If the fresh/recirculation mode does not change or exhaust gas can be smelled even while set to recirculation mode, the following causes are possible.
| Symptom | Factor |
|---|---|
·
Fresh/recirculation mode does not change ·
Fresh/recirculation mode does not change automatically |
·
Blower servo motor malfunction ·
Damper and link operation (jamming) ·
Blower assembly ·
High FC stack outlet coolant temperature |
Check for No. 1 blower damper servo sub-assembly is installed correctly.
No. 1 blower damper servo sub-assembly is installed correctly.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Check for DTCs.
DTC B1442 is not output
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| FC Stack Outlet Coolant Temperature (Filtered Value) | FC stack outlet coolant temperature | -40°C (-40°F) to 215.9 °C (421 °F) | 50 to 85 °C (122 to 185 °F): After warming up | - |
| Tester Display |
|---|
| FC Stack Outlet Coolant Temperature (Filtered Value) |
The value of the display does not change frequently.
| Proceed to |
|---|
| OK |
| NG |
OK
NG