Use the same procedures for the RHD and LHD.
The procedures listed below are the LHD side.
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See page General>INTRODUCTION>REPAIR INSTRUCTION>INITIALIZATION).
67913B
2.REMOVE FRONT DOOR SCUFF PLATE RH
55448A
3.REMOVE NO. 1 INSTRUMENT PANEL FINISH CUSHION
55402C
4.REMOVE LOWER INSTRUMENT PANEL PAD SUB-ASSEMBLY RH
55607
5.REMOVE NO. 2 INSTRUMENT PANEL UNDER COVER SUB-ASSEMBLY (w/ Floor Under Cover)
73990
6.REMOVE FRONT PASSENGER SIDE KNEE AIRBAG ASSEMBLY
Remove the 4 bolts.
Detach the 4 claws and remove the front passenger side knee airbag.
Disconnect the connector.
When handling the airbag connector, take care not to damage the airbag wire harness.