| *1 | NO. 1 HYDROGEN DETECTOR BRACKET | *2 | NO. 1 HYDROGEN TUBE |
| *3 | NO. 1 HYDROGEN SUPPLY TUBE SUB-ASSEMBLY | *4 | HYDROGEN SUPPLY PRIMARY PIPE SUB-ASSEMBLY |
| *5 | HYDROGEN SUPPLY SECONDARY PIPE SUB-ASSEMBLY | *6 | WIRE HARNESS |
| *7 | INSULATOR | - | - |
| ● | Non-reusable part | - | - |
1. CAUTIONS FOR COMPRESSED HYDROGEN GAS
2. PRESSURE RELEASE OPERATION (for Low Pressure and Medium Pressure)
1A906
3.REMOVE FC STACK COVER SUB-ASSEMBLY
1A911
4.REMOVE FC STACK COVER BRACKET
23A30
5.REMOVE HYDROGEN SUPPLY PRESSURE REGULATOR ASSEMBLY
|
Shift |
|
Pull Up |
Disconnect the 5 connectors and detach the 2 clamps.
Remove the bolt and disconnect the No. 1 hydrogen detector bracket.
Remove the 2 nuts and 2 bolts.
Remove the 3 bolts and hydrogen supply pressure regulator assembly from the No. 1 hydrogen tube and No. 1 hydrogen supply tube sub-assembly.
Remove the O-ring from the No. 1 hydrogen tube.
Remove the O-ring from the No. 1 hydrogen supply tube sub-assembly.
Protect the openings of the No. 1 hydrogen tube, No. 1 hydrogen supply tube sub-assembly and hydrogen supply pressure regulator assembly with protective tape (non-residue type) to prevent the entry of foreign matter or water.
6.REMOVE WIRE HARNESS CLAMP BRACKET
23250H
7.REMOVE FUEL INJECTOR ASSEMBLY
Remove the 2 bolts and hydrogen supply secondary pipe sub-assembly.
Protect the openings of the hydrogen primary pipe sub-assembly with protective tape (non-residue type) to prevent the entry of foreign matter or water.
Remove the 3 fuel injector assemblies from the hydrogen supply secondary pipe sub-assembly.
Protect the openings of the hydrogen secondary pipe sub-assembly with protective tape (non-residue type) to prevent the entry of foreign matter or water.
Remove the 3 O-rings and 3 insulators from the 3 fuel injector assemblies.