The shift control ECU sends SBFS (fail-safe) signals to the EV control ECU.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P176A87 | Lost Communication with Fail Safe Signal (Gear Shift Control Module "A") Missing Message | The SBFS (fail-safe) signals sent from the shift control ECU cannot be received by the EV control ECU continuously for 2 seconds or more.
(1 trip detection logic) |
·
Shift control ECU ·
EV control ECU ·
Wire harness or connector |
·
Master Warning -
Comes on ·
Multi-information Display Error Message -
Displayed |
EV | A |
After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the All Readiness check procedure.
Click hereDrivetrain>Q710 (HYBRID TRANSMISSION / TRANSAXLE)>ELECTRONIC SHIFT LEVER SYSTEM>UTILITY
Turn the ignition switch to ON (READY) and wait for 2 minutes or more.
The vehicle is equipped with a shift control supply. Therefore, ensure there is no power being supplied to the vehicle when disconnecting or reconnecting the connector of the shift control ECU and when removing or installing the shift control ECU.
Click hereDrivetrain>Q710 (HYBRID TRANSMISSION / TRANSAXLE)>ELECTRONIC SHIFT LEVER SYSTEM>PRECAUTION
| Result | Proceed to |
|---|---|
| for LHD | A |
| for RHD | B |
A
B
Pre-procedure1
| *a | Front view of wire harness connector
(to EV Control ECU) |
| *b | Waveform (Fail-safe signal) |
Disconnect the EV control ECU connector.
Procedure1
Connect an oscilloscope between the EV control ECU connector terminals specified in the table below.
Turn the ignition switch to ON and measure the waveform.
| Tester Connection | Condition | Equipment Setting |
|---|---|---|
|
Click Location & Routing(A8,A17)Location & Routingewd_type=routing;type=c,c;code=A8,A17 Click Connector(A8)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A8;pinno=10 Click Connector(A17)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A17;pinno=4 |
||
| A8-10 (SBFS) - A17-4 (E1) | Ignition switch ON | 10 V/DIV., 20 ms./DIV. |
Turning the ignition switch to ON with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
The waveforms differ when the shift control ECU is malfunctioning.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the EV control ECU connector.
OK
NG
Pre-procedure1
Disconnect the D92 shift control ECU connector.
Disconnect the A8 EV control ECU connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A8,D92)Location & Routingewd_type=routing;type=c,c;code=A8,D92 Click Connector(A8)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A8;pinno=10 Click Connector(D92)Instrument Panel>Instrument Panel Wire>Shift Control ECUewd_type=component;type=c;code=D92;pinno=3 |
||
| A8-10 (SBFS) - D92-3 (SBFS) | Always | Below 1 Ω |
| A8-10 (SBFS) or D92-3 (SBFS) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the A8 EV control ECU connector.
Reconnect the D92 shift control ECU connector.
OK
NG
Pre-procedure1
| *a | Front view of wire harness connector
(to EV Control ECU) |
| *b | Waveform (Fail-safe signal) |
Disconnect the EV control ECU connector.
Procedure1
Connect an oscilloscope between the EV control ECU connector terminals specified in the table below.
Turn the ignition switch to ON and measure the waveform.
| Tester Connection | Condition | Equipment Setting |
|---|---|---|
|
Click Location & Routing(D15,A17)Location & Routingewd_type=routing;type=c,c;code=D15,A17 Click Connector(D15)Instrument Panel>Instrument Panel Wire>EV Control ECUewd_type=component;type=c;code=D15;pinno=10 Click Connector(A17)Instrument Panel>Front Compartment Main Wire>EV Control ECUewd_type=component;type=c;code=A17;pinno=4 |
||
| D15-10 (SBFS) - A17-4 (E1) | Ignition switch ON | 10 V/DIV., 20 ms./DIV. |
Turning the ignition switch to ON with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
The waveforms differ when the shift control ECU is malfunctioning.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Reconnect the EV control ECU connector.
OK
NG
Pre-procedure1
Disconnect the D92 shift control ECU connector.
Disconnect the D15 EV control ECU connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D15,D92)Location & Routingewd_type=routing;type=c,c;code=D15,D92 Click Connector(D15)Instrument Panel>Instrument Panel Wire>EV Control ECUewd_type=component;type=c;code=D15;pinno=10 Click Connector(D92)Instrument Panel>Instrument Panel Wire>Shift Control ECUewd_type=component;type=c;code=D92;pinno=3 |
||
| D15-10 (SBFS) - D92-3 (SBFS) | Always | Below 1 Ω |
| D15-10 (SBFS) or D92-3 (SBFS) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the D15 EV control ECU connector.
Reconnect the D92 shift control ECU connector.
OK
NG