The cooler thermistor (duct sensor LH*1 or RH*2) detects the duct temperature and sends the appropriate signals to the air conditioning amplifier assembly.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1467/67 | An open or short in the air duct temperature sensor LH*1 or RH*2 circuit. | ·
Cooler thermistor (duct sensor LH)*1 ·
Cooler thermistor (duct sensor RH)*2 ·
Harness or connector ·
Air conditioning amplifier assembly |
for LHD:
for RHD:
*1: for LHD
*2: for RHD
Use the Data List to check if the cooler thermistor (duct sensor LH*1 or RH*2) is functioning properly (See page Vehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System)>DATA LIST / ACTIVE TEST).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Foot Duct Sensor (Rear D) | Cooler thermistor (duct sensor LH*1 or RH*2) / Min.: -12.7°C (9.14°F), Max.: 76.55°C (169.79°F) | Cooler thermistor (duct sensor LH*1 or RH*2) displayed | Cooler thermistor (duct sensor LH*1 or RH*2) system malfunction:
·
Open in the circuit: -12.7°C (9.14°F) ·
Short in the circuit: 76.55°C (169.79°F) |
The display is as specified in the normal condition.
OK
NG
Remove the cooler thermistor (duct sensor LH*1 or RH*2) (See page Vehicle Interior>HEATING / AIR CONDITIONING>DUCT TEMPERATURE SENSOR (w/ Heater)>REMOVAL).
Inspect the cooler thermistor (duct sensor LH*1 or RH*2) (See page Vehicle Interior>HEATING / AIR CONDITIONING>DUCT TEMPERATURE SENSOR (w/ Heater)>INSPECTION)
OK
NG
for LHD:
Disconnect the K21 cooler thermistor (duct sensor LH) connector.
Disconnect the E35 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E35-18 (RHTL) - K21-1 | Always | Below 1 Ω |
| E35-31 (SGND) - K21-2 | Always | Below 1 Ω |
| E35-18 (RHTL) - E35-31 (SGND) | Always | 10 kΩ or higher |
| E35-18 (RHTL) or K21-1 - Body ground | Always | 10 kΩ or higher |
| E35-31 (SGND) or K21-2 - Body ground | Always | 10 kΩ or higher |
for RHD:
Disconnect the L12 cooler thermistor (duct sensor RH) connector.
Disconnect the E35 air conditioning amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E35-17 (RHTR) - L12-1 | Always | Below 1 Ω |
| E35-31 (SGND) - L12-2 | Always | Below 1 Ω |
| E35-17 (RHTR) - E35-31 (SGND) | Always | 10 kΩ or higher |
| E35-17 (RHTR) or L12-1 - Body ground | Always | 10 kΩ or higher |
| E35-31 (SGND) or L12-2 - Body ground | Always | 10 kΩ or higher |
OK
NG