Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) › 2014.08–2015.08
RM2660E _58 Vehicle Interior _052847 HEATING / AIR CONDITIONING _0255699 AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) C

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  B1423/23  Pressure Sensor Circuit  


DESCRIPTION

This DTC is output when refrigerant pressure is extremely low (-0.4566 MPaG (-4.6 kgf/cm2, -66 psi) or less) or extremely high (3.2943 MPaG (33.6 kgf/cm2, 477 psi) or more). The air conditioner pressure sensor, which is installed on the pipe of the high pressure side to detect refrigerant pressure, outputs the refrigerant pressure signal to the air conditioning amplifier assembly. The air conditioning amplifier assembly converts the signal to pressure according to the sensor characteristics to control the compressor.

HINT:

Be sure to check the refrigerant volume first when this DTC is output because this DTC can also be output if there is no refrigerant in the cycle.


DTC Code DTC Detection Condition Trouble Area
B1423/23
·

An open or short in the air conditioner pressure sensor circuit

·

Refrigerant pressure on the high pressure side is extremely low (-0.4566 MPaG (-4.6 kgf/cm2, -66 psi) or less) or extremely high (3.2943 MPaG (33.6 kgf/cm2, 477 psi) or more)


·

Air conditioner pressure sensor

·

Harness or connector

·

Cooler expansion valve (blocked, stuck)

·

Cooler condenser assembly (blocked, deterioration of cooling capacity due to dirt)

·

Cooler dryer (moisture in the refrigerant cycle cannot be absorbed)

·

Condenser fan (condenser cannot be cooled down)

·

Air conditioning system (leaks, blocked)

·

Refrigerant pipe line

·

Air conditioning amplifier assembly



WIRING DIAGRAM

E156766E07
2.475,0.44 2.580,0.608 0.105,0.168 10 3 2.475,0.835 2.580,1.003 0.105,0.168 10 1 2.475,1.228 2.580,1.396 0.105,0.168 10 2 4.393,0.268 4.714,0.426 0.321,0.158 10 27*1 4.393,0.436 4.714,0.594 0.321,0.158 10 30*2 4.391,0.691 4.694,0.853 0.303,0.161 10 16*1 4.391,0.849 4.694,1.010 0.303,0.161 10 13*2 4.412,1.123 4.729,1.291 0.317,0.168 10 20*1 4.478,1.263 4.736,1.431 0.258,0.168 10 9*2 2.277,0.539 2.468,0.708 0.191,0.168 10 + 2.277,0.934 2.438,1.102 0.161,0.168 10 - 2.173,1.327 2.397,1.496 0.223,0.168 10 PR 0.992,1.771 1.289,1.939 0.297,0.168 10 A13 0.992,1.939 3.044,2.107 2.052,0.168 10 Air Conditioner Pressure Sensor 4.735,1.771 5.138,1.939 0.404,0.168 10 E35*1 4.735,1.93 5.138,2.098 0.404,0.168 10 E81*2 4.735,2.074 7.162,2.243 2.427,0.168 10 Air Conditioning Amplifier Assembly 4.795,0.539 5.156,0.708 0.361,0.168 10 S5-1 4.795,0.934 5.156,1.102 0.361,0.168 10 SG-2 4.798,1.327 5.123,1.496 0.325,0.168 10 PRE 0.054,2.247 1.259,2.431 1.204,0.184 10 *1: w/ Rear Heater 0.054,2.517 1.304,2.701 1.249,0.184 10 *2: w/o Rear Heater

PROCEDURE

1.CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
U166035E02
2.115,2.344 2.563,2.604 false 0.302,0.094 2.646,0.417 2.344,0.323 10 false Front view of wire harness connector: (to Air Conditioner Pressure Sensor) 0.51,1.594 0.823,1.802 0.313,0.208 10 false A13 2.635,2.542 2.875,2.771 0.24,0.229 10 false +

a.

Disconnect the A13 air conditioner pressure sensor connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Switch Condition Specified Condition
A13-3 (+) - Body ground Engine switch on (IG) 4.4 to 5.5 V




OK

2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)

NG

5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - PRESSURE SENSOR)
2.CHECK HARNESS AND CONNECTOR (GROUND CIRCUIT)
U166036E02
1.271,2.313 0.698,2.792 false 0.313,0.188 2.646,0.531 2.333,0.344 10 false Front view of wire harness connector: (to Air Conditioner Pressure Sensor) 0.396,1.531 0.688,1.729 0.292,0.198 10 false A13 0.563,2.75 0.708,2.948 0.146,0.198 10 false -

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A13-1 (-) - Body ground Always Below 1 Ω




OK

3.INSPECT AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - PRESSURE SENSOR)
3.INSPECT AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Reconnect the A13 pressure sensor connector.


b.

Remove the air conditioning amplifier with its connectors still connected.

E349663E01
2.313,0.802 2.677,1.042 0.365,0.24 5.188,0.51 5.552,0.75 0.365,0.24 2.26,2.396 2.677,1.688 false 6.104,1.938 5.667,1.198 false 0.135,0.104 2.469,0.51 2.333,0.406 10 false Component with harness connected: (Air Conditioning Amplifier Assembly) 2.375,0.844 2.729,1.063 0.354,0.219 10 false E35 2.708,0.833 3.021,1.031 0.313,0.198 10 false *1 2.01,2.417 2.365,2.635 0.354,0.219 10 false PRE 5.229,0.542 5.583,0.76 0.354,0.219 10 false E81 5.594,0.531 5.906,0.729 0.313,0.198 10 false *2 5.99,1.979 6.344,2.198 0.354,0.219 10 false PRE 4.042,2.052 5.396,2.302 1.354,0.25 10 false *1: w/ Rear Heater 4.042,2.396 5.396,2.646 1.354,0.25 10 false *2: w/o Rear Heater

Standard Voltage:
w/ Rear Heater:
Tester Connection Switch Condition Specified Condition
E35-20 (PRE) - Body ground
·

Engine switch on (IG)

·

A/C switch off


0.7 to 4.8 V

w/o Rear Heater:
Tester Connection Switch Condition Specified Condition
E81-9 (PRE) - Body ground
·

Engine switch on (IG)

·

A/C switch off


0.7 to 4.8 V


HINT:

If the measured voltage is not within the normal range, there may be a malfunction in the air conditioning amplifier assembly, air conditioner pressure sensor, or wire harness. It is also possible that the amount of refrigerant may not be appropriate.




OK

4.INSPECT AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

NG

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - PRESSURE SENSOR)
4.INSPECT AIR CONDITIONER PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
a.

Measure the voltage when the following conditions are satisfied.

Item Condition
Engine Speed 1500 rpm
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch ON
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:
·

If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.8 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe operation.

·

It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the problem symptom may recur after a while.



HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


i.

Measure the voltage according to the value(s) in the table below.

E349663E02
2.313,0.802 2.677,1.042 0.365,0.24 5.188,0.51 5.552,0.75 0.365,0.24 2.26,2.396 2.677,1.688 false 6.094,1.896 5.656,1.156 false 0.135,0.104 2.469,0.51 2.333,0.406 10 false Component with harness connected: (Air Conditioning Amplifier Assembly) 2.375,0.844 2.729,1.063 0.354,0.219 10 false E35 2.708,0.833 3.021,1.031 0.313,0.198 10 false *1 2.01,2.417 2.365,2.635 0.354,0.219 10 false PRE 5.229,0.542 5.583,0.76 0.354,0.219 10 false E81 5.594,0.531 5.906,0.729 0.313,0.198 10 false *2 6.01,1.927 6.365,2.146 0.354,0.219 10 false PRE 4.042,2.052 5.396,2.302 1.354,0.25 10 false *1: w/ Rear Heater 4.042,2.396 5.396,2.646 1.354,0.25 10 false *2: w/o Rear Heater

Standard Voltage:
w/ Rear Heater:
Tester Connection Switch Condition Specified Condition
E35-20 (PRE) - Body ground
·

Engine switch on (IG)

·

A/C switch on


0.7 to 4.8 V

w/o Rear Heater:
Tester Connection Switch Condition Specified Condition
B81-9 (PRE) - Body ground
·

Engine switch on (IG)

·

A/C switch on


0.7 to 4.8 V





OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

13.INSPECT CONDENSER FAN
5.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - PRESSURE SENSOR)
E349664E01
0.792,1.156 1.135,1.385 0.344,0.229 2.281,2.604 2.594,2.802 0.313,0.198 5.479,1.406 5.823,1.635 0.344,0.229 1.948,1.385 2.417,1.448 false 5.656,2.531 6.073,2.969 false 2.271,4.01 1.927,4.323 false 0.188,0.104 2.479,0.521 2.292,0.417 10 false Front view of wire harness connector: (to Air Conditioner Pressure Sensor) 0.833,1.188 1.177,1.406 0.344,0.219 10 false A13 2.469,1.354 2.625,1.552 0.156,0.198 10 false + 0.219,1.833 2.635,2.229 2.417,0.396 10 false Rear view of wire harness connector: (to Air Conditioning Amplifier Assembly) 2.313,2.625 2.625,2.792 0.313,0.167 10 true E35 2.625,2.604 2.781,2.802 0.156,0.198 10 true *1 4.042,0.531 6.458,0.927 2.417,0.396 10 false Rear view of wire harness connector: (to Air Conditioning Amplifier Assembly) 5.531,1.448 5.823,1.635 0.292,0.188 10 false E81 5.854,1.438 6.01,1.635 0.156,0.198 10 false *2 6.063,3.052 6.49,3.26 0.427,0.208 10 false S5-1 4.177,3.094 5.51,3.344 1.333,0.25 10 false *1: w/ Rear Heater 4.177,3.438 5.51,3.688 1.333,0.25 10 false *2: w/o Rear Heater 1.771,4.354 2.198,4.563 0.427,0.208 10 false S5-1

a.

Disconnect the E35*1 or E81*2 amplifier connector.

HINT:

*1: w/ Rear Heater

*2: w/o Rear Heater



b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
w/ Rear Heater:
Tester Connection Condition Specified Condition
A13-3 (+) - E35-27 (S5-1) Always Below 1 Ω
E35-27 (S5-1) - Body ground Always 10 kΩ or higher

w/o Rear Heater:
Tester Connection Condition Specified Condition
A13-3 (+) - E81-30 (S5-1) Always Below 1 Ω
E81-30 (S5-1) - Body ground Always 10 kΩ or higher




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

6.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - PRESSURE SENSOR)
E349664E02
0.792,1.156 1.135,1.385 0.344,0.229 2.281,2.604 2.594,2.802 0.313,0.198 5.479,1.406 5.823,1.635 0.344,0.229 1.802,1.385 2.271,1.448 false 5.698,2.469 6.115,2.906 false 2.688,3.969 2.188,4.375 false 0.188,0.104 2.479,0.521 2.292,0.417 10 false Front view of wire harness connector: (to Air Conditioner Pressure Sensor) 0.833,1.188 1.177,1.406 0.344,0.219 10 false A13 2.344,1.375 2.573,1.573 0.229,0.198 10 false PR 0.219,1.833 2.635,2.229 2.417,0.396 10 false Rear view of wire harness connector: (to Air Conditioning Amplifier Assembly) 2.313,2.625 2.594,2.792 0.281,0.167 10 true E35 2.625,2.604 2.781,2.802 0.156,0.198 10 true *1 4.042,0.531 6.458,0.927 2.417,0.396 10 false Rear view of wire harness connector: (to Air Conditioning Amplifier Assembly) 5.531,1.448 5.823,1.635 0.292,0.188 10 false E81 5.854,1.438 6.01,1.635 0.156,0.198 10 false *2 6.031,2.938 6.458,3.146 0.427,0.208 10 false PRE 4.177,3.094 5.51,3.344 1.333,0.25 10 false *1: w/ Rear Heater 4.177,3.438 5.51,3.688 1.333,0.25 10 false *2: w/o Rear Heater 1.885,4.406 2.313,4.615 0.427,0.208 10 false PRE

a.

Disconnect the E35*1 or E81*2 amplifier connector.

HINT:

*1: w/ Rear Heater

*2: w/o Rear Heater



b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
w/ Rear Heater:
Tester Connection Condition Specified Condition
A13-1 (-) - E35-16 (SG-2) Always Below 1 Ω
E35-16 (SG-2) - Body ground Always 10 kΩ or higher

w/o Rear Heater:
Tester Connection Condition Specified Condition
A13-1 (-) - E81-13 (SG-2) Always Below 1 Ω
E81-13 (SG-2) - Body ground Always 10 kΩ or higher




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

7.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - PRESSURE SENSOR)
E349664E03
0.792,1.156 1.135,1.385 0.344,0.229 2.281,2.604 2.594,2.802 0.313,0.198 5.479,1.406 5.823,1.635 0.344,0.229 1.948,1.385 2.417,1.448 false 5.688,2.469 6.104,2.906 false 2.688,4.01 2.156,4.417 false 0.188,0.104 2.479,0.521 2.292,0.417 10 false Front view of wire harness connector: (to Air Conditioner Pressure Sensor) 0.833,1.188 1.177,1.406 0.344,0.219 10 false A13 2.469,1.354 2.75,1.552 0.281,0.198 10 false PR 0.219,1.833 2.635,2.229 2.417,0.396 10 false Rear view of wire harness connector: (to Air Conditioning Amplifier Assembly) 2.313,2.625 2.573,2.792 0.26,0.167 10 true E35 2.625,2.604 2.781,2.802 0.156,0.198 10 true *1 4.042,0.531 6.458,0.927 2.417,0.396 10 false Rear view of wire harness connector: (to Air Conditioning Amplifier Assembly) 5.531,1.448 5.823,1.635 0.292,0.188 10 false E81 5.854,1.438 6.01,1.635 0.156,0.198 10 false *2 6.125,2.948 6.552,3.156 0.427,0.208 10 false PRE 4.177,3.094 5.51,3.344 1.333,0.25 10 false *1: w/ Rear Heater 4.177,3.438 5.51,3.688 1.333,0.25 10 false *2: w/o Rear Heater 1.802,4.354 2.229,4.563 0.427,0.208 10 false PRE

a.

Disconnect the E35*1 or E81*2 amplifier connector.

HINT:

*1: w/ Rear Heater

*2: w/o Rear Heater



b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
w/ Rear Heater:
Tester Connection Condition Specified Condition
A13-2 (PR) - E35-20 (PRE) Always Below 1 Ω
E35-20 (PRE) - Body ground Always 10 kΩ or higher

w/o Rear Heater:
Tester Connection Condition Specified Condition
A13-2 (PR) - E81-9 (PRE) Always Below 1 Ω
E81-9 (PRE) - Body ground Always 10 kΩ or higher




OK

8.INSPECT FOR AIR CONDITIONING SYSTEM LEAK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

8.INSPECT FOR AIR CONDITIONING SYSTEM LEAK
a.

Install the manifold gauge set.


b.

Recover the refrigerant from the air conditioning system using a refrigerant recovery unit.


c.

Evacuate the air conditioning system and check that vacuum can be maintained in it.

OK:

Vacuum can be maintained in the air conditioning system.


HINT:

If vacuum cannot be maintained in the air conditioning system, refrigerant may be leaking from it. In this case, it is necessary to repair or replace the leaking part of the air conditioning system.




OK

9.CHARGE REFRIGERANT

NG

12.REPAIR AIR CONDITIONING SYSTEM LEAK
9.CHARGE REFRIGERANT
a.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).



NEXT

10.RECHECK DTC
10.RECHECK DTC
a.

Recheck for the DTC when the following conditions are satisfied.

Item Condition
Engine Speed 1500 rpm
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch ON
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. Therefore, it is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning system operates for a while.


HINT:

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.


OK:

DTC B1423 is not output.


NOTICE:

If the DTC was output due to an insufficient or excessive amount of refrigerant, the problem may have been solved after performing the previous step. However, the root cause of insufficient refrigerant may be refrigerant leaks. The root cause of excessive refrigerant may be adding refrigerant when the level was insufficient. Therefore, identify and repair the area where refrigerant leaks as necessary.




OK

END

NG

11.CHECK AIR CONDITIONER PRESSURE SENSOR
11.CHECK AIR CONDITIONER PRESSURE SENSOR
E349665E01
2.5,1.302 2.865,1.552 0.365,0.25 2.521,2.344 2.885,2.594 0.365,0.25 1.698,1.583 1.813,2.083 1.813,2.083 1.698,2.083 false 2.146,1.656 2.396,1.958 2.396,1.958 2.49,1.958 false 1.417,2.583 1.542,3.094 1.542,3.094 1.646,3.094 false 1.156,2.594 1.302,3.104 1.302,3.104 1.177,3.104 false 0.146,0.115 2.448,0.51 2.302,0.396 10 false Component with harness connected: (Air Conditioning Amplifier Assembly) 4.781,0.375 5.604,0.667 0.823,0.292 10 false (V)Voltage 2.552,1.333 2.896,1.531 0.344,0.198 10 false E35 1.333,2 1.781,2.208 0.448,0.208 10 false SG-2 2.542,1.885 2.99,2.094 0.448,0.208 10 false PRE 2.896,1.354 3.146,1.552 0.25,0.198 10 false *1 2.583,2.385 2.927,2.583 0.344,0.198 10 false E81 2.938,2.385 3.188,2.583 0.25,0.198 10 false *2 1.719,3.01 2.167,3.219 0.448,0.208 10 false PRE 0.823,3.031 1.271,3.24 0.448,0.208 10 false SG-2 4.5,1.802 4.771,1.979 0.271,0.177 10 false 0.5 4.354,0.688 4.75,0.865 0.396,0.177 10 false 4.834 4.344,1.583 4.74,1.76 0.396,0.177 10 false 1.030 4.49,0.542 4.76,0.719 0.271,0.177 10 false 4.9 4.5,1.948 4.771,2.125 0.271,0.177 10 false 0.1 5.021,2.156 5.177,2.333 0.156,0.177 10 false 0 5.208,2.156 5.521,2.344 0.313,0.188 10 false 0.39 5.229,2.302 5.542,2.49 0.313,0.188 10 false (57) 5.99,2.156 6.375,2.344 0.385,0.188 10 false 3.187 6.01,2.302 6.365,2.49 0.354,0.188 10 false (463) 6.625,2.146 7.01,2.333 0.385,0.188 10 false MPa 6.625,2.281 6.979,2.469 0.354,0.188 10 false (psi) 5.188,2.521 6.479,2.719 1.292,0.198 10 false Refrigerant Pressure 4.021,2.896 5.24,3.104 1.219,0.208 10 false *1: w/ Rear Heater 4.031,3.156 5.25,3.365 1.219,0.208 10 false *2: w/o Rear Heater

a.

Install the manifold gauge set.


b.

Reconnect the A13 air conditioner pressure sensor connector.


c.

Remove the air conditioning amplifier assembly with its connectors still connected.


d.

Turn the engine switch on (IG).


e.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
w/ Rear Heater:
Tester Connection Condition Specified Condition
E35-20 (PRE) - E35-16 (SG-2) Refrigerant pressure:
Normal pressure (less than 3.0732 MPa [31.4 kgf/cm2, 445 psi] and more than 0.1762 MPa [1.8 kgf/cm2, 25 psi])
1.0 to 4.8 V
Refrigerant pressure:
Abnormal (less than 0.1762 MPa [1.8 kgf/cm2, 25 psi])
Below 1 V
Refrigerant pressure:
Abnormal (more than 3.0732 MPa [31.4 kgf/cm2, 445 psi])
4.8 V or higher

w/o Rear Heater:
Tester Connection Condition Specified Condition
E81-9 (PRE) - E81-13 (SG-2) Refrigerant pressure:
Normal pressure (less than 3.0732 MPa [31.4 kgf/cm2, 445 psi] and more than 0.1762 MPa [1.8 kgf/cm2, 25 psi])
1.0 to 4.8 V
Refrigerant pressure:
Abnormal (less than 0.1762 MPa [1.8 kgf/cm2, 25 psi])
Below 1 V
Refrigerant pressure:
Abnormal (more than 3.0732 MPa [31.4 kgf/cm2, 445 psi])
4.8 V or higher




OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

12.REPAIR AIR CONDITIONING SYSTEM LEAK
a.

Identify the area where refrigerant leaks (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>ON-VEHICLE INSPECTION).


b.

Repair the identified area of the air conditioning system.


c.

Evacuate the air conditioning system.



NEXT

13.INSPECT CONDENSER FAN
NOTICE:

For vehicles without an condenser fan, go to "CHARGE REFRIGERANT".


a.

Inspect that the condenser fan operates normally (See page Vehicle Interior>HEATING / AIR CONDITIONING>CONDENSER FAN>INSPECTION).



OK

14.CHARGE REFRIGERANT

NG

14.CHARGE REFRIGERANT
a.

Use a refrigerant recovery unit to recover refrigerant.


b.

Evacuate the air conditioning system.


c.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).

HINT:

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC.




NEXT

15.RECHECK DTC
15.RECHECK DTC
a.

Recheck for the DTC when the following conditions are satisfied.

Item Condition
Engine Speed 1500 rpm
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch ON
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. Therefore, it is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning system operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant is added and the system has not been properly evacuated (insufficient vacuum time), moisture in the air remaining in the system will freeze in the expansion valve, blocking the flow on the high pressure side. Therefore, in order to confirm the problem, recover the refrigerant and properly evacuate the system. Add an appropriate amount of refrigerant, and check for the DTC. If the DTC is not output after this procedure, it indicates that the cooler dryer in the condenser is not able to absorb moisture in the refrigerant cycle. In this case, to complete the repair it is necessary to replace the cooler dryer.



OK:

DTC B1423 is not output.




OK

NG

16.REPLACE COOLER EXPANSION VALVE
16.REPLACE COOLER EXPANSION VALVE
a.

Replace the cooler expansion valve with a normal one.

for LHD (See page Vehicle Interior>HEATING / AIR CONDITIONING>FRONT AIR CONDITIONING UNIT (for LHD)>DISASSEMBLY)

for RHD (See page Vehicle Interior>HEATING / AIR CONDITIONING>FRONT AIR CONDITIONING UNIT (for RHD)>DISASSEMBLY)

HINT:

Replace the cooler expansion valve with a normal one because the cooler expansion valve is either stuck or clogged.




NEXT

17.CHARGE REFRIGERANT
17.CHARGE REFRIGERANT
a.

Add an appropriate amount of refrigerant (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>REPLACEMENT).



NEXT

18.RECHECK DTC
18.RECHECK DTC
a.

Recheck for the DTC when the following conditions are satisfied.

Item Condition
Engine Speed 1500 rpm
Vehicle Doors Fully open
Temperature Setting MAX COLD
Blower Speed HI
A/C Switch ON
R/F Switch RECIRCULATION
Interior Temperature 25 to 35°C (77 to 95°F)

NOTICE:

If refrigerant pressure on the high pressure side becomes high, the DTC will be stored. Therefore, it is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the DTC may be stored after the air conditioning system operates for a while.


HINT:
·

When the outside air temperature is low (below -1.5°C (29.3°F)), the compressor stops due to operation of the ambient temperature sensor and the evaporator temperature sensor to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.

·

If refrigerant pressure is not normal after replacing the expansion valve with a normal one, the condenser or pipes may be clogged due to dirt, dust or other contaminants. In this case, clean or replace the condenser or pipes.



OK:

DTC B1423 is not output.




OK

END

NG

REPLACE COOLER CONDENSER ASSEMBLY