The engine stop and start ECU uses the park/neutral position switch assembly installed to the automatic transmission assembly to detect when the shift lever is in P or N.
Refer to DTC P085012.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>P085012
Before replacing the engine stop and start ECU, read the number of starter operations, total number of engine starts and write it into a new engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
After replacing the engine stop and start ECU, perform learning of the external backup boost converter (eco run vehicle converter assembly).
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
After replacing the engine stop and start ECU or air conditioning amplifier assembly, reset and perform learning of the air conditioning information in the engine stop and start ECU.
Click hereEngine / Hybrid System>STOP AND START>STOP AND START SYSTEM>REGISTRATION
Inspect the fuses for circuits related to this system before performing the following procedure.
Enter the following menus: Powertrain / Stop and Start / Data List / Neutral Switch.
| Tester Display |
|---|
| Neutral Switch |
In accordance with the display on the GTS, read the Data List.
| Tester Display | Condition | Normal Condition |
|---|---|---|
| Neutral Switch | Shift lever in P or N | ON |
| Shift lever not in P or N | OFF |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereDrivetrain>AJA0F (AUTOMATIC TRANSMISSION / TRANSAXLE)>PARK / NEUTRAL POSITION SWITCH>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Click hereDrivetrain>AJA0F (AUTOMATIC TRANSMISSION / TRANSAXLE)>PARK / NEUTRAL POSITION SWITCH>REMOVAL
Disconnect the engine stop and start ECU connector.
Disconnect the park/neutral position switch assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
Click Location & Routing(B38,C34)Location & Routingewd_type=routing;type=c,c;code=B38,C34 Click Connector(B38)Instrument Panel>Engine Room Main Wire / Heater Blower Wire>Engine Stop and Start ECUewd_type=component;type=c;code=B38;pinno=21,17 |
||
| B38-21 (STA) - C34-5 (L) | Always | Below 1 Ω |
| B38-17 (CLL) - C34-4 (B) | Always | Below 1 Ω |
| B38-21 (STA) - Body ground | Always | 80 to 180 Ω |
| B38-17 (CLL) - Body ground | Always | 10 kΩ or higher |
| C34-5 (L) - Body ground | Always | 80 to 180 Ω |
| C34-4 (B) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG