When the ignition switch is turned to ON, battery voltage is applied to the IGSW of the ECM. The output signal from the MREL terminal of the ECM causes a current to flow to the coil, closing the contacts of the integration relay (EFI relay) and supplying power to either terminal +B or +B2 of the ECM.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
Remove the integration relay from the engine room relay block.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1C-1 - Body ground | Always | 11 to 14 V |
OK
NG
Inspect the integration relay (See page Engine / Hybrid System>1GR-FE (ENGINE CONTROL)>RELAY>ON-VEHICLE INSPECTION).
OK
NG
Check the harness and the connectors between the integration relay and the ECM.
Remove the integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A38-34 (MREL) - 1B-2 | Always | Below 1 Ω |
| A38-3 (+B) - 1B-4 | Always | Below 1 Ω |
| A38-2 (+B2) - 1B-4 | Always | Below 1 Ω |
| A38-34 (MREL) or 1B-2 - Body ground | Always | 10 kΩ or higher |
| A38-3 (+B) or 1B-4 - Body ground | Always | 10 kΩ or higher |
| A38-2 (+B2) or 1B-4 - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A52-34 (MREL) - 1B-2 | Always | Below 1 Ω |
| A52-3 (+B) - 1B-4 | Always | Below 1 Ω |
| A52-2 (+B2) - 1B-4 | Always | Below 1 Ω |
| A52-34 (MREL) or 1B-2 - Body ground | Always | 10 kΩ or higher |
| A52-3 (+B) or 1B-4 - Body ground | Always | 10 kΩ or higher |
| A52-2 (+B2) or 1B-4 - Body ground | Always | 10 kΩ or higher |
Check the harness and connectors between the integration relay and body ground.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1B-3 - Body ground | Always | Below 1 Ω |
OK
NG
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C45-81 (E1) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| C46-81 (E1) - Body ground | Always | Below 1 Ω |
OK
NG
Disconnect the ECM connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-28 (IGSW) - C45-81 (E1) | Ignition switch ON | 11 to 14 V |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A52-28 (IGSW) - C46-81 (E1) | Ignition switch ON | 11 to 14 V |
OK
NG
Remove the IGN fuse from the engine room relay block.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGN fuse | Always | Below 1 Ω |
OK
NG
Remove the integration relay from the engine room relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1B-8 - A38-28 (IGSW) | Always | Below 1 Ω |
| 1B-8 or A38-28 (IGSW) - Body ground | Always | 10 kΩ or higher |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1B-8 - A52-28 (IGSW) | Always | Below 1 Ω |
| 1B-8 or A52-28 (IGSW) - Body ground | Always | 10 kΩ or higher |
OK
NG
| Result | Proceed to |
|---|---|
| w/ Entry and Start System | A |
| w/o Entry and Start System | B |
A
B
Remove the integration relay from the engine room relay block.
Disconnect the E2 main body ECU connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E2-11 (IG2D) - 1B-6 | Always | Below 1 Ω |
| E2-11 (IG2D) or 1B-6 - Body ground | Always | 10 kΩ or higher |
OK
NG
Check the entry and start system (See page Vehicle Interior>THEFT DETERRENT / KEYLESS ENTRY>ENTRY AND START SYSTEM(for Start Function)>Power Source Mode does not Change).
OK
NG
Remove the integration relay from the engine room relay block.
Disconnect the E93 ignition switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E93-6 (IG2) - 1B-6 | Always | Below 1 Ω |
| 1B-7 - Body ground | Always | Below 1 Ω |
| E93-6 (IG2) or 1B-6 - Body ground | Always | 10 kΩ or higher |
OK
NG
Inspect the ignition switch assembly (See page Engine / Hybrid System>1GR-FE (STARTING)>IGNITION SWITCH>INSPECTION).
OK
NG