engine > Active Test
Tester Display
Control the Injection Volume for A/F Sensor
50004 61 2

f.

Change the fuel injection volume using the intelligent tester and monitor the voltage output of the air fuel ratio and heated oxygen sensors displayed on the intelligent tester.


HINT:
·

Change the fuel injection volume within the range of -12.5% to +12.5%.

·

The air fuel ratio sensor is displayed as AFS Voltage B1S1, and the heated oxygen sensor is displayed as O2S B1S2 on the intelligent tester.

·

If the sensor output voltage does not change (almost no reaction) while performing the Active Test, the sensor may be malfunctioning.

·

The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.

Result:
Intelligent tester Display (Sensor) Voltage Variation Proceed to
AFS Voltage B1S1 Alternates between higher than and below 3.3 V OK
Remains higher than 3.3 V NG
Remains below 3.3 V




HINT:

A normal heated oxygen sensor voltage (O2S B1S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor voltage remains either below or higher than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.


A121606
5.885,2.458 6.365,1.396 false 5.542,2.271 6.365,1.396 false 5.708,1.667 6.365,1.396 false 5.563,2.448 5.844,2.667 false 3.021,1.26 2.865,1.677 false 4.292,1.771 4.094,1.698 false 3.573,2.625 3.188,2.938 false 1.958,1.99 2.125,1.99 false 1.958,2.948 2.156,2.948 false 1.531,1.896 1.906,2.052 0.375,0.156 10 3.3 V 2.656,0.292 3.208,0.521 0.552,0.229 10 +12.5% 4.031,1.135 4.573,1.417 0.542,0.281 10 -12.5% 1.656,2.854 1.906,3.052 0.25,0.198 10 1 V 1.667,3.385 1.906,3.583 0.24,0.198 10 0 V 3.073,1.146 3.833,1.344 0.76,0.198 10 Malfunction 5.854,2.615 6.646,2.885 0.792,0.271 10 Malfunction 4.76,0.125 5.865,0.354 1.104,0.229 10 Injection Volume 3.635,2.51 5.563,2.729 1.927,0.219 10 Heated Oxygen Sensor Output 6.406,1.125 6.958,1.813 0.552,0.688 10 Air Fuel Ratio Sensor Output 4.344,1.729 4.865,1.958 0.521,0.229 10 Normal


OK

6.INSPECT AIR FUEL RATIO SENSOR

NG

7.REPLACE AIR FUEL RATIO SENSOR
6.INSPECT AIR FUEL RATIO SENSOR
HINT:

This air fuel ratio sensor test is to check the air fuel ratio sensor current during the fuel-cut. When the sensor is normal, the sensor current will be below 3.6 mA in this test.



b.

Drive the vehicle according to the driving pattern listed below.

i.

Warm up the engine.


ii.

Drive the vehicle at 60 km/h (40 mph) or more for 10 minutes or more.


iii.

Stop the vehicle.


iv.

Accelerate the vehicle to 60 km/h (40 mph) or more and decelerate for 5 seconds or more. Perform this 3 times.

A152792
1.24,2.51 2.635,2.719 1.396,0.208 10 10 minutes or more 2.865,2.51 4.344,2.719 1.479,0.208 10 5 seconds or more 4.24,2.51 5.583,2.74 1.344,0.229 10 5 seconds or more 5.625,2.51 6.99,2.729 1.365,0.219 10 5 seconds or more 0.156,0.083 1.781,0.385 1.625,0.302 12 Driving Pattern: 0.302,1.229 1.01,1.635 0.708,0.406 10 60 km/h (40 mph) 0.344,2.052 0.979,2.469 0.635,0.417 10 0 km/h (0 mph)



c.

Enter the following menus: Powertrain / Engine and ECT / Data List / AFS Current B1S1.

Powertrain > Engine > Data List
Tester Display
AFS Current B1S1
50003 61 473

d.

Read the value of the air fuel ratio sensor current while the fuel-cut operation is being performed.

Standard current:

Below 3.6 mA


HINT:
·

To measure the air fuel ratio sensor current precisely, perform the fuel-cut operation as long as possible.

·

If it is difficult to measure the air fuel ratio sensor current, use the snapshot function of the intelligent tester.




Result:
Proceed to
OK
NG



OK

15.REPLACE HEATED OXYGEN SENSOR

NG

7.REPLACE AIR FUEL RATIO SENSOR
7.REPLACE AIR FUEL RATIO SENSOR

Result:
Proceed to
NEXT



NEXT

8.PERFORM CONFIRMATION DRIVING PATTERN
8.PERFORM CONFIRMATION DRIVING PATTERN
a.

Perform Confirmation Driving Pattern (P0136, P0137 and P0138).


Result:
Proceed to
NEXT



NEXT

9.CHECK WHETHER DTC OUTPUT RECURS (DTC P0136, P0137 OR P0138 IS OUTPUT AGAIN)
9.CHECK WHETHER DTC OUTPUT RECURS (DTC P0136, P0137 OR P0138 IS OUTPUT AGAIN)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the intelligent tester on.


c.

Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

Powertrain > Engine > Utility
Tester Display
All Readiness
50005 61 20

d.

Input DTCs: P0136, P0137 or P0138.


e.

Check that the DTC monitor is NORMAL. If the DTC monitor is INCOMPLETE, perform the driving pattern again but increase the vehicle speed.

Result:
Display (DTC Output) Proceed to
ABNORMAL
(P0136, P0137 or P0138 output)
A
NORMAL
(No DTC output)
B




A

B

END

10.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE INJECTION VOLUME FOR A/F SENSOR)
a.

Connect the intelligent tester to the DLC3.


b.

Start the engine.


c.

Turn the intelligent tester on.


d.

Warm up the engine.


e.

Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / All Data / O2S B1S2.

Powertrain > Engine > Active Test
Active Test Display
Control the Injection Volume for A/F Sensor
Data List Display
O2S B1S2
50004 61 2 324

f.

Change the fuel injection volume using the intelligent tester and monitor the voltage output of the heated oxygen sensors displayed on the intelligent tester.

HINT:
·

Change the fuel injection volume within the range of -12.5% to +12.5%.

·

The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.



Standard voltage:

Fluctuates between 0.4 V or less and 0.5 V or higher.



Result:
Proceed to
OK
NG



OK

11.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE INJECTION VOLUME FOR A/F SENSOR)

NG

12.CHECK FOR EXHAUST GAS LEAK
11.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (CONTROL THE INJECTION VOLUME FOR A/F SENSOR)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the intelligent tester on.


c.

Start the engine.


d.

Warm up the engine.


e.

Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor.

Powertrain > Engine > Active Test
Tester Display
Control the Injection Volume for A/F Sensor
50004 61 2

f.

Change the fuel injection volume using the intelligent tester and monitor the voltage output of the air fuel ratio and heated oxygen sensors displayed on the intelligent tester.


HINT:
·

Change the fuel injection volume within the range of -12.5% to +12.5%.

·

The air fuel ratio sensor is displayed as AFS Voltage B1S1, and the heated oxygen sensor is displayed as O2S B1S2 on the intelligent tester.

·

If the sensor output voltage does not change (almost no reaction) while performing the Active Test, the sensor may be malfunctioning.

·

The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.

Result:
Intelligent tester Display (Sensor) Voltage Variation Proceed to
AFS Voltage B1S1 Alternates between higher than and below 3.3 V OK
Remains higher than 3.3 V NG
Remains below 3.3 V


HINT:

A normal heated oxygen sensor voltage (O2S B1S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor voltage remains either below or higher than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.


A121606
5.885,2.458 6.365,1.396 false 5.542,2.271 6.365,1.396 false 5.708,1.667 6.365,1.396 false 5.563,2.448 5.844,2.667 false 3.021,1.26 2.865,1.677 false 4.292,1.771 4.094,1.698 false 3.573,2.625 3.188,2.938 false 1.958,1.99 2.125,1.99 false 1.958,2.948 2.156,2.948 false 1.531,1.896 1.906,2.052 0.375,0.156 10 3.3 V 2.656,0.292 3.208,0.521 0.552,0.229 10 +12.5% 4.031,1.135 4.573,1.417 0.542,0.281 10 -12.5% 1.656,2.854 1.906,3.052 0.25,0.198 10 1 V 1.667,3.385 1.906,3.583 0.24,0.198 10 0 V 3.073,1.146 3.833,1.344 0.76,0.198 10 Malfunction 5.854,2.615 6.646,2.885 0.792,0.271 10 Malfunction 4.76,0.125 5.865,0.354 1.104,0.229 10 Injection Volume 3.635,2.51 5.563,2.729 1.927,0.219 10 Heated Oxygen Sensor Output 6.406,1.125 6.958,1.813 0.552,0.688 10 Air Fuel Ratio Sensor Output 4.344,1.729 4.865,1.958 0.521,0.229 10 Normal




OK

CHECK EXTREMELY RICH OR LEAN ACTUAL AIR FUEL RATIO AND REPAIR CAUSE (FUEL INJECTOR ASSEMBLY, FUEL PRESSURE, GAS LEAK FROM SYSTEM)

NG

7.REPLACE AIR FUEL RATIO SENSOR
12.CHECK FOR EXHAUST GAS LEAK
a.

Check for exhaust gas leakage.

OK:

No gas leakage.



Result:
Proceed to
OK
NG



OK

13.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)

NG

REPAIR OR REPLACE EXHAUST GAS LEAKAGE POINT

13.INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)

Result:
Proceed to
OK
NG



OK

14.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)

NG

14.CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)
a.

Disconnect the heated oxygen sensor connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
C88-1 (HT1B) - C75-2 (HT1B) Always Below 1 Ω
C88-3 (OX1B) - C75-25 (OX1B) Always Below 1 Ω
C88-4 (E2) - C75-28 (E2) Always Below 1 Ω
C88-1 (HT1B) or C75-2 (HT1B) - Body ground Always 10 kΩ or higher
C88-3 (OX1B) or C75-25 (OX1B) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

15.REPLACE HEATED OXYGEN SENSOR

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

15.REPLACE HEATED OXYGEN SENSOR

Result:
Proceed to
NEXT



NEXT

16.PERFORM CONFIRMATION DRIVING PATTERN
16.PERFORM CONFIRMATION DRIVING PATTERN
a.

Perform Confirmation Driving Pattern (P0136, P0137 and P0138).


Result:
Proceed to
NEXT



NEXT

17.CHECK WHETHER DTC OUTPUT RECURS (DTC P0136, P0137 OR P0138 IS OUTPUT AGAIN)
17.CHECK WHETHER DTC OUTPUT RECURS (DTC P0136, P0137 OR P0138 IS OUTPUT AGAIN)
a.

Connect the intelligent tester to the DLC3.


b.

Turn the intelligent tester on.


c.

Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

Powertrain > Engine > Utility
Tester Display
All Readiness
50005 61 20

d.

Input DTCs: P0136, P0137 and P0138.


e.

Check that the DTC monitor is NORMAL. If the DTC monitor is INCOMPLETE, perform the driving pattern again but increase the vehicle speed.

Result:
Display (DTC Output) Proceed to
ABNORMAL
(P0136, P0137 or P0138 output)
A
NORMAL
(No DTC output)
B




A

B

END