| *A | for Integrated Type | *B | for Separate Type |
| *1 | NO. 2 IDLER PULLEY COVER PLATE | *2 | IDLER PULLEY COVER PLATE |
| *3 | GENERATOR BRACKET | *4 | ENGINE WIRE |
|
Tightening torque for "Major areas involving basic vehicle performance such as moving/turning/stopping" : N*m (kgf*cm, ft.*lbf) |
|
N*m (kgf*cm, ft.*lbf): Specified torque |
|
Do not apply lubricants to the threads parts | - | - |
27060 1.INSTALL GENERATOR ASSEMBLY
Install the generator bracket to the generator with the bolt.
Temporarily install the generator assembly with the 2 bolts.
Tighten the generator assembly with the 2 bolts in the order shown in the illustration.
Install the generator bracket with the bolt.
16604 2.INSTALL NO. 2 IDLER PULLEY SUB-ASSEMBLY
|
|
16361A 3.INSTALL FAN AND GENERATOR V BELT
53785B 4.INSTALL FRONT FENDER APRON TRIM PACKING D
5.INSTALL FRONT WHEEL
6.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
7. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART