MALFUNCTION DESCRIPTION
The EV control ECU detects a VB sensor or VL sensor malfunction.
The cause of this malfunction may be one of the following:
Voltage sensor malfunction
Motor generator control ECU (MG ECU) malfunction
Communication (wire harness) malfunction
EV supply battery assembly malfunction
No. 1 EV battery junction block assembly malfunction
Inverter with converter assembly malfunction
High-voltage wire harness malfunction
High-voltage connector or connection malfunction
FC converter assembly malfunction
Inspection Overview
| Inspection Content | Reason (Narrow Down in Order Using Inspection Procedures Below) |
|---|---|
| Check for DTCs (EV) | Output DTCs |
| Check for DTCs (check voltage sensor malfunction locations)
Check for DTCs (drive test) |
Put vehicle in ready ON (vehicle stopped and being driven) and then check whether DTCs are output again. |
| Read value using GTS | Data List value |
| Check freeze frame data (EV) | FREEZE FRAME DATA |
| Read value using GTS | Accelerator and brake pedal simultaneously depressed Data List value |
Refer to the description for DTC P0CA300.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0CA300
The MG ECU uses a voltage sensor (VL) that is built into the boost converter to detect the high voltage before it is boosted. The ECU also uses the battery ECU assembly to detect EV battery voltage (VB).
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1C2D62 | Hybrid/EV Battery "A" Voltage Sensor/Boosting Converter Voltage Sensor "A" Signal Compare Failure | Voltages from EV battery voltage (VB) sensor and boost converter voltage (VL) sensor deviate:
Difference between "VL-Voltage before Boosting" and "Hybrid/EV Battery Voltage" is large when the boosting request is given. (1 trip detection logic) |
·
Inverter with converter assembly ·
Battery ECU assembly |
Master Warning:
Comes on |
EV | A |
| DTC No. | Data List |
|---|---|
| P1C2D62 | ·
Hybrid/EV Battery Voltage ·
VL-Voltage before Boosting ·
VH-Voltage after Boosting ·
Boost Ratio |
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
Turn the ignition switch off and wait for 10 minutes or more.
Turn the ignition switch to ON (READY).
Push the P position switch (shift position indicator) to select park (P), depress the accelerator pedal to raise the "Hybrid/EV Battery SOC" to a sufficient level.
Check that the FC system is stopped and move the shift lever to select shift state neutral (N).
Set the A/C for maximum cooling.
Leave the vehicle for a few minutes.
When the accelerator pedal is not depressed with the ignition switch ON (READY) and park (P) selected, if "VL-Voltage before Boosting" and the "Hybrid/EV Battery Voltage" is approximately the same after repair, the condition is judged as normal.
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
One of the following applies:
·
Only P1C2D62 is output. ·
One or more DTCs other than P0E311C, P0CA300, P0B231C, and DTCs in the table below are also output. |
A |
| P1C2D62 and P0E311C or P0CA300 are output at the same time. | B |
| P1C2D62 and P0B231C are output at the same time. | C |
| DTCs of hybrid control system in the tables below are output. | D |
| DTCs of hybrid battery system in the tables below are output. | E |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Microcomputer malfunction | Hybrid control system | P060647 | Hybrid/EV Powertrain Control Module Processor Watchdog / Safety MCU Failure |
| P0A1B49 | Drive Motor "A" Control Module Internal Electronic Failure | ||
| P1C8F47 | FC Air Compressor Motor Control Module Watchdog/Safety MCU Failure | ||
| P1D8F49 | FC Air Compressor Motor Control Module Internal Electronic Failure | ||
| P0A1B1F | Drive Motor "A" Control Module Circuit Intermittent | ||
| Hybrid battery system | P060B49 | Hybrid/EV Battery Energy Control Module A/D Processing Internal Electronic Failure | |
| P060687 | Hybrid/EV Battery Energy Control Module Processor to Monitoring Processor Missing Message | ||
| P060A47 | Hybrid/EV Battery Energy Control Module Monitoring Processor Watchdog / Safety MCU Failure | ||
| P060A87 | Hybrid/EV Battery Energy Control Module Processor from Monitoring Processor Missing Message | ||
| P060B16 | Hybrid/EV Battery Energy Control Module A/D Processing Circuit Voltage Below Threshold | ||
| P0E2D00 | Hybrid/EV Battery Energy Control Module Hybrid/EV Battery Monitor Performance | ||
| Power source circuit malfunction | Hybrid control system | P06D61C | Generator Control Module Offset Power Circuit Voltage Out of Range |
| P06E61C | Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range | ||
| Communication system malfunction | Hybrid control system | P312387 | Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
| U011187 | Lost Communication with Hybrid/EV Battery Energy Control Module "A" Missing Message | ||
| Sensor and actuator circuit malfunction | Hybrid battery system | P301A1C | Hybrid/EV Battery Stack 1 Cell Voltage Detection Voltage Out of Range |
| P1A001C | Hybrid/EV Battery Stack 2 Cell Voltage Detection Voltage Out of Range | ||
| P1AFD1C | Flying Capacitor/Internal Control Module Hybrid/EV Battery Monitor Voltage Out of Range | ||
| System malfunction | Hybrid control system | P0E3116 | DC/DC Converter Voltage Sensor "A" Circuit Voltage Below Threshold |
| P0E3117 | DC/DC Converter Voltage Sensor "A" Circuit Voltage Above Threshold | ||
P1C2D62 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
D
E
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P06881F
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
Apply the parking brake and secure the wheels using chocks.
Connect the GTS to the DLC3. *1
Turn the ignition switch to ON (READY). *2
Enter the following menus: Powertrain / EV / Data List. *3
| Tester Display |
|---|
| Hybrid/EV Battery SOC |
Push the P position switch (shift position indicator) to select park (P). *4
If the value of "Hybrid/EV Battery SOC" is less than 55%, charge the EV battery by depressing the accelerator pedal until the value reaches 55% or more. *5
Set the air conditioning to MAX COOL and turn the headlights on. *6
Confirm that "Hybrid/EV Battery Current" is more than 3 A. *7
| Tester Display |
|---|
| Hybrid/EV Battery Current |
With the FC system stopped and the conditions of steps *5, *6 and *7 satisfied, leave the vehicle for 15 seconds. *8
Enter the following menus: Powertrain / EV, EV battery / Trouble codes. *9
Procedure1
Check for DTCs. *10
If the low EV supply battery assembly information comes on, push the P position switch (shift position indicator) to select park (P) and start the engine to charge the EV supply battery assembly. After the engine stops, perform steps *1 through *10 again.
| Result | Proceed to |
|---|---|
| No DTCs are output, or DTCs except the following are output | A |
| P0E311C or P0CA300 are output | B |
| P0B231C or P1C8349 are output | C |
| P300000 is output | D |
| None of the above conditions are met | E |
Post-procedure1
Turn the ignition switch off.
A
B
C
D
E
Pre-procedure1
None.
Procedure1
Read the freeze frame data of DTC P1C2D62.
| Tester Display | Measurement Item | Range |
|---|---|---|
| VL-Voltage before Boosting | High voltage before it is boosted | - |
| Hybrid/EV Battery Voltage | EV supply battery voltage | Min.: 0.0 V, Max.: 510.0 V |
| Tester Display |
|---|
| VL-Voltage before Boosting |
| Hybrid/EV Battery Voltage |
| Result | Proceed to |
|---|---|
| Both of the following are satisfied or both of the following are not satisfied | A |
| The value of VL-Voltage before Boosting is more than 351 V, or less than 227 V | B |
| The value of Hybrid/EV Battery Voltage is more than 351 V, or less than 227 V | C |
Post-procedure1
Turn the ignition switch off.
A
B
C
Pre-procedure1
Apply the parking brake and secure the wheels using chocks.
Turn the ignition switch to ON (READY).
Procedure1
Push the P position switch (shift position indicator) to select park (P).
If the value of "Hybrid Battery SOC" is less than 55%, charge the EV supply battery assembly by depressing the accelerator pedal until the value reaches 55% or more.
| Tester Display |
|---|
| Hybrid/EV Battery SOC |
Release the accelerator pedal, and wait for the FC system to stop. Read the Data List when the FC system stops.
If the FC system starts, wait until it stops before continuing.
| Tester Display |
|---|
| Hybrid/EV Battery Voltage |
| Hybrid/EV Battery Cell 1 Voltage |
| Hybrid/EV Battery Cell 2 Voltage |
| Hybrid/EV Battery Cell 3 Voltage |
| Hybrid/EV Battery Cell 4 Voltage |
| Hybrid/EV Battery Cell 5 Voltage |
| Hybrid/EV Battery Cell 6 Voltage |
| Hybrid/EV Battery Cell 7 Voltage |
| Hybrid/EV Battery Cell 8 Voltage |
| Hybrid/EV Battery Cell 9 Voltage |
| Hybrid/EV Battery Cell 10 Voltage |
| Hybrid/EV Battery Cell 11 Voltage |
| Hybrid/EV Battery Cell 12 Voltage |
| Hybrid/EV Battery Cell 13 Voltage |
| Hybrid/EV Battery Cell 14 Voltage |
| Hybrid/EV Battery Cell 15 Voltage |
| Hybrid/EV Battery Cell 16 Voltage |
| Hybrid/EV Battery Cell 17 Voltage |
| Hybrid/EV Battery Cell 18 Voltage |
| Hybrid/EV Battery Cell 19 Voltage |
| Hybrid/EV Battery Cell 20 Voltage |
| Hybrid/EV Battery Cell 21 Voltage |
| Hybrid/EV Battery Cell 22 Voltage |
| Hybrid/EV Battery Cell 23 Voltage |
| Hybrid/EV Battery Cell 24 Voltage |
| Hybrid/EV Battery Cell 25 Voltage |
| Hybrid/EV Battery Cell 26 Voltage |
| Hybrid/EV Battery Cell 27 Voltage |
| Hybrid/EV Battery Cell 28 Voltage |
| Hybrid/EV Battery Cell 29 Voltage |
| Hybrid/EV Battery Cell 30 Voltage |
| Hybrid/EV Battery Cell 31 Voltage |
| Hybrid/EV Battery Cell 32 Voltage |
| Hybrid/EV Battery Cell 33 Voltage |
| Hybrid/EV Battery Cell 34 Voltage |
| Hybrid/EV Battery Cell 35 Voltage |
| Hybrid/EV Battery Cell 36 Voltage |
| Hybrid/EV Battery Cell 37 Voltage |
| Hybrid/EV Battery Cell 38 Voltage |
| Hybrid/EV Battery Cell 39 Voltage |
| Hybrid/EV Battery Cell 40 Voltage |
| Hybrid/EV Battery Cell 41 Voltage |
| Hybrid/EV Battery Cell 42 Voltage |
| Hybrid/EV Battery Cell 43 Voltage |
| Hybrid/EV Battery Cell 44 Voltage |
| Hybrid/EV Battery Cell 45 Voltage |
| Hybrid/EV Battery Cell 46 Voltage |
| Hybrid/EV Battery Cell 47 Voltage |
| Hybrid/EV Battery Cell 48 Voltage |
| Hybrid/EV Battery Cell 49 Voltage |
| Hybrid/EV Battery Cell 50 Voltage |
| Hybrid/EV Battery Cell 51 Voltage |
| Hybrid/EV Battery Cell 52 Voltage |
| Hybrid/EV Battery Cell 53 Voltage |
| Hybrid/EV Battery Cell 54 Voltage |
| Hybrid/EV Battery Cell 55 Voltage |
| Hybrid/EV Battery Cell 56 Voltage |
| Hybrid/EV Battery Cell 57 Voltage |
| Hybrid/EV Battery Cell 58 Voltage |
| Hybrid/EV Battery Cell 59 Voltage |
| Hybrid/EV Battery Cell 60 Voltage |
| Hybrid/EV Battery Cell 61 Voltage |
| Hybrid/EV Battery Cell 62 Voltage |
| Hybrid/EV Battery Cell 63 Voltage |
| Hybrid/EV Battery Cell 64 Voltage |
| Hybrid/EV Battery Cell 65 Voltage |
| Hybrid/EV Battery Cell 66 Voltage |
| Hybrid/EV Battery Cell 67 Voltage |
| Hybrid/EV Battery Cell 68 Voltage |
| Hybrid/EV Battery Cell 69 Voltage |
| Hybrid/EV Battery Cell 70 Voltage |
| Hybrid/EV Battery Cell 71 Voltage |
| Hybrid/EV Battery Cell 72 Voltage |
| Hybrid/EV Battery Cell 73 Voltage |
| Hybrid/EV Battery Cell 74 Voltage |
| Hybrid/EV Battery Cell 75 Voltage |
| Hybrid/EV Battery Cell 76 Voltage |
| Hybrid/EV Battery Cell 77 Voltage |
| Hybrid/EV Battery Cell 78 Voltage |
| Hybrid/EV Battery Cell 79 Voltage |
| Hybrid/EV Battery Cell 80 Voltage |
| Hybrid/EV Battery Cell 81 Voltage |
| Hybrid/EV Battery Cell 82 Voltage |
| Hybrid/EV Battery Cell 83 Voltage |
| Hybrid/EV Battery Cell 84 Voltage |
| Result | Proceed to |
|---|---|
| Both of the following are satisfied:
·
Sum of all "Hybrid/EV Battery Cell 1 to 84 Voltage" is more than ("Hybrid/EV Battery Voltage" -5 V) ·
Sum of all "Hybrid/EV Battery Cell 1 to 84 Voltage" is less than ("Hybrid/EV Battery Voltage" -5 V) |
A |
| The preceding condition is not satisfied. | B |
Post-procedure1
Turn the ignition switch off.
A
B