The battery cooling blower assembly speed is controlled by the battery ECU assembly. The power source of the battery cooling blower assembly is supplied by turning the IGCT No. 2 relay and BATT FAN relay ON by the MREL terminal of the EV control ECU. The battery ECU assembly sends command signals (SI0) to the battery cooling blower assembly to adjust the fan speed to an appropriate speed for the EV battery temperature. The frequency (FP0) of the battery cooling blower assembly is sent to the battery ECU assembly as a monitor signal.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P0A8111 | Hybrid/EV Battery Cooling Fan 1 Circuit Short to Ground | Both of the following conditions are met:
·
The speed calculated based on the battery cooling blower assembly output frequency is not within the target control speed range. ·
The battery cooling blower assembly speed is excessively low when a certain level of speed is requested (possibility of an open or short to ground in connected circuits, or motor locking). (2 trip detection logic) |
·
Battery cooling blower assembly ·
Battery ECU assembly ·
BATT FAN fuse ·
Wire harness or connector |
Master Warning:
Comes on |
EV Battery | A |
| P0A814B | Hybrid/EV Battery Cooling Fan 1 Over Temperature | Both of the following conditions are met:
·
The EV battery temperature is high and the speed calculated based on the battery cooling blower assembly output frequency is not within the target control speed range. ·
The EV battery temperature is high and the battery cooling blower assembly speed is excessively low when a certain level of speed is requested (possibility of an open or short to ground in connected circuits, or motor locking). (1 trip detection logic) |
·
Battery cooling blower assembly ·
Battery ECU assembly ·
BATT FAN fuse ·
Wire harness or connector |
Master Warning:
Comes on |
EV Battery | A |
| DTC No. | Data List |
|---|---|
| P0A8111 | ·
Hybrid/EV Battery Cooling Fan 1 Drive Request ·
Hybrid/EV Battery Cooling Fan 1 Drive Status ·
Hybrid/EV Battery Cooling Fan 1 Frequency |
| P0A814B |
The following items can be helpful when performing repairs:
Hybrid/EV Battery Temperature 1 to 6
BATT Voltage
"Hybrid/EV Battery Cooling Fan 1 Frequency" is detected when the battery cooling blower assembly is operating and its value changes in proportion to the battery cooling blower assembly speed.
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 10 minutes or more.
Enter the following menus: Powertrain / EV Battery / Active Test / Control the Hybrid/EV Battery Cooling Fan.
Select fan mode 1 and operate the battery cooling blower assembly and wait for 60 seconds or more.
Operation of the battery cooling blower assembly can be confirmed by checking if air is sucked into the air intake port of the intake duct.
Enter the following menus: Powertrain / EV Battery / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
As the battery cooling blower assembly speed is excessively low, there is a possibility of an open or short to ground in connected circuits, or motor locking.
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P0A8111 or P0A814B for Hybrid battery system is output | A |
| P0A8111 or P0A814B is output and DTCs other than the DTCs in the table below are output | B |
| P0A8111 or P0A814B is output and Hybrid battery system DTCs in the table below are output | C |
| P0A8111 or P0A814B is output and Hybrid control system DTCs in the table below are output | D |
| System | Relevant DTC | |
|---|---|---|
| Hybrid battery system | P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure |
| P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | |
| Hybrid control system | P0A1F94 | Hybrid/EV Battery Energy Control Module Unexpected Operation |
Post-procedure1
Turn the ignition switch off.
A
B
C
D
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Pre-procedure1
Clear the DTCs and freeze frame data.
Procedure1
Select air volume mode 6 in the "Control the Hybrid/EV Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
| Tester Display | Measurement Item | Control Range | Restrict Condition |
|---|---|---|---|
| Control the Hybrid/EV Battery Cooling Fan | Battery cooling blower assembly operation and blower volume can be checked. | OFF, 1, 2, 3, 4, 5, 6 | Intake air temperature -10°C (14°F) or higher |
| Tester Display |
|---|
| Control the Hybrid/EV Battery Cooling Fan |
If the Active Test cannot be performed, skip it and proceed to the next step to check if the fan operates and air is sucked. In accordance with fail-safe system operation, the battery ECU assembly sends a command to operate the battery cooling blower assembly.
Check that the battery cooling blower assembly operates, air is sucked into the inlet duct and the operation sound is normal.
The battery cooling blower assembly may not stop even when turning the cooling fan off in the "Control the Hybrid/EV Battery Cooling Fan" Active Test. This is due to HV system control and is not a malfunction.
The battery cooling blower assembly operates.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the center No. 2 floor to brace extension.
Disconnect the G156 No. 2 EV battery pack wire connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Disconnect the G31 battery cooling blower assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Procedure1
| *a | Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector) |
| *b | Front view of wire harness connector
(to Battery Cooling Blower Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G156,G31)Location & Routingewd_type=routing;type=c,c;code=G156,G31 Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assemblyewd_type=component;type=c;code=G156;pinno=12 Click Connector(G31)Body>Floor Wire / No. 3 Floor Wire>Battery Cooling Blower Assemblyewd_type=component;type=c;code=G31;pinno=2 |
||
| G156-12 (FP0) - G31-2 (FP0) | Ignition switch off | Below 1 Ω |
| G156-12 (FP0) or G31-2 (FP0) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G156,G31)Location & Routingewd_type=routing;type=c,c;code=G156,G31 Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assemblyewd_type=component;type=c;code=G156;pinno=12 Click Connector(G31)Body>Floor Wire / No. 3 Floor Wire>Battery Cooling Blower Assemblyewd_type=component;type=c;code=G31;pinno=2 |
||
| G156-12 (FP0) - G31-2 (FP0) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the service plug grip and FC converter power outlet cable removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the G31 battery cooling blower assembly connector.
Reconnect the G156 No. 2 EV battery pack wire connector.
Install the center No. 2 floor to brace extension.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the center No. 2 floor to brace extension.
Connect the cable to the negative (-) auxiliary battery terminal.
Clear the DTCs and freeze frame data.
Procedure1
Select each air volume mode (1 to 6) in the "Control the Hybrid/EV Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
| Tester Display | Measurement Item | Control Range | Restrict Condition |
|---|---|---|---|
| Control the Hybrid/EV Battery Cooling Fan | Battery cooling blower assembly operation and blower volume can be checked. | OFF, 1, 2, 3, 4, 5, 6 | Intake air temperature -10°C (14°F) or higher |
| Active Test Display |
|---|
| Control the Hybrid/EV Battery Cooling Fan |
| Data List Display |
|---|
| Hybrid/EV Battery Cooling Fan 1 Frequency |
If the Active Test cannot turn off the battery cooling blower assembly, skip it and proceed to the next step to check the frequency value. In accordance with fail-safe system operation, the battery ECU assembly sends a command to operate the battery cooling fan assembly.
| *a | Component with harness connected
(No. 2 EV Battery Pack Wire Connector) |
While the cooling fan is operating, compare the value in the Data List (Hybrid/EV Battery Cooling Fan 1 Frequency) with the frequency value that was actually measured at the battery ECU assembly connector.
| Tester Connection | Condition |
|---|---|
|
Click Location & Routing(G156)Location & Routingewd_type=routing;type=c;code=G156 Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assemblyewd_type=component;type=c;code=G156;pinno=12,1 |
|
| G156-12 (FP0) - G156-1 (GND) | Battery cooling blower assembly is operating. |
Turning the ignition switch to ON with the service plug grip and FC converter power outlet cable removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Compare the values in each air volume mode (1 to 6). If the Active Test cannot be performed, compare the values only in the current air volume mode.
| Result | Proceed to |
|---|---|
| Both of the value in the Data List (Hybrid/EV Battery Cooling Fan 1 Frequency) and the actual measured value at the battery ECU assembly connector are 0 Hz. | A |
| Other than above | B |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the center No. 2 floor to brace extension.
A
B
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the center No. 2 floor to brace extension.
Disconnect the G31 battery cooling blower assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Procedure1
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G31)Location & Routingewd_type=routing;type=c;code=G31 Click Connector(G31)Body>Floor Wire / No. 3 Floor Wire>Battery Cooling Blower Assemblyewd_type=component;type=c;code=G31;pinno=2,4 |
||
| G31-2 (FP0) - G31-4 (GND0) | Ignition switch ON | 4.5 to 5.5 V |
Turning the ignition switch to ON with the service plug grip and FC converter power outlet cable removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the G31 battery cooling blower assembly connector.
Install the center No. 2 floor to brace extension.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No.1 EV battery cover sub-assembly.
Disconnect the z26 battery ECU assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Procedure1
| *a | Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector) |
| *b | Rear view of wire harness connector
(to Battery ECU Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G156,z26)Location & Routingewd_type=routing;type=c,c;code=G156,z26 Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assemblyewd_type=component;type=c;code=G156;pinno=12 Click Connector(z26)Body>other>EV Supply Battery Assembly , Battery ECU Assemblyewd_type=component;type=c;code=z26;pinno=32 |
||
| G156-12 (FP0) - z26-32 (FP0) | Always | Below 1 Ω |
| G156-12 (FP0) or z26-32 (FP0) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the z26 battery ECU assembly connector.
Install the upper No.1 EV battery cover sub-assembly.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the center No. 2 floor to brace extension.
Connect the cable to the negative (-) auxiliary battery terminal.
Clear the DTCs and freeze frame data.
Procedure1
Select each air volume mode (1 to 6) in the "Control the Hybrid/EV Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
| Tester Display | Measurement Item | Control Range | Restrict Condition |
|---|---|---|---|
| Control the Hybrid/EV Battery Cooling Fan | Battery cooling blower assembly operation and blower volume can be checked. | OFF, 1, 2, 3, 4, 5, 6 | Intake air temperature -10°C (14°F) or higher |
| Active Test Display |
|---|
| Control the Hybrid/EV Battery Cooling Fan |
| Data List Display |
|---|
| Hybrid/EV Battery Cooling Fan 1 Frequency |
If the Active Test cannot turn off the battery cooling blower assembly, skip it and proceed to the next step to check the frequency value. In accordance with fail-safe system operation, the battery ECU assembly sends a command to operate the battery cooling blower assembly.
| *a | Component with harness connected
(No. 2 EV Battery Pack Wire Connector) |
While the cooling fan is operating, compare the value in the Data List (Hybrid/EV Battery Cooling Fan 1 Frequency) with the frequency value that was actually measured at the battery ECU assembly connector.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G156)Location & Routingewd_type=routing;type=c;code=G156 Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assemblyewd_type=component;type=c;code=G156;pinno=12,1 |
||
| G156-12 (FP0) - G156-1 (GND) | Battery cooling blower assembly is operating. | Difference between the value in the Data List (Hybrid/EV Battery Cooling Fan 1 Frequency) and the actual measured value at the battery ECU assembly connector is 10% or less. |
Turning the ignition switch to ON with the service plug grip and FC converter power outlet cable removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Compare the values in each air volume mode (1 to 6). If the Active Test cannot be performed, compare the values only in the current air volume mode.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the center No. 2 floor to brace extension.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 1 EV battery cover sub-assembly.
Disconnect the z26 battery ECU assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Procedure1
| *a | Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector) |
| *b | Rear view of wire harness connector
(to Battery ECU Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G156,z26)Location & Routingewd_type=routing;type=c,c;code=G156,z26 Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assemblyewd_type=component;type=c;code=G156;pinno=12 Click Connector(z26)Body>other>EV Supply Battery Assembly , Battery ECU Assemblyewd_type=component;type=c;code=z26;pinno=32 |
||
| G156-12 (FP0) - z26-32 (FP0) | Always | Below 1 Ω |
| G156-12 (FP0) or z26-32 (FP0) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the z26 battery ECU assembly connector.
Install the upper No. 1 EV battery cover sub-assembly.
OK
NG
Pre-procedure1
| *1 | Luggage Room Relay Block Assembly |
| *a | BATT FAN Fuse |
Remove the BATT FAN fuse from the luggage room relay block assembly.
Procedure1
Measure the resistance of the BATT FAN fuse.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| BATT FAN fuse terminals 1 - 2 | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the BATT FAN fuse to the luggage room relay block assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the center No. 2 floor to brace extension.
Disconnect the G31 battery cooling blower assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Connect the cable to the negative (-) auxiliary battery terminal.
Clear the DTCs and freeze frame data.
Procedure1
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G31)Location & Routingewd_type=routing;type=c;code=G31 Click Connector(G31)Body>Floor Wire / No. 3 Floor Wire>Battery Cooling Blower Assemblyewd_type=component;type=c;code=G31;pinno=1,4 |
||
| G31-1 (IG0) - G31-4 (GND0) | Ignition switch ON | 11 to 14 V |
Turning the ignition switch to ON with the service plug grip and FC converter power outlet cable removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turning the ignition switch to ON with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
As there might be an intermittent malfunction, inspect the following items even if the measured voltage is as specified.
Installation condition of fuse(s) (before removing fuse(s)) (IG circuit)
Fuse condition (before and after removing fuse(s)) (IG circuit)
Connection condition of connectors (IG circuit)
Wire harness condition (IG circuit)
Wire harness condition (GND circuit)
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the G31 battery cooling blower assembly connector.
Install the center No. 2 floor to brace extension.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the center No. 2 floor to brace extension.
Disconnect the G156 No. 2 EV battery pack wire connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Disconnect the G31 battery cooling blower assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Check the terminals of the connector for deformation and corrosion.
Procedure1
| *a | Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector) |
| *b | Front view of wire harness connector
(to Battery Cooling Blower Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G156,G31)Location & Routingewd_type=routing;type=c,c;code=G156,G31 Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assemblyewd_type=component;type=c;code=G156;pinno=3 Click Connector(G31)Body>Floor Wire / No. 3 Floor Wire>Battery Cooling Blower Assemblyewd_type=component;type=c;code=G31;pinno=3 |
||
| G156-3 (SI0) - G31-3 (SI0) | Ignition switch off | Below 1 Ω |
| G156-3 (SI0) or G31-3 (SI0) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G156,G31)Location & Routingewd_type=routing;type=c,c;code=G156,G31 Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assemblyewd_type=component;type=c;code=G156;pinno=3 Click Connector(G31)Body>Floor Wire / No. 3 Floor Wire>Battery Cooling Blower Assemblyewd_type=component;type=c;code=G31;pinno=3 |
||
| G156-3 (SI0) or G31-3 (SI0) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the service plug grip and FC converter power outlet cable removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
If the ignition switch is turned to ON with the connectors disconnected, other DTCs will be stored. Be sure to clear the DTCs after the inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the G31 battery cooling blower assembly connector.
Reconnect the G156 No. 2 EV battery pack wire connector.
Install the center No. 2 floor to brace extension.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the center No. 2 floor to brace extension.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Procedure1
| *a | Component with harness connected
(No. 2 EV Battery Pack Wire Connector) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G156)Location & Routingewd_type=routing;type=c;code=G156 Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assemblyewd_type=component;type=c;code=G156;pinno=3,1 |
||
| G156-3 (SI0) - G156-1 (GND) | Ignition switch ON | 4.5 to 5.5 V |
Turning the ignition switch to ON with the service plug grip and FC converter power outlet cable removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the center No. 2 floor to brace extension.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the center No. 2 floor to brace extension.
Connect the cable to the negative (-) auxiliary battery terminal.
Clear the DTCs and freeze frame data.
Procedure1
Select each air volume mode (1 to 6) in the "Control the Hybrid/EV Battery Cooling Fan" Active Test to operate the battery cooling blower assembly.
| Tester Display | Measurement Item | Control Range | Restrict Condition |
|---|---|---|---|
| Control the Hybrid/EV Battery Cooling Fan | Battery cooling blower assembly operation and blower volume | OFF, 1, 2, 3, 4, 5, 6 | Intake air temperature -10°C (14°F) or higher |
| Tester Display |
|---|
| Control the Hybrid/EV Battery Cooling Fan |
If the Active Test cannot turn off the battery cooling blower assembly, skip it and proceed to the next step to check the waveform. In accordance with fail-safe system operation, the battery ECU assembly sends a command to operate the battery cooling blower assembly.
| *a | Component with harness connected
(No. 2 EV Battery Pack Wire Connector) |
| *a | Waveform 1 |
Connect an oscilloscope to the G156 No. 2 EV battery pack wire connector and check the waveform.
| Item | Content |
|---|---|
| Tester Connection | G156-3 (SI0) - G156-1 (GND) |
| Equipment Setting | 10 V/DIV., 1 ms./DIV. |
| Condition | Ignition switch ON, during Active Test |
Turning the ignition switch to ON with the service plug grip and FC converter power outlet cable removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Perform this inspection with the No. 2 EV battery pack wire connector connected.
The wave length will vary with the operating speed of the battery cooling blower assembly.
| Result | Proceed to |
|---|---|
| Normal (The pulse output of waveform 1) | A |
| No pulse generation | B |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Install the center No. 2 floor to brace extension.
A
B
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 1 EV battery cover sub-assembly.
Disconnect the z26 battery ECU assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Procedure1
| *a | Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector) |
| *b | Rear view of wire harness connector
(to Battery ECU Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G156,z26)Location & Routingewd_type=routing;type=c,c;code=G156,z26 Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assemblyewd_type=component;type=c;code=G156;pinno=3 Click Connector(z26)Body>other>EV Supply Battery Assembly , Battery ECU Assemblyewd_type=component;type=c;code=z26;pinno=33 |
||
| G156-3 (SI0) - z26-33 (SI0) | Always | Below 1 Ω |
| G156-3 (SI0) or z26-33 (SI0) - Body ground and other terminals | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the z26 battery ECU assembly connector.
Install the upper No. 1 EV battery cover sub-assembly.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Remove the upper No. 1 EV battery cover sub-assembly.
Disconnect the z26 battery ECU assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Procedure1
| *a | Component without harness connected
(Battery ECU Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z26)Location & Routingewd_type=routing;type=c;code=z26 Click Connector(z26)Body>other>EV Supply Battery Assembly , Battery ECU Assemblyewd_type=component;type=c;code=z26;pinno=33,11,31 |
||
| z26-33 (SI0) - z26-11 (GND) | Always | 10 kΩ or higher |
| z26-33 (SI0) - z26-31 (GND1) | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the z26 battery ECU assembly connector.
Install the upper No. 1 EV battery cover sub-assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the center No. 2 floor to brace extension.
Disconnect the G31 battery cooling blower assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Procedure1
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G31)Location & Routingewd_type=routing;type=c;code=G31 Click Connector(G31)Body>Floor Wire / No. 3 Floor Wire>Battery Cooling Blower Assemblyewd_type=component;type=c;code=G31;pinno=4 |
||
| G31-4 (GND0) - Body ground | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Connect the G31 battery cooling blower assembly connector.
Install the center No. 2 floor to brace extension.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the center No. 2 floor to brace extension.
Disconnect the G156 No. 2 EV battery pack wire connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Procedure1
| *a | Front view of wire harness connector
(No. 2 EV Battery Pack Wire Connector) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G156)Location & Routingewd_type=routing;type=c;code=G156 Click Connector(G156)Body>Floor Wire / No. 3 Floor Wire>EV Supply Battery Assemblyewd_type=component;type=c;code=G156;pinno=1,10 |
||
| G156-1 (GND) - Body ground | Ignition switch off | Below 1 Ω |
| G156-10 (GND1) - Body ground | Ignition switch off | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the G156 No. 2 EV battery pack wire connector.
Install the center No. 2 floor to brace extension.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the center No. 2 floor to brace extension.
Disconnect the G31 battery cooling blower assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Check that each connector between the BATT FAN relay and battery cooling blower assembly is not loose or disconnected.
Remove the BATT FAN relay from the luggage room relay block assembly.
Check the relay for deformation and corrosion.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *1 | Luggage Room Relay Block Assembly | - | - |
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly) |
*b | BATT FAN Relay Holder |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G31)Location & Routingewd_type=routing;type=c;code=G31 Click Connector(G31)Body>Floor Wire / No. 3 Floor Wire>Battery Cooling Blower Assemblyewd_type=component;type=c;code=G31;pinno=1 |
||
| G31-1 (IG0) - 5 (BATT FAN relay holder) | Ignition switch off | Below 1 Ω |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
Make sure that each connector between the battery cooling blower assembly and BATT FAN relay holder is not loose or disconnected and its terminals are not deformed or corroded.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the BATT FAN relay to the luggage room relay block assembly.
Reconnect the G31 battery cooling blower assembly connector.
Install the center No. 2 floor to brace extension.
OK
NG
Be sure to wear insulated gloves and protective goggles.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the upper No. 1 EV battery cover sub-assembly.
Disconnect the z26 battery ECU assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Procedure1
| *a | Rear view of wire harness connector
(to Battery ECU Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(z26)Location & Routingewd_type=routing;type=c;code=z26 Click Connector(z26)Body>other>EV Supply Battery Assembly , Battery ECU Assemblyewd_type=component;type=c;code=z26;pinno=11,31 |
||
| z26-11 (GND) - Body ground | Always | Below 1 Ω |
| z26-31 (GND1) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the z26 battery ECU assembly connector.
Install the upper No. 1 EV battery cover sub-assembly.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the center No. 2 floor to brace extension.
Disconnect the G31 battery cooling blower assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Remove the BATT FAN fuse from the luggage room relay block assembly.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *1 | Luggage Room Relay Block Assembly | - | - |
| *a | Front view of wire harness connector
(to Battery Cooling Blower Assembly) |
*b | BATT FAN Fuse Holder |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G31)Location & Routingewd_type=routing;type=c;code=G31 Click Connector(G31)Body>Floor Wire / No. 3 Floor Wire>Battery Cooling Blower Assemblyewd_type=component;type=c;code=G31;pinno=1 |
||
| G31-1 (IG0) - Terminals other than 2 (BATT FAN fuse holder) and body ground | Ignition switch off | 10 kΩ or higher |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the BATT FAN fuse to the luggage room relay block assembly.
Reconnect the G31 battery cooling blower assembly connector.
Install the center No. 2 floor to brace extension.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the center No. 2 floor to brace extension.
Disconnect the G31 battery cooling blower assembly connector.
Before disconnecting the connector, check that it is not loose or disconnected.
Procedure1
| *a | Component without harness connected
(Battery Cooling Blower Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(G31)Location & Routingewd_type=routing;type=c;code=G31 Click Connector(G31)Body>Floor Wire / No. 3 Floor Wire>Battery Cooling Blower Assemblyewd_type=component;type=c;code=G31;pinno=1,4 |
||
| G31-1 (IG0) - G31-4 (GND0) and Body ground | Always | 10 kΩ or higher |
When taking a measurement with a tester, do not apply excessive force to the tester probe to avoid damaging the holder.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the G31 battery cooling blower assembly connector.
Install the center No. 2 floor to brace extension.
OK
NG
| Proceed to |
|---|
| NEXT |
NEXT
| Proceed to |
|---|
| NEXT |
NEXT