2011-2013 Land Cruiser · Service Manual Engine / Hybrid / EV System

P0031 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1)

Diagnostic trouble codes · Vehicles built Sep 2011 – Dec 2011

Also covers:

Versions by build date: Sep 2011 – Dec 2011 from Jan 2012

DESCRIPTION

Refer to DTC P2195 (Click here).

HINT:
  1. When either of these DTCs are stored, the ECM enters fail-safe mode. The ECM turns off the A/F sensor heater in fail-safe mode. Fail-safe mode continues until the ignition switch is turned off.
  2. Although the DTC titles say the oxygen sensor, these DTCs relate to the Air Fuel Ratio (A/F) sensor.
  3. Sensor 1 refers to the sensor mounted in front of the Three-Way Catalytic Converter (TWC) and located near the engine assembly.

  4. The ECM provides a pulse width modulated control circuit to adjust the current through the heater. The A/F sensor heater circuit uses a relay on the +B side of the circuit.

    A160615E01

DTC Code
DTC Detection Condition
Trouble Area
P0031
P0051
The Air Fuel ratio (A/F) sensor heater current is below 0.8 A (1 trip detection logic).
  1. Open in Air Fuel Ratio (A/F) sensor heater circuit
  2. A/F sensor heater (for Bank 1, 2 Sensor 1)
  3. Integration relay (A/F relay)
  4. ECM
P0032
P0052
An Air Fuel ratio (A/F) sensor heater current failure (1 trip detection logic).
  1. Short in A/F sensor heater circuit
  2. A/F sensor heater (for Bank 1, 2 Sensor 1)
  3. Integration relay (A/F relay)
  4. ECM

HINT:
  1. Bank 1 refers to the bank that includes the No. 1 cylinder.
  2. Bank 2 refers to the bank that does not include the No. 1 cylinder.
  3. Sensor 1 refers to the sensor closest to the engine assembly.
  4. Sensor 2 refers to the sensor farthest away from the engine assembly.


MONITOR DESCRIPTION

The ECM uses information from the Air Fuel Ratio (A/F) sensor to regulate the air fuel ratio and keep it close to the stoichiometric level. This maximizes the ability of the Three-Way Catalytic Converter (TWC) to purify the exhaust gases.
The A/F sensor detects oxygen levels in the exhaust gas and transmits the information to the ECM. The inner surface of the sensor element is exposed to the outside air. The outer surface of the sensor element is exposed to the exhaust gas. The sensor element is made of platinum coated zirconia and includes an integrated heating element.
The zirconia element generates a small voltage when there is a large difference in the oxygen concentrations between the exhaust gas and outside air. The platinum coating amplifies this voltage generation.
The A/F sensor is more efficient when heated. When the exhaust gas temperature is low, the sensor cannot generate useful voltage signals without supplementary heating. The ECM regulates the supplementary heating using a duty-cycle approach to adjust the average current in the sensor heater element. If the heater current is outside the normal range, the signal transmitted by the A/F sensor becomes inaccurate, as a result, the ECM is unable to regulate air fuel ratio properly.
When the current in the A/F sensor heater is outside the normal operating range, the ECM interprets this as a malfunction in the sensor heater and stores a DTC.

WIRING DIAGRAM

Refer to DTC P2195 (Click here).

INSPECTION PROCEDURE

HINT:
Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.


1. INSPECT AIR FUEL RATIO SENSOR (HEATER RESISTANCE)
A150241E10
  1. Disconnect the Air Fuel ratio (A/F) sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    for Bank 1 Sensor 1 
    Tester Connection
    Condition
    Specified Condition
    1 (HA1A) - 2 (+B)
    20°C (68°F)
    1.8 to 3.4 Ω
    1 (HA1A) - 4 (A1A-)
    Always
    10 kΩ or higher
    for Bank 2 Sensor 1 
    Tester Connection
    Condition
    Specified Condition
    1 (HA2A) - 2 (+B)
    20°C (68°F)
    1.8 to 3.4 Ω
    1 (HA2A) - 4 (A2A-)
    Always
    10 kΩ or higher



NG
REPLACE AIR FUEL RATIO SENSOR (Click here)
OK


2. CHECK TERMINAL VOLTAGE (+B OF A/F SENSOR)
A150242E15
  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    for Bank 1 Sensor 1 
    Tester Connection
    Switch Condition
    Specified Condition
    C22-2 (+B) - Body ground
    Ignition switch ON
    11 to 14 V
    for Bank 2 Sensor 1 
    Tester Connection
    Switch Condition
    Specified Condition
    C23-2 (+B) - Body ground
    Ignition switch ON
    11 to 14 V



NG
Go to step 5
OK


3. CHECK HARNESS AND CONNECTOR (A/F SENSOR - ECM)
A182108E02
  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    C22-1 (HA1A) - C45-86 (HA1A)
    Always
    Below 1 Ω
    C23-1 (HA2A) - C45-109 (HA2A)
    Always
    Below 1 Ω
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    C22-1 (HA1A) - C46-86 (HA1A)
    Always
    Below 1 Ω
    C23-1 (HA2A) - C46-109 (HA2A)
    Always
    Below 1 Ω


    Standard Resistance (Check for Short):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    C22-1 (HA1A) or C45-86 (HA1A) - Body ground
    Always
    10 kΩ or higher
    C23-1 (HA2A) or C45-109 (HA2A) - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    C22-1 (HA1A) or C46-86 (HA1A) - Body ground
    Always
    10 kΩ or higher
    C23-1 (HA2A) or C46-109 (HA2A) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4. CHECK WHETHER DTC OUTPUT RECURS
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Clear the DTCs (Click here).

  1. Start the engine.

  1. Allow the engine to idle for 1 minute or more.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Read the DTCs.

Result 
Result
Proceed to
No output
A
P0031, P0032, P0051 or P0052
B


B
REPLACE ECM (Click here)
A

CHECK FOR INTERMITTENT PROBLEMS (Click here)

5. INSPECT INTEGRATION NO.1 RELAY (A/F RELAY)
A182246E01
  1. Remove the integration relay from the engine room relay block.

  1. Inspect the A/F fuse.

    1. Remove the A/F fuse from the integration relay.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      A/F fuse
      Always
      Below 1 Ω

    3. Reinstall the A/F fuse.

  1. Inspect the A/F relay.

    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1A-4 - 1C-1
      Battery voltage not applied to terminals 1A-2 and 1A-3
      10 kΩ or higher
      Battery voltage applied to terminals 1A-2 and 1A-3
      Below 1 Ω



NG
REPLACE INTEGRATION NO.1 RELAY
OK


6. CHECK HARNESS AND CONNECTOR (A/F SENSOR - INTEGRATION RELAY)
A182247E01
  1. Remove the integration relay from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    C22-2 (+B) - 1A-4
    Always
    Below 1 Ω
    C23-2 (+B) - 1A-4
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    C22-2 (+B) or 1A-4 - Body ground
    Always
    10 kΩ or higher
    C23-2 (+B) or 1A-4 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

CHECK ECM POWER SOURCE CIRCUIT (Click here)


← P0017 Crankshaft Position - Camshaft Position Correlation (Bank 1 Sensor B) (+ P0019) (from Jan 2012)P0031 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1) (+ 5 more codes) (from Jan 2012) →