Sensor 2 refers to the sensor mounted behind the three way catalytic converter and located far from the engine assembly.
A three way catalytic converter is used in order to convert carbon monoxide, hydrocarbons and nitrogen oxide into less harmful substances. To allow the three way catalytic converter to function effectively, it is necessary to keep the air fuel ratio of the engine near the stoichiometric air fuel ratio. For the purpose of helping the ECM to deliver accurate air fuel ratio control, a heated oxygen sensor is used.
The heated oxygen sensor is located behind the three way catalytic converter and detects the oxygen concentration in the exhaust gas. Since the sensor is integrated with a heater that heats the sensing portion, it is possible to detect the oxygen concentration even when the intake air volume is low (the exhaust gas temperature is low).
When the air fuel ratio becomes lean, the oxygen concentration in the exhaust gas is rich. The heated oxygen sensor informs the ECM that the post three way catalytic converter air fuel ratio is lean (low voltage, i.e. below 0.45 V).
Conversely, when the air fuel ratio is richer than the stoichiometric air fuel level, the oxygen concentration in the exhaust gas becomes lean. The heated oxygen sensor informs the ECM that the post three way catalytic converter air fuel ratio is rich (high voltage, i.e. higher than 0.45 V). The heated oxygen sensor has the property of changing its output voltage drastically when the air fuel ratio is close to the stoichiometric level.
The ECM uses the supplementary information from the heated oxygen sensor to determine whether the air fuel ratio after the three way catalytic converter is rich or lean, and adjusts the fuel injection time accordingly. Thus, if the heated oxygen sensor is working improperly due to internal malfunctions, the ECM is unable to compensate for deviations in primary air fuel ratio control.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Memory |
|---|---|---|---|---|---|
| P0136 | Oxygen Sensor Circuit Malfunction (Bank 1 Sensor 2) | ·
Abnormal voltage output: During active air fuel ratio control, conditions (a) and (b) are met for a certain period of time (2 trip detection logic): 1.
The heated oxygen sensor voltage does not decrease to below 0.21 V. 2.
The heated oxygen sensor voltage does not increase to higher than 0.59 V. |
·
Open or short in heated oxygen sensor circuit ·
Heated oxygen sensor ·
Air fuel ratio sensor ·
Gas leak from exhaust system |
Comes on | DTC stored |
| P0137 | Oxygen Sensor Circuit Low Voltage (Bank 1 Sensor 2) | ·
Low voltage (open): During active air fuel ratio control, conditions (a) and (b) are met for a certain period of time (2 trip detection logic): 1.
The heated oxygen sensor voltage output is below 0.21 V. 2.
The target air fuel ratio is rich. |
·
Open in heated oxygen sensor circuit ·
Heated oxygen sensor ·
Air fuel ratio sensor ·
Gas leak from exhaust system |
Comes on | DTC stored |
| P0138 | Oxygen Sensor Circuit High Voltage (Bank 1 Sensor 2) | ·
High voltage (short): During active air fuel ratio control, conditions (a) and (b) are met for a certain period of time (2 trip detection logic): 1.
The heated oxygen sensor voltage output is 0.59 V or higher. 2.
The target air fuel ratio is lean. |
·
Short in heated oxygen sensor circuit ·
Heated oxygen sensor ·
Air fuel ratio sensor ·
ECM |
Comes on | DTC stored |
Refer to DTC P2195 (See page Engine / Hybrid System>2TR-FBE ENGINE CONTROL>SFI SYSTEM>P2195).
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON and turn the intelligent tester on.
Clear the DTCs (even if no DTCs are stored, perform the clear DTC operation).
Turn the ignition switch off and wait for at least 30 seconds.
Turn the ignition switch to ON and turn the intelligent tester on [A].
Start the engine and warm it up until the engine coolant temperature reaches 75°C (167°F) or higher [B].
With the transmission in 5th gear or higher, drive the vehicle at 90 to 120 km/h (56 to 75 mph) for 10 minutes or more [C].
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
Enter the following menus: Powertrain / Engine and ECT / DTC [D].
Read the pending DTCs.
If a pending DTC is output, the system is malfunctioning.
If a pending DTC is not output, perform the following procedure.
Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
Input the DTC: P0136, P0137 or P0138.
Check the DTC judgment result.
| Intelligent tester Display | Description |
|---|---|
| NORMAL | ·
DTC judgment completed ·
System normal |
| ABNORMAL | ·
DTC judgment completed ·
System abnormal |
| INCOMPLETE | ·
DTC judgment not completed ·
Perform driving pattern after confirming DTC enabling conditions |
| N/A | ·
Unable to perform DTC judgment ·
Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit |
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE or N/A, shift the transmission to 2nd gear, and then perform steps [C] and [D] again.
This confirmation driving pattern is used in the "Perform Confirmation Driving Pattern" procedure of the following diagnostic troubleshooting procedure.
Intelligent tester only:
Malfunctioning areas can be identified by performing the Control the Injection Volume for A/F sensor function provided in the Active Test. The Control the Injection Volume for A/F sensor function can help to determine whether the air fuel ratio sensor, heated oxygen sensor and other potential trouble areas are malfunctioning.
The following instructions describe how to conduct the Control the Injection Volume for A/F sensor operation using the intelligent tester.
Connect the intelligent tester to the DLC3.
Start the engine and turn the tester on.
Warm up the engine at an engine speed of 2500 rpm for approximately 90 seconds.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F sensor.
Perform the Active Test operation with the engine idling (press the RIGHT or LEFT button to change the fuel injection volume).
Monitor the output voltages of the air fuel ratio sensor and heated oxygen sensor (AFS Voltage B1S1 and O2S B1S2) displayed on the tester.
The Control the Injection Volume for A/F sensor operation lowers the fuel injection volume by 12.5% or increases the injection volume by 12.5%.
Each sensor reacts in accordance with increases and decreases in the fuel injection volume.
| Tester Display (Sensor) | Injection Volume | Status | Voltage |
|---|---|---|---|
| AFS Voltage B1S1
(Air fuel ratio sensor) |
+12.5% | Rich | Below 3.1 V |
| AFS Voltage B1S1
(Air fuel ratio sensor) |
-12.5% | Lean | Higher than 3.4 V |
| O2S B1S2
(Heated oxygen sensor) |
+12.5% | Rich | Higher than 0.55 V |
| O2S B1S2
(Heated oxygen sensor) |
-12.5% | Lean | Below 0.4 V |
The air fuel ratio sensor has an output delay of a few seconds and the heated oxygen sensor has a maximum output delay of approximately 20 seconds.
Following the Control the Injection Volume for air fuel ratio sensor procedure enables technicians to check and graph the voltage outputs of both the air fuel ratio and heated oxygen sensor sensors.
To display the graph, enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor / A/F Control System / AFS Voltage B1S1 and O2S B1S2.
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.
Sensor 1 refers to the sensor closest to the engine assembly.
Sensor 2 refers to the sensor farthest away from the engine assembly.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / DTC.
Read DTCs.
| Result | Proceed to |
|---|---|
| DTC P0138 is output | A |
| DTC P0137 is output | B |
| DTC P0136 is output | C |
| P0136, P0137 or P0138 and other DTCs are output | D |
A
B
C
D
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Data List / A/F Control System / O2S B1S2.
| Tester Display |
|---|
| O2S B1S2 |
Allow the engine to idle.
Read the heated oxygen sensor output voltage while idling.
| Result | Proceed to |
|---|---|
| Higher than 1.0 V | A |
| Below 1.0 V | B |
A
B
Inspect the heated oxygen sensor connector
Click hereEngine / Hybrid System>2TR-FBE ENGINE CONTROL>HEATED OXYGEN SENSOR>INSPECTION
Reconnect the heated oxygen sensor connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C97-18 (HT1B) - C97-13 (OX1B) | Always | 10 kΩ or higher |
Reconnect the ECM connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the intelligent tester to the DLC3.
Start the engine.
Turn the tester on.
Warm up the engine.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor.
| Active Test Display |
|---|
| Control the Injection Volume for A/F Sensor |
| Data List Display |
|---|
| AFS Voltage B1S1 |
| O2S B1S2 |
Change the fuel injection volume using the tester and monitor the voltage output of the air fuel ratio sensor and heated oxygen sensor displayed on the tester.
Change the fuel injection volume within the range of -12.5% to +12.5%.
The air fuel ratio sensor is displayed as AFS Voltage B1S1, and the heated oxygen sensor is displayed as O2S B1S2 on the intelligent tester.
| Tester Display (Sensor) | Voltage Variation | Proceed to |
|---|---|---|
| AFS Voltage B1S1
(Air fuel ratio sensor) |
Alternates between higher than and below 3.3 V | OK |
| AFS Voltage B1S1
(Air fuel ratio sensor) |
Remains at higher than 3.3 V | NG |
| AFS Voltage B1S1
(Air fuel ratio sensor) |
Remains at below 3.3 V |
A normal heated oxygen sensor voltage (O2S B1S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor voltage remains at either below or higher than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.
OK
NG
This air fuel ratio sensor test is used to check the air fuel ratio sensor current during the fuel-cut operation. When the sensor is normal, the sensor current is below 3 mA in this test.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / DTC / Clear.
Clear DTCs.
Drive the vehicle according to the driving pattern listed below:
Warm up the engine.
Drive the vehicle at 60 km/h (37 mph) or more for 10 minutes or more.
Stop the vehicle.
Accelerate the vehicle to 60 km/h (37 mph) or more and then decelerate for 5 seconds or more. Repeat this process at least 3 times.
Enter the following menus: Powertrain / Engine and ECT / Data List / A/F Control System / AFS Current B1S1.
| Tester Display |
|---|
| AFS Current B1S1 |
Read the value of the air fuel ratio sensor current while the fuel-cut operation is being performed.
Below 3.0 mA
To measure the air fuel ratio sensor current precisely, perform the fuel-cut operation as long as possible.
If it is difficult to measure the air fuel ratio sensor current, use the snapshot function of the intelligent tester.
| Result | Proceed to |
|---|---|
| Outside standard range | B |
| Within standard range | A |
A
B
Replace the air fuel ratio sensor.
Click hereEngine / Hybrid System>2TR-FBE ENGINE CONTROL>AIR FUEL RATIO SENSOR>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Refer to Confirmation Driving Pattern.
| Proceed to |
|---|
| NEXT |
NEXT
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
| Tester Display |
|---|
| All Readiness |
Input DTCs: P0136, P0137 and P0138.
Check that DTC monitor is NORMAL. If DTC monitor is INCOMPLETE, perform the driving pattern by accelerating the vehicle to a higher speed and using the second gear to decelerate the vehicle.
| Result | Proceed to |
|---|---|
| NORMAL
(No DTC output) |
A |
| ABNORMAL
(DTC P0136, P0137 or P0138 output) |
B |
A
B
Check for exhaust gas leakage.
No gas leakage.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the heated oxygen sensor.
Click hereEngine / Hybrid System>2TR-FBE ENGINE CONTROL>HEATED OXYGEN SENSOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the heated oxygen sensor connector.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C88-1 (HT1B) - C97-18 (HT1B) | Always | Below 1 Ω |
| C88-3 (OX1B) - C97-13 (OX1B) | Always | Below 1 Ω |
| C88-4 (E2) - C97-14 (EX1B) | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C88-1 (HT1B) or C97-18 (HT1B) - Body ground | Always | Below 1 Ω |
| C88-3 (OX1B) or C97-13 (OX1B) - Body ground | Always | Below 1 Ω |
| C88-4 (E2) or C97-14 (EX1B) - Body ground | Always | Below 1 Ω |
Reconnect the heated oxygen sensor connector.
Reconnect the ECM connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Replace the heated oxygen sensor.
Click hereEngine / Hybrid System>2TR-FBE ENGINE CONTROL>HEATED OXYGEN SENSOR>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT
Refer to Confirmation Driving Pattern.
| Proceed to |
|---|
| NEXT |
NEXT
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Enter the following menus: Powertrain / Engine and ECT / Utility / All Readiness.
| Tester Display |
|---|
| All Readiness |
Input DTCs: P0136, P0137 and P0138.
Check that DTC monitor is NORMAL. If DTC monitor is INCOMPLETE, perform the driving pattern by accelerating the vehicle to a higher speed and using second gear to decelerate the vehicle.
| Result | Proceed to |
|---|---|
| NORMAL
(No DTC output) |
A |
| ABNORMAL
(DTC P0136, P0137 or P0138 output) |
B |
A
B
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the tester on.
Start the engine.
Enter the following menu items: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor.
| Active Test Display |
|---|
| Control the Injection Volume for A/F Sensor |
| Data List Display |
|---|
| AFS Voltage B1S1 |
| O2S B1S2 |
Change the fuel injection volume using the tester, and monitor the voltage output of the heated oxygen sensor displayed on the tester.
Change the fuel injection volume within the range of -12.5% and +12.5%.
The heated oxygen sensor is displayed as O2S B1S2 on the intelligent tester.
| Tester Display (Sensor) | Voltage Variation | Proceed to |
|---|---|---|
| O2S B1S2
(Heated oxygen sensor) |
Alternates between 0.5 V or more and less than 0.4 V | OK |
| Remains at 0.5 V or more | NG | |
| Remains at less than 0.4 V |
A normal heated oxygen sensor voltage (O2S B1S2) reacts in accordance with increases and decreases in fuel injection volumes. When the heated oxygen sensor (sensor 2) voltage remains at either 0.5 V or more or less than 0.4 V despite the heated oxygen sensor indicating a normal reaction, the heated oxygen sensor (sensor 2) is malfunctioning.
OK
NG
Connect the intelligent tester to the DLC3.
Start the engine.
Turn the tester on.
Warm up the engine.
Enter the following menus: Powertrain / Engine and ECT / Active Test / Control the Injection Volume for A/F Sensor.
| Active Test Display |
|---|
| Control the Injection Volume for A/F Sensor |
| Data List Display |
|---|
| AFS Voltage B1S1 |
| O2S B1S2 |
Change the fuel injection volume using the tester and monitor the voltage output of the air fuel ratio sensor and heated oxygen sensor displayed on the tester.
Change the fuel injection volume within the range of -12.5% to +12.5%.
The air fuel ratio sensor is displayed as AFS Voltage B1S1, and the heated oxygen sensor is displayed as O2S B1S2 on the intelligent tester.
| Tester Display (Sensor) | Voltage Variation | Proceed to |
|---|---|---|
| AFS Voltage B1S1
(Air fuel ratio sensor) |
Alternates between higher than and below 3.3 V | OK |
| AFS Voltage B1S1
(Air fuel ratio sensor) |
Remains at higher than 3.3 V | NG |
| AFS Voltage B1S1
(Air fuel ratio sensor) |
Remains at below 3.3 V |
A normal heated oxygen sensor voltage (O2S B1S2) reacts in accordance with increases and decreases in fuel injection volumes. When the air fuel ratio sensor voltage remains at either below or higher than 3.3 V despite the heated oxygen sensor indicating a normal reaction, the air fuel ratio sensor is malfunctioning.
OK
NG