Open in CAN Main Wire
Circuit diagnosis · Vehicles built Sep 2011 – Dec 2011
Versions by build date: Sep 2011 – Dec 2011 from Jan 2012
DESCRIPTION
There may be an open circuit in the CAN main wire and/or DLC3 branch wire when the resistance between terminals 6 (CANH) and 14 (CANL) of the DLC3 is 69 Ω or higher.| Symptom |
Trouble Area |
| Resistance between terminals 6 (CANH) and 14 (CANL) of the DLC3 is 69 Ω or higher. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- Operating the ignition switch, any switches or any doors triggers related ECU and sensor communication with the CAN, which causes resistance variation.
| 1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
Disconnect the cable from the negative (-) battery terminal before measuring the resistances of the main wire and the branch wire.
- CAUTION:
- For vehicles with an SRS system:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).
| NEXT | |
| 2. CHECK DLC3 |
Measure the resistance according to the value(s) in the table below.

Result Tester Connection
Switch Condition
Measured Resistance
Proceed to
E22-6 (CANH) - E22-14 (CANL)
Ignition switch off
108 to 132 Ω
OK
E22-6 (CANH) - E22-14 (CANL)
Ignition switch off
132 Ω or higher
NG
- NOTICE:
- When the measured value is 132 Ω or higher and a CAN communication system diagnostic trouble code is output, there may be a fault besides disconnection of the DLC3 branch wire. For that reason, troubleshooting should be performed again from "How to Proceed with Troubleshooting" (Click here) after repairing the trouble area.
|
|
||||
| OK | |
| 3. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 2 JUNCTION CONNECTOR - ECM) |
Disconnect the E69 No. 2 junction connector connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E69-4 (CANH) - E69-15 (CANL)
Ignition switch off
108 to 132 Ω
|
|
||||
| OK | |
| 4. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 2 JUNCTION CONNECTOR - COMBINATION METER) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E69-1 (CANH) - E69-12 (CANL)
Ignition switch off
108 to 132 Ω
|
|
||||
| OK | ||
| ||
| 5. CONNECT CONNECTOR |
Reconnect the E69 No. 2 junction connector connector.
| NEXT | |
| 6. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - ECM) |
Disconnect the E72 No. 1 junction connector connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E72-2 (CANH) - E72-13 (CANL)
Ignition switch off
108 to 132 Ω
|
|
||||
| OK | |
| 7. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 1 JUNCTION CONNECTOR - NO. 2 JUNCTION CONNECTOR) |
![]() ![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E72-1 (CANH) - E72-12 (CANL)
Ignition switch off
108 to 132 Ω
|
|
||||
| OK | ||
| ||
| 8. CONNECT CONNECTOR |
Reconnect the E72 No. 1 junction connector connector.
| NEXT | |
| 9. CHECK FOR OPEN IN CAN BUS MAIN WIRE (ECM - NO. 1 JUNCTION CONNECTOR) |
Disconnect the A52 ECM connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for 2UZ-FE Tester Connection
Switch Condition
Specified Condition
A52-10 (CANH) - A52-11 (CANL)
Ignition switch off
108 to 132 Ω
for 1GR-FE, 1VD-FTV Tester Connection
Switch Condition
Specified Condition
A52-41 (CANH) - A52-49 (CANL)
Ignition switch off
108 to 132 Ω
Result Result
Proceed to
OK (for 2UZ-FE)
A
OK (for 1GR-FE)
B
OK (for 1VD-FTV)
C
NG
D
|
|
||||
|
|
||||
|
|
||||
| A | ||
| ||
| 10. CONNECT CONNECTOR |
Reconnect the E69 No. 2 junction connector connector.
| NEXT | |
| 11. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 3 JUNCTION CONNECTOR - COMBINATION METER) |
Disconnect the E75 No. 3 junction connector connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E75-3 (CANH) - E75-14 (CANL)
Ignition switch off
108 to 132 Ω
|
|
||||
| OK | |
| 12. CHECK FOR OPEN IN CAN BUS MAIN WIRE (NO. 2 JUNCTION CONNECTOR - NO. 3 JUNCTION CONNECTOR) |
Measure the resistance according to the value(s) in the table below.

- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E75-1 (CANH) - E75-12 (CANL)
Ignition switch off
108 to 132 Ω
|
|
||||
| OK | ||
| ||
| 13. CONNECT CONNECTOR |
Reconnect the E75 No. 3 junction connector connector.
| NEXT | |
| 14. CHECK FOR OPEN IN CAN BUS MAIN WIRE (COMBINATION METER - NO. 3 JUNCTION CONNECTOR) |
Disconnect the E7 combination meter connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
E7-25 (CANH) - E7-26 (CANL)
Ignition switch off
108 to 132 Ω
Result Result
Proceed to
OK (w/ Multi-information Display)
A
OK (w/o Multi-information Display)
B
NG
C
|
|
||||
|
|
||||
| A | ||
| ||