Home › Engine / Hybrid System › 1GD-FTV (ENGINE CONTROL) › ECD SYSTEM (w/ Urea SCR System) › 2018.06–2020.08
RM27T0E _51 Engine / Hybrid System _053660 1GD-FTV ENGINE CONTROL _0260461 ECD SYSTEM(w/ Urea SCR System) C

1GD-FTV ENGINE CONTROL  ECD SYSTEM(w/ Urea SCR System)  U02A3  Lost Communication with PM Sensor  


DESCRIPTION

The ECM sends and receives data to and from the Particulate matter sensor via local CAN communication.

U02A3
DTC Detection Drive Pattern DTC Detection Condition Trouble Area
Turn the engine switch on (IG) and wait for 1.6 seconds or more. Communication stops between the ECM and the Particulate matter sensor for 1.6 seconds or more.
(1 trip detection logic)
·

Particulate Matter Sensor

·

Harness or connector

·

ECM



MONITOR DESCRIPTION

The ECM stores a DTC when a communication malfunction occurs between the Particulate matter sensor and ECM.

CAUTION / NOTICE / HINT

NOTICE:

Inspect the fuses of circuits related to this system before performing the following inspection procedure.


HINT:

Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.


PROCEDURE

1.CHECK PARTICULATE MATTER SENSOR (BATT TERMINAL)
a.

Disconnect the Particulate matter sensor connector.


b.

Turn the engine switch on (IG).


c.
A426728C02
1.573,0.167 2,0.438 0.427,0.271 0.896,1.698 1.385,1.271 true 2.552,1.688 2.177,1.292 true 1.719,0.219 2.031,0.417 0.313,0.198 10 false s8 0.5,1.698 1.115,1.896 0.615,0.198 10 false BATT 2.552,1.74 3.167,1.938 0.615,0.198 10 false GND 0.125,0.104 0.74,0.302 0.615,0.198 10 false *a
*a Front view of wire harness connector
(to Particulate matter sensor)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
s8-1 (BATT) - s8-4 (GND) Engine switch on (IG) 11 to 14 V




OK

2.CHECK HARNESS AND CONNECTOR (PARTICULATE MATTER SENSOR - ECM)

NG

6.INSPECT NOX PM RELAY
2.CHECK HARNESS AND CONNECTOR (PARTICULATE MATTER SENSOR - ECM)
a.

Disconnect the Particulate matter sensor connector.


b.

Disconnect the ECM connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
s8-2 (CAN+) - G184-27 (CANU) Always Below 1 Ω
s8-3 (CAN-) - G184-35 (CAND) Always Below 1 Ω
s8-2 (CAN+) or G184-27 (CANU) - Body ground and other terminals Always 10 kΩ or higher
s8-3 (CAN-) or G184-35 (CAND) - Body ground and other terminals Always 10 kΩ or higher




OK

3.REPLACE PARTICULATE MATTER SENSOR

NG

REPAIR OR REPLACE HARNESS AND CONNECTOR

3.REPLACE PARTICULATE MATTER SENSOR
a.


NEXT

4.CLEAR DTC
4.CLEAR DTC
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) and turn the GTS on.



d.

Turn the engine switch off for 30 seconds.



NEXT

5.CHECK DTC OUTPUT
5.CHECK DTC OUTPUT
a.

Connect the GTS to the DLC3.


b.

Turn the engine switch on (IG) wait for 1.6 seconds or more.


c.

Turn the GTS on.


d.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.


e.

Read the DTCs.

Result:
Result Proceed to
No DTC is output A
DTC U02A3 is output B




A

END

B

6.INSPECT NOX PM RELAY

OK

7.CHECK HARNESS AND CONNECTOR (PARTICULATE MATTER SENSOR - NOX PM RELAY - NO. 1 INTEGRATION RELAY)

NG

REPLACE NOX PM RELAY

7.CHECK HARNESS AND CONNECTOR (PARTICULATE MATTER SENSOR - NOX PM RELAY - NO. 1 INTEGRATION RELAY)
a.

Disconnect the Particulate matter sensor connector.


b.

Remove the NOx PM relay from the engine relay block.


c.

Remove the No. 1 integration relay from the engine room relay block.


d.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
s8-1 (BATT) - NOx PM relay terminal 3 Always Below 1 Ω
s8-4 (GND) - Body ground Always Below 1 Ω
NOx PM relay terminal 2 - Body ground Always Below 1 Ω
NOx PM relay terminal 1 - 1W-2 Always Below 1 Ω
NOx PM relay terminal 3 or s6-1 (BATT) - Body ground and other terminals Always 10 kΩ or higher



e.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
NOx PM relay terminal 5 - Body ground Always 11 to 14 V




OK

NG

REPAIR OR REPLACE HARNESS AND CONNECTOR