The motor relay and motor fail-safe relay are built into the brake actuator assembly.
During ABS, TRC, VSC, or brake assist operation, the skid control ECU (brake actuator assembly) turns on the motor relay to run the pump motor in the brake actuator assembly.
When a motor system DTC is stored, the motor fail-safe relay cuts the power source supply to the motor relay for fail-safe operation.
These DTCs may be stored when the voltage to the motor relay power source (BM terminal) is lower than the DTC detection condition due to low output from the battery or alternator.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| C052C13 | ABS Pump Motor Control Circuit Open | Either of the following is detected:
·
When the +BS terminal voltage is from 9.5 to 17.4 V with the motor relay ON while control operates, a relay contact OFF condition continues for 0.12 seconds or more.
·
When the +BS terminal voltage is from 9.5 to 17.4 V, a motor relay supervision voltage malfunction continues for 0.12 seconds or more when the motor relay turns ON during control operation. |
·
Motor relay (Brake actuator assembly)
·
Wire harness or connector |
| C052C49 | ABS Pump Motor Control Internal Electronic Failure | Any of the following is detected:
·
When the +BS terminal voltage is from 9.5 to 17.4 V, overcurrent in the motor relay and motor fail-safe relay continues for 0.05 seconds or more.
·
When the +BS terminal voltage is from 9.5 to 17.4 V, a motor relay gate voltage malfunction continues for 0.12 seconds or more.
·
Motor relay overcurrent continues for 0.05 seconds or more. |
·
Motor relay (Brake actuator assembly)
·
Wire harness or connector |
| C052F14 | ABS Pump Motor Supply Voltage Circuit Short to Ground or Open | When voltage at +BS terminal is 9.5 V or higher, open in BM terminal continues for 1 second or more. |
·
Skid Control ECU (Brake actuator assembly)
·
Wire harness or connector |
| Vehicle Condition | |||
|---|---|---|---|
| Pattern 1 | Pattern 2 | ||
| Diagnosis Condition | When the +BS terminal voltage is from 9.5 to 17.4 V | ○ | ○ |
| Malfunction Status | Motor relay ON while control operates, relay contact OFF condition continues | ○ | - |
| Motor relay supervision voltage malfunction continues, motor relay turns ON during control operation | - | ○ | |
| Detection Time | 0.12 seconds or more. | 0.12 seconds or more. | |
| Number of Trips | 1 trip | 1 trip | |
DTC will be output when conditions for either of the patterns in the table above are met.
| Vehicle Condition | ||||
|---|---|---|---|---|
| Pattern 1 | Pattern 2 | Pattern 3 | ||
| Diagnosis Condition | When the +BS terminal voltage is from 9.5 to 17.4 V | ○ | ○ | - |
| Malfunction Status | Overcurrent in motor relay and motor fail-safe relay continues | ○ | - | - |
| Motor relay gate voltage malfunction continues | - | ○ | - | |
| Motor relay overcurrent continues | - | - | ○ | |
| Detection Time | 0.05 seconds or more. | 0.12 seconds or more. | 0.05 seconds or more. | |
| Number of Trips | 1 trip | 1 trip | 1 trip | |
DTC will be output when conditions for either of the patterns in the table above are met.
After replacing the skid control ECU (brake actuator assembly), perform "Calibration".
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
When C137BA2 and/or C137BA3 is output together with C052C13, C052C49 and/or C052F14 inspect and repair the trouble areas indicated by C137BA2 and/or C137BA3 first.
for C137BA2: Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>VEHICLE STABILITY CONTROL SYSTEM (w/ Pre-collision System)>C137BA2
for C137BA3: Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>VEHICLE STABILITY CONTROL SYSTEM (w/ Pre-collision System)>C137BA3
| *a | Front view of wire harness connector (to Skid Control ECU [Brake Actuator Assembly]) |
Turn the ignition switch off.
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
Disconnect the A45 skid control ECU (brake actuator assembly) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A45-46 (BM) - Body ground | Always | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
| *a | Front view of wire harness connector (to Skid Control ECU [Brake Actuator Assembly]) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A45-30 (GND2) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
These codes are stored when a problem is identified in the skid control ECU (brake actuator assembly). The motor relay is in the skid control ECU (brake actuator assembly). Therefore, motor relay inspections and motor relay unit inspections cannot be performed. Be sure to check if any DTCs are output before replacing the brake actuator assembly.
Reconnect the A45 skid control ECU (brake actuator assembly) connector.
Clear the DTCs.
Turn the ignition switch off.
Start the engine.
Drive the vehicle at a speed of 20 km/h (12 mph) or more for 30 seconds or more.
Check if the same DTC is recorded.
| Result | Proceed to |
|---|---|
| DTCs C052C13, C052C49 and C052F14 are not output | A |
| DTCs C052C13, C052C49 and/or C052F14 are output | B |
If a speed signal of 20 km/h (12 mph) or more is input to the skid control ECU (brake actuator assembly), with the ignition switch ON and the stop light switch off, the ECU performs self diagnosis of the motor and solenoid circuits.
If the normal system code is output (the trouble code is not output), slightly jiggle the connectors, wire harness, and fuses of the skid control ECU (brake actuator assembly). Make sure that no DTCs are output.
If any DTCs are output while jiggling a connector or wire harness from the skid control ECU (brake actuator assembly), inspect and repair the connector or wire harness.
The DTCs were probably output due to a bad connection of the connector terminal.
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B