ECM Communication Stop Mode
Circuit diagnosis · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
| Detection Item |
Symptom |
Trouble Area |
| ECM Communication Stop Mode |
|
|
WIRING DIAGRAM






INSPECTION PROCEDURE
| 1. CHECK HARNESS AND CONNECTOR (ECM - BATTERY AND BODY GROUND) |
Disconnect the A52 and C46 ECU connectors.


Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for 2UZ-FE Tester Connection
Condition
Specified Condition
C46-81 (E1) - Body ground
Always
Below 1 Ω
C46-42 (E02) - Body ground
Always
Below 1 Ω
C46-43 (E01) - Body ground
Always
Below 1 Ω
C46-82 (ME01) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
for 2UZ-FE Tester Connection
Condition
Specified Condition
A52-1 (BATT) - Body ground
Always
11 to 14 V
A52-2 (+B2) - Body ground
Battery positive (+) voltage applied to terminal MREL
11 to 14 V
A52-3 (+B) - Body ground
Battery positive (+) voltage applied to terminal MREL
11 to 14 V
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for 1GR-FE Tester Connection
Condition
Specified Condition
C46-81 (E1) - Body ground
Always
Below 1 Ω
C46-21 (E02) - Body ground
Always
Below 1 Ω
C46-22 (E01) - Body ground
Always
Below 1 Ω
C46-20 (ME01) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
for 1GR-FE Tester Connection
Condition
Specified Condition
A52-20 (BATT) - Body ground
Always
11 to 14 V
A52-1 (+B2) - Body ground
Battery positive (+) voltage applied to terminal MREL
11 to 14 V
A52-2 (+B) - Body ground
Battery positive (+) voltage applied to terminal MREL
11 to 14 V
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for 1VD-FTV Tester Connection
Condition
Specified Condition
C46-81 (E1) - Body ground
Always
Below 1 Ω
C46-21 (E02) - Body ground
Always
Below 1 Ω
C46-22 (E01) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
for 1VD-FTV Tester Connection
Condition
Specified Condition
A52-20 (BATT) - Body ground
Always
11 to 14 V
A52-44 (MREL) - Body ground
Ignition switch ON
11 to 14 V
A52-2 (+B) - Body ground
Battery positive (+) voltage applied to terminal MREL
11 to 14 V
| Result |
Proceed to |
| OK (for 2UZ-FE) |
A |
| OK (for 1GR-FE) |
B |
| OK (for 1VD-FTV) |
C |
| NG |
D |
|
|
||||
|
|
||||
|
|
||||
| A | ||
| ||