Odo/Trip Switch Malfunction
Circuit diagnosis · Vehicles built from Sep 2011
DESCRIPTION
w/ Multi-information Display:The ODO/TRIP display of the meter changes each time the ODO/TRIP switch on the light control rheostat is pressed.
- HINT:
- For more information about changing between displays, refer to the owner's manual.
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (LIGHT CONTROL RHEOSTAT) |
Operate the intelligent tester according to the display and select Data List.
Combination Meter Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
ODO/TRIP Change SW
Trip switch (ODO/TRIP switch) condition/ON or OFF
ON: Trip switch pushed
OFF: Trip switch not pushed
-
- OK:
- Switch condition (ON/OFF) can be switched by actual operation.
|
|
||||
| OK | ||
| ||
| 2. INSPECT LIGHT CONTROL RHEOSTAT (TRIP SWITCH) |
Remove the light control rheostat (Click here).

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
4 (A/B) - 1 (E)
TRIP switch ON (Pushed)
Below 200 Ω
TRIP switch OFF (Not pushed)
1 MΩ or higher
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT AND BODY GROUND) |
Disconnect the E8 ECU connector.

Disconnect the E9 switch connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
E8-4 (RSET) - E9-4 (A/B)
Always
Below 1 Ω
E8-23 (E2) - E9-1 (E)
E8-23 (E2) - Body ground
E8-4 (RSET) or E9-4 (A/B) - Body ground
10 kΩ or higher
|
|
||||
| OK | ||
| ||