2011-2013 Land Cruiser · Service Manual Engine / Hybrid / EV System

P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2)

Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011

Also covers:

DESCRIPTION

  1. Refer to DTC P0136 (Click here).

HINT:
  1. When any of these DTCs are stored, the ECM enters fail-safe mode. The ECM turns off the Heated Oxygen (HO2) sensor heater in fail-safe mode. Fail-safe mode continues until the engine switch is turned off.

  2. The ECM provides a pulse width modulated control circuit to adjust the current through the heater. The HO2 sensor heater circuit uses a relay on the +B side of the circuit.

    A164717E03

DTC Code
DTC Detection Condition
Trouble Area
P0037
P0057
The Heated Oxygen (HO2) sensor heater current is below 0.3 A (1 trip detection logic).
  1. Open in HO2 sensor heater circuit
  2. HO2 sensor heater (for sensor 2)
  3. Integration relay (EFI)
  4. ECM
P0038
P0058
The Heated Oxygen (HO2) sensor heater current is higher than 2 A (1 trip detection logic).
  1. Short in HO2 sensor heater circuit
  2. HO2 sensor heater (for sensor 2)
  3. Integration relay (EFI)
  4. ECM

MONITOR DESCRIPTION

The sensing portion of the Heated Oxygen (HO2) sensor has a zirconia element which is used to detect the oxygen concentration in the exhaust gas. If the zirconia element is at the appropriate temperature, and the difference between the oxygen concentrations surrounding the inside and outside surfaces of the sensor is large, the zirconia element generates voltage signals. In order to increase the oxygen concentration detecting capacity of the zirconia element, the ECM supplements the heat from the exhaust with heat from a heating element inside the sensor.
  1. Heated oxygen sensor heater range check (P0037, P0038, P0057 and P0058):
    The ECM monitors the current applied to the HO2 sensor heater to check the heater for malfunctions. If the current is below the threshold value, the ECM determines that there is an open circuit in the heater. If the current is above the threshold value, the ECM determines that there is a short circuit in the heater.
    The ECM constantly monitors the current applied to the heater. If the ECM detects an open or short circuit, the ECM turns the MIL on and stores a DTC.
    If a malfunction is detected, the ECM cuts off the current applied to the heater.
    Example:
    The ECM stores DTC P0038 or P0058 when the current in the HO2 sensor heater is higher than 2 A. Conversely, when the heater current is below 0.3 A, DTC P0037 or P0057 is stored.


WIRING DIAGRAM

Refer to DTC P0136 (Click here).

CONFIRMATION DRIVING PATTERN

These DTCs are stored when the engine idles for 110 seconds or more.

INSPECTION PROCEDURE

HINT:
  1. Sensor 2 refers to the sensor mounted behind the Three-Way Catalytic Converter (TWC) and located far from the engine assembly.
  2. Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.


1. INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)
A180104E02
  1. Disconnect the Heated Oxygen (HO2) sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (HT1B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT1B) - 4 (E1)
    Always
    10 kΩ or higher
    1 (HT2B) - 2 (+B)
    20°C (68°F)
    11 to 16 Ω
    1 (HT2B) - 4 (E1)
    Always
    10 kΩ or higher



NG
REPLACE HEATED OXYGEN SENSOR (Click here)
OK


2. CHECK TERMINAL VOLTAGE (+B OF HO2 SENSOR)
A180105E02
  1. Disconnect the HO2 sensor connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    C20-2 (+B) - Body ground
    Engine switch on (IG)
    11 to 14 V
    C56-2 (+B) - Body ground
    Engine switch on (IG)
    11 to 14 V

    Result 
    Result
    Proceed to
    NG
    A
    OK
    B



B
Go to step 5
A


3. INSPECT INTEGRATION RELAY (EFI MAIN)
A148742E04
  1. Remove the integration relay from the engine room relay block.

  1. Inspect the EFI MAIN fuse.

    1. Remove the EFI MAIN fuse from the integration relay.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      EFI MAIN fuse
      Always
      Below 1 Ω

    3. Reinstall the EFI MAIN fuse.

  1. Inspect the EFI relay.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1C-1 - 1B-4
      When no battery voltage applied to terminals 1B-2 and 1B-3
      10 kΩ or higher
      When battery voltage applied to terminals 1B-2 and 1B-3
      Below 1 Ω



NG
REPLACE INTEGRATION RELAY (EFI MAIN)
OK


4. CHECK HARNESS AND CONNECTOR (HO2 SENSOR - INTEGRATION RELAY)
A181325E01
  1. Check the EFI NO. 2 fuse.

    1. Remove the EFI NO. 2 fuse from the engine room relay block.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      EFI NO. 2 fuse
      Always
      Below 1 Ω

    3. Reinstall the EFI NO. 2 fuse.

  1. Disconnect the HO2 sensor connector.

  1. Remove the integration relay from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    C20-2 (+B) - 1B-4
    Always
    Below 1 Ω
    C56-2 (+B) - 1B-4
    Always
    Below 1 Ω
    C20-2 (+B) or 1B-4 - Body ground
    Always
    10 kΩ or higher
    C56-2 (+B) or 1B-4 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CHECK ECM POWER SOURCE CIRCUIT (Click here)

5. CHECK HARNESS AND CONNECTOR (HO2 SENSOR - ECM)
A182109E01
  1. Disconnect the HO2 sensor connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (for LHD):
    Tester Connection
    Condition
    Specified Condition
    C20-1 (HT1B) - C45-45 (HT1B)
    Always
    Below 1 Ω
    C56-1 (HT2B) - C45-44 (HT2B)
    Always
    Below 1 Ω
    C20-1 (HT1B) or C45-45 (HT1B) - Body ground
    Always
    10 kΩ or higher
    C56-1 (HT2B) or C45-44 (HT2B) - Body ground
    Always
    10 kΩ or higher

    Standard Resistance (for RHD):
    Tester Connection
    Condition
    Specified Condition
    C20-1 (HT1B) - C46-45 (HT1B)
    Always
    Below 1 Ω
    C56-1 (HT2B) - C46-44 (HT2B)
    Always
    Below 1 Ω
    C20-1 (HT1B) or C46-45 (HT1B) - Body ground
    Always
    10 kΩ or higher
    C56-1 (HT2B) or C46-44 (HT2B) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6. CHECK WHETHER DTC OUTPUT RECURS
  1. Connect the intelligent tester to the DLC3.

  1. Turn the engine switch on (IG).

  1. Turn the tester on.

  1. Clear DTCs (Click here).

  1. Start the engine.

  1. Allow the engine to idle for 2 minutes or more.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Read DTCs.

    Result 
    Result
    Proceed to
    No DTC is output
    A
    P0037, P0038, P0057 and/or P0058 is output
    B



B
REPLACE ECM (Click here)
A

CHECK FOR INTERMITTENT PROBLEMS (Click here)


← P0031 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1) (+ P0032, P0051, P0052) (Sep 2011 – Dec 2011)P0102 Mass or Volume Air Flow Circuit Low Input (+ P0103) (Sep 2011 – Dec 2011) →