2011-2013 Land Cruiser · Service Manual Engine / Hybrid / EV System

Cranking Holding Function Circuit

Circuit diagnosis · Vehicles built from Jan 2012

Versions by build date: Sep 2011 – Dec 2011 from Jan 2012

DESCRIPTION

The cranking holding control system provides current to the starter when the ECM detects the ignition switch start signal (STSW). When the ECM performs a firing judgment, the system cuts current to the starter. When an ECM receives the STSW signal, it turns on the ST CUT relay, which prevents flickering of the combination meter, clock, audio system, etc. Also, the ECM sends a signal to the ECM STAR terminal of the ECMl. Then the STAR output signal travels through the park/neutral position (PNP) switch to the ST relay, causing the starter to activate.
When the engine is cranking, the starter operation signal is sent to the ECM STA terminal of the ECM.
A103821E76

WIRING DIAGRAM

A263237E01
A263237E02

INSPECTION PROCEDURE


1. CHECK CRANKING
  1. Check the cranking of the engine.

    Result:
    Test Result
    Proceed to
    Cranking possible and holding control operates
    A
    Does not crank
    B
    Cranking possible but holding control does not operate
    C



B
Go to step 2

C
Go to step 11
A

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

2. READ VALUE USING INTELLIGENT TESTER (STARTER SIGNAL)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the intelligent tester on.

  1. Enter the following menus: Powertrain / Engine / Data List / Starter Signal.

  1. Read the values.

  1. Check the result when the ignition switch is turned to ON and when the engine is started.

    OK:
    Ignition Switch Condition
    Display (Starter Signal)
    ON
    OFF
    Engine started
    ON



NG
Go to step 7
OK


3. INSPECT STARTER RELAY (ST)
  1. Inspect the starter relay (ST) (Click here).



NG
REPLACE STARTER RELAY (ST)
OK


4. CHECK HARNESS AND CONNECTOR (PNP SWITCH - ST RELAY)
A275265E02
  1. Disconnect the Park/Neutral Position (PNP) switch.

  1. Remove the ST relay from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    Tester Connection
    Condition
    Specified Condition
    ST relay (1) - C24-5
    Always
    Below 1 Ω

    Standard Resistance (Check for Short):
    Tester Connection
    Condition
    Specified Condition
    ST relay (1) or D24-5 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5. CHECK HARNESS AND CONNECTOR (POWER SOURCE)
A275266E02
  1. Remove the ST relay from the engine room relay block.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    ST relay (2) - ST relay (5)
    Always
    11 to 14 V



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (STARTER RELAY (ST) - BATTERY, BODY GROUND)
OK


6. INSPECT STARTER
  1. Inspect the starter (Click here).

    Result:
    Test Result
    Proceed to
    OK
    A
    NG
    B



B
REPLACE STARTER (Click here)
A

REPAIR OR REPLACE HARNESS OR CONNECTOR (STARTER - STARTER RELAY (ST), BATTERY)

7. INSPECT STARTER CUT RELAY (ST CUT)
  1. Inspect the starter cut relay (ST CUT) (Click here).



NG
REPLACE STARTER CUT RELAY (ST CUT)
OK


8. CHECK HARNESS AND CONNECTOR (ST CUT RELAY - PNP SWITCH, ECM)
A180101E13
  1. Remove the starter cut relay (ST CUT) from the engine room relay block.

  1. Disconnect the PNP switch connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    ST CUT relay (5) - C45-51 (STAR)
    Always
    Below 1 Ω
    ST CUT relay (3) - C24-4
    Always
    Below 1 Ω
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    ST CUT relay (5) - C46-51 (STAR)
    Always
    Below 1 Ω
    ST CUT relay (3) - C24-4
    Always
    Below 1 Ω


    Standard Resistance (Check for Short):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    ST CUT relay (5) or C45-51 (STAR) - Body ground
    Always
    10 kΩ or higher
    ST CUT relay (3) or C24-4 - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    ST CUT relay (5) or C46-51 (STAR) - Body ground
    Always
    10 kΩ or higher
    ST CUT relay (3) or C24-4 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9. INSPECT PARK/NEUTRAL POSITION SWITCH

  1. C160109E06
    Inspect the Park/Neutral Position (PNP) switch.
    1. Disconnect the PNP switch connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      4 (B) - 5 (L)
      Shift lever in P
      Below 1 Ω
      Shift lever in N
      Below 1 Ω



NG
REPLACE PARK/NEUTRAL POSITION SWITCH ASSEMBLY (Click here)
OK


10. CHECK HARNESS AND CONNECTOR (PNP SWITCH - ECM)
A179964E04
  1. Disconnect the PNP switch connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    C24-5 - A38-48 (STA)
    Always
    Below 1 Ω
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    C24-5 - A52-48 (STA)
    Always
    Below 1 Ω


    Standard Resistance (Check for Short):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    C24-5 or A38-48 (STA) - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    C24-5 or A52-48 (STA) - Body ground
    Always
    10 kΩ or higher

    Result 
    Result
    Proceed to
    NG
    A
    OK
    B



B
Go to step 13
A

REPAIR OR REPLACE HARNESS OR CONNECTOR

11. CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - ECM)
A175400E04
  1. Disconnect the main body ECU connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    E4-4 (STSW) - A38-14 (STSW)
    Always
    Below 1 Ω
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    E4-4 (STSW) - A52-14 (STSW)
    Always
    Below 1 Ω


    Standard Resistance (Check for Short):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    E4-4 (STSW) or A38-14 (STSW) - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    E4-4 (STSW) or A52-14 (STSW) - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


12. CHECK HARNESS AND CONNECTOR (ST CUT RELAY - PNP SWITCH, ECM)
A180101E13
  1. Remove the starter cut relay (ST CUT) from the engine room relay block.

  1. Disconnect the PNP switch connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance (Check for Open):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    ST CUT relay (5) - C45-51 (STAR)
    Always
    Below 1 Ω
    ST CUT relay (3) - C24-4
    Always
    Below 1 Ω
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    ST CUT relay (5) - C46-51 (STAR)
    Always
    Below 1 Ω
    ST CUT relay (3) - C24-4
    Always
    Below 1 Ω


    Standard Resistance (Check for Short):
    for LHD 
    Tester Connection
    Condition
    Specified Condition
    ST CUT relay (5) or C45-51 (STAR) - Body ground
    Always
    10 kΩ or higher
    ST CUT relay (3) or C24-4 - Body ground
    Always
    10 kΩ or higher
    for RHD 
    Tester Connection
    Condition
    Specified Condition
    ST CUT relay (5) or C46-51 (STAR) - Body ground
    Always
    10 kΩ or higher
    ST CUT relay (3) or C24-4 - Body ground
    Always
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)

13. REPLACE ECM
  1. Replace the ECM (Click here).


NEXT


14. CONFIRM WHETHER MALFUNCTION HAS BEEN SUCCESSFULLY REPAIRED
  1. Check the starter operation.

    OK:
    Malfunction has been repaired successfully.



NG
GO TO ENTRY AND START SYSTEM (ENGINE DOES NOT START) (Click here)
OK

END


← Cranking Holding Function Circuit (Sep 2011 – Dec 2011)Injector Circuit (Sep 2011 – Dec 2011) →