The combination meter assembly receives the turn signal switch information and controls the turn signal lights.
When replacing the combination meter assembly, make sure to replace it with a new one.
Operate the GTS according to the display and select the Data List (See page Vehicle Exterior>LIGHTING (EXT)>LIGHTING SYSTEM>DATA LIST / ACTIVE TEST).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Turn Signal Switch (Right) | Turn signal switch (right) / ON or OFF | ON: Turn signal switch (right) on
OFF: Turn signal switch (right) off |
- |
| Turn Signal Switch (Left) | Turn signal switch (left) / ON or OFF | ON: Turn signal switch (left) on
OFF: Turn signal switch (left) off |
- |
| Result | Proceed to |
|---|---|
| Data List values are as specified | A |
| Data List values are not as specified | B |
A
B
Remove the headlight dimmer switch (See page Vehicle Exterior>LIGHTING (EXT)>HEADLIGHT DIMMER SWITCH>REMOVAL).
Inspect the headlight dimmer switch (See page Vehicle Exterior>LIGHTING (EXT)>HEADLIGHT DIMMER SWITCH>INSPECTION).
OK
NG
Disconnect the E14 switch connector.
Disconnect the E120 meter connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E14-15 (TL) - E120-10 (EL) | Always | Below 1 Ω |
| E14-13 (TR) - E120-9 (ER) | ||
| E14-12 (ET) - Body ground | ||
| E14-15 (TL) - Body ground | Always | 10 kΩ or higher |
| E14-13 (TR) - Body ground |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E14-11 (TL) - E120-10 (EL) | Always | Below 1 Ω |
| E14-12 (TR) - E120-9 (ER) | ||
| E14-15 (ET) - Body ground | ||
| E14-11 (TL) - Body ground | Always | 10 kΩ or higher |
| E14-12 (TR) - Body ground |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E14-18 (TL) - E120-10 (EL) | Always | Below 1 Ω |
| E14-16 (TR) - E120-9 (ER) | ||
| E14-19 (ET) - Body ground | ||
| E14-18 (TL) - Body ground | Always | 10 kΩ or higher |
| E14-16 (TR) - Body ground |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| E14-19 (TL) - E120-10 (EL) | Always | Below 1 Ω |
| E14-20 (TR) - E120-9 (ER) | ||
| E14-16 (ET) - Body ground | ||
| E14-19 (TL) - Body ground | Always | 10 kΩ or higher |
| E14-20 (TR) - Body ground |
OK
NG