Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › 2020.11–2021.08
RM37H0E _51 Engine / Hybrid System _096346 HYBRID / BATTERY CONTROL _0463852 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0AA749  Hybrid/EV Battery Voltage Isolation Sensor Circuit Internal Electronic Failure  


DESCRIPTION

The EV control ECU monitors the insulation monitoring circuit located in the battery ECU assembly and detects malfunctions.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P0AA749 Hybrid/EV Battery Voltage Isolation Sensor Circuit Internal Electronic Failure Malfunction in the insulation monitoring circuit in the battery ECU assembly
(1 trip detection logic)
·

Battery voltage sensor (for upper side)

·

Battery ECU assembly

·

Wire harness or connector


Master Warning:
Comes on
EV A

Related Data List
DTC No. Data List
P0AA749 Short Wave Highest Value Level

CONFIRMATION DRIVING PATTERN

HINT:

After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY


1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off and wait for 10 minutes or more.

3.

Turn the ignition switch to ON and wait for 70 seconds or more.

4.

Enter the following menus: Powertrain / EV / Utility / All Readiness.

5.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.

Make sure to remove the service plug grip first.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the EV supply battery assembly

-

Disconnecting the low voltage connector of the FC converter assembly


·
A484004

To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.

-

The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.

-

Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.


·
A484005C01
1.667,0.74 2.115,0.427 true 2.188,0.385 2.448,0.552 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.

If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.

·
A358020

After removing the EV supply battery assembly, keep it away from water. Exposure to water may cause the EV supply battery assembly to produce heat, resulting in a fire.



NOTICE:
·

After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART


·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



PROCEDURE

1.CLEAR DTC

Pre-procedure1

a.

None.


Procedure1

a.

Clear the DTCs and freeze frame data.

Powertrain > EV > Clear DTCs
50002 397
Result:
Proceed to
NEXT



Post-procedure1

a.

Turn the ignition switch off and wait for 10 minutes or more.



NEXT

2.SIMULATION TEST
2.SIMULATION TEST

Pre-procedure1

a.

Turn the ignition switch to ON and wait for 70 seconds or more.

NOTICE:

Do not turn the ignition switch off until step 3 is complete.



Procedure1

a.

Check if DTCs are output.

Powertrain > EV > Trouble Codes
50001 397
Result:
Result Proceed to
P0AA749 is not output A
P0AA749 is output B



Post-procedure1

a.

None.



A

3.SIMULATION TEST

B

4.CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - BATTERY VOLTAGE SENSOR (for Upper Side))
3.SIMULATION TEST
NOTICE:

Do not turn the ignition switch off while performing this inspection.


Pre-procedure1

a.

With the vehicle and engine stopped, turn the ignition switch to ON (READY) with park (P) selected and wait for 10 minutes or more. (If the engine starts, wait until the engine stops.)


b.

While depressing the brake pedal without depressing the accelerator pedal, move the shift lever to select shift state drive (D) and wait for 1 minute. (Step A)


c.

Drive the vehicle 0.5 m (1.6 ft.) forward and perform step A.


d.

Drive the vehicle another 0.5 m (1.6 ft.) forward and perform step A. Repeat this procedure 5 times (minimum total driving distance: 2 m (6.6 ft.)).


Procedure1

a.

Check if DTCs are output.

Powertrain > EV > Trouble Codes
50001 397
Result:
Result Proceed to
P0AA649 is not output A
P0AA649 is output B



Post-procedure1

a.

Turn the ignition switch off.



A

4.CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - BATTERY VOLTAGE SENSOR (for Upper Side))

B

4.CHECK HARNESS AND CONNECTOR (BATTERY ECU ASSEMBLY - BATTERY VOLTAGE SENSOR (for Upper Side))

OK

5.INSPECT BATTERY VOLTAGE SENSOR (for Upper Side)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.INSPECT BATTERY VOLTAGE SENSOR (for Upper Side)

OK

NG

REPLACE BATTERY VOLTAGE SENSOR (for Upper Side)