HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  Weak Blower Output  


DESCRIPTION

If the blower airflow volume is weak regardless of the air conditioning control assembly being normal, the following causes are possible.

Symptom Factor
·

Blower airflow volume is continuously weak

·

Blower airflow volume is sometimes weak


·

Customize setting

·

Communication malfunction between air conditioning amplifier assembly and blower with fan motor sub-assembly

·

Air conditioning amplifier assembly malfunction

·

Blower with fan motor sub-assembly malfunction

·

Clean air filter is clogging

·

Evaporator or heater core fin clogging

·

No. 1 cooler thermistor malfunction

·

Aspirator dropped



PROCEDURE

1.CHECK BLOWER FAN OPERATION
a.

Prepare the vehicle according to the table below. with the manual mode.

Blower Switch Condition
LO → HI
·

Temperature setting: Max COOL

·

Mode switch: FACE

·

A/C Switch: OFF



OK:

Airflow volume is changed.



Result:
Proceed to
OK
NG



OK

2.CHECK ECO DRIVE MODE OPERATION

NG

2.CHECK ECO DRIVE MODE OPERATION
a.

Confirm setup of the ECO drive mode and turn it off if it becomes ON.

HINT:
·

When ECO drive mode is on, the air conditioning amplifier assembly ensures a minimum level of air conditioning control based on certain conditions, thereby contributing to improved fuel efficiency. Accordingly, explain to customers that the air volume will be weaker in these situations.

Control
Airflow Control Automatically switches the air inlet port to the internal air circulation mode when the outside air temperature is equal to or higher than a predetermined temperature and reduces the power consumption.
Air Inlet Control Sets the blower level in AUTO mode lower than normal, and suppresses the power consumption.




Result:
Proceed to
NEXT



NEXT

3.CHECK CLEAN AIR FILTER
3.CHECK CLEAN AIR FILTER
a.

Check the clean air filter by the visually confirm.

OK:

The clean air filter is not dirty or clogging.



Result:
Proceed to
OK
NG



OK

4.CHECK NO. 1 COOLER THERMISTOR

NG

4.CHECK NO. 1 COOLER THERMISTOR
a.

Check the installation condition of the No. 1 cooler thermistor.

OK:

No. 1 cooler thermistor is installed correctly.



Result:
Proceed to
OK
NG



OK

5.CHECK ASPIRATOR

NG

5.CHECK ASPIRATOR
a.

Check the installation condition of the aspirator.

OK:

Aspirator is installed correctly.



Result:
Proceed to
OK
NG



OK

REPLACE HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR (HEATER RADIATOR UNIT SUB-ASSEMBLY OR NO. 1 COOLER EVAPORATOR WAS CLOGGING)

NG