The glow plug is mounted inside the engine combustion chamber. To ensure efficient engine starting with a cold engine, the ECM calculates a time interval of the current that needs to flow through the glow plug depending on the starting engine coolant temperature when the ignition switch is turned to ON. The ECM then turns on the glow plug relay and permits the current to flow through the glow plug based on the ECM's calculated time. The glow plug relay is then heated, and enhances fuel combustion with a cold engine.
This DTC will be set if the glow plug or the circuit is open.
These troubleshooting procedures are for: 1) difficult engine starting in cold weather, and 2) difficulty driving / vehicle malfunctions in cold weather immediately after engine is started.
After the engine is started, the ECM performs an "after-glow" for a certain period of time. In proportion to the actual engine coolant temperature, the time period varies. The after-glow reduces diesel engine knocking, white smoke emissions and engine noises when the engine is cold.
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
After replacing the ECM, the new ECM needs registration (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ DPF)>REGISTRATION) and initialization (See page Engine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ DPF)>INITIALIZATION).
| *1 | Engine Room Relay Block Assembly |
| *2 | GLOW 1 |
| *3 | GLOW 2 |
Remove the GLOW1 and GLOW2 relays from the engine room relay block assembly.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| GLOW 1 relay holder 2 - Body ground | Ignition switch ON | 11 to 14 V |
| GLOW 2 relay holder 2 - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Inspect the glow relay.
Click hereEngine / Hybrid System>1VD-FTV (STARTING)>RELAY>ON-VEHICLE INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *1 | Screw Grommet |
Disconnect the glow plug connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Glow plug terminal - Body ground | 20°C (68°F) | Approximately 1 Ω |
If any of the glow plugs has an open circuit, the engine power will be insufficient only when the engine is cold.
Exercise extreme care not to damage the glow plug pipes. Damaging them could cause an open circuit, or shorten the life of the glow plugs.
Keep the glow plugs free of oil and fuel while cleaning.
Wipe any oil off of the terminal and Bakelite washer with a clean, dry cloth during inspection.
Do not apply more than 11 V to the glow plugs as it may cause an open circuit.
Reconnect the glow plug connector.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check the glow plug installation.
Click hereEngine / Hybrid System>1VD-FTV (STARTING)>GLOW PLUG>INSTALLATION
Glow plugs are installed securely.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the GLOW1 and GLOW2 relays from the engine room relay block assembly.
Disconnect the glow plug connectors.
Disconnect the cable from the negative (-) battery terminal.
Disconnect the cable from the positive (+) battery terminal.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| GLOW 1 relay terminal 3 - C45-1 | Always | Below 1 Ω |
| GLOW 1 relay terminal 5 - Positive (+) battery terminal cable | Always | Below 1 Ω |
| GLOW 1 relay terminal 2 - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| GLOW 2 relay terminal 3 - C62-1 | Always | Below 1 Ω |
| GLOW 2 relay terminal 5 - Positive (+) battery terminal cable | Always | Below 1 Ω |
| GLOW 2 relay terminal 2 - Body ground | Always | Below 1 Ω |
| Proceed to |
| OK |
| NG |
OK
Click hereEngine / Hybrid System>1VD-FTV (ENGINE CONTROL)>ECD SYSTEM (w/ DPF)>CHECK FOR INTERMITTENT PROBLEMS
NG
Remove the GLOW1 and GLOW2 relays from the engine room R/B assembly.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| GLOW 1 relay terminal 2 - A29-12 (GREL) | Always | Below 1 Ω |
| GLOW 2 relay terminal 2 - A29-23 (GRL2) | Always | Below 1 Ω |
| GLOW 1 relay terminal 2 or A29-12 (GREL) - Body ground | Always | 10 kΩ or higher |
| GLOW 2 relay terminal 2 or A29-23 (GRL2) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
| OK |
| NG |
OK
NG