HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting)  


DESCRIPTION

If there is a difference in temperature between the left and right air outlet while dual mode is ON, the following causes are possible.

Symptom Factor
There is a difference in temperature between the left and right air outlet (while cooling operation)
·

Compressor with motor assembly malfunction

·

Quantity of refrigerant gas lack

·

A/M servo motor

·

Damper and link operation (jamming)

·

Automatic light control sensor malfunction


There is a difference in temperature between the left and right air outlet (while heater operation)
·

Water with motor pump assembly malfunction

·

Damper and link operation (jamming)

·

Heater core closed waterway



WIRING DIAGRAM

E366622E23
0.229,1.021 1.802,1.396 1.573,0.375 10 false Air Conditioning Amplifier Assembly 1.844,3.865 3.208,4.021 1.365,0.156 10 false D13 1.854,4.021 4.073,4.219 2.219,0.198 10 false Automatic Light Control Sensor 4.646,3.969 6.01,4.125 1.365,0.156 10 false D11 4.646,4.125 6.833,4.552 2.188,0.427 10 false Main Body ECU (Multiplex Network Body ECU) 1.021,4.479 3.24,4.677 2.219,0.198 10 false : CAN Communication Line 4.594,1.646 5.052,1.823 0.458,0.177 10 false 23 4.885,1.646 5.344,1.823 0.458,0.177 10 false CLTB 4.594,2.427 5.052,2.604 0.458,0.177 10 false 24 4.906,2.427 5.365,2.604 0.458,0.177 10 false CLTS 4.615,3.094 5.073,3.271 0.458,0.177 10 false 25 4.906,3.083 5.365,3.26 0.458,0.177 10 false CLTE 3.115,1.646 3.573,1.823 0.458,0.177 10 false CLTB 3.625,1.656 4.083,1.833 0.458,0.177 10 false 1 3.125,2.438 3.583,2.615 0.458,0.177 10 false CLTS 3.615,2.427 4.073,2.604 0.458,0.177 10 false 4 3.615,3.104 4.073,3.281 0.458,0.177 10 false 2 3.125,3.115 3.583,3.292 0.458,0.177 10 false CLTE

CAUTION / NOTICE / HINT

NOTICE:
·

If DTC B1244 is output, troubleshoot for DTC B1244 first.

Click hereVehicle Exterior>LIGHTING (EXT)>LIGHTING SYSTEM>B1244

·

Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin.



PROCEDURE

1.CHECK MALFUNCTION STATUS
Result:
Result Proceed to
While cooling A
While heater B



A

2.CHECK REFRIGERANT SHORTAGE

B

6.PERFORM AIR OMISSION OF COOLANT
2.CHECK REFRIGERANT SHORTAGE
a.

Prepare the vehicle according to the table below.

Measurement Condition:
Item Condition
A/C switch On
Ambient temperature*1 0 to 49°C (32 to 120°F)
Air conditioning inlet temperature*2 25 to 49°C (77 to 120°F)
Setting temperature MAX COLD
Blower damper position Recirculation
Outlet damper position FACE
Blower speed HI

*1: If the ambient temperature is not within the range shown, do not perform this check.

*2: The air inlet temperature can be judged correctly only if it is within an appropriate range of 25 to 79°C (77 to 174°F). Therefore, use the heater mode to adjust the temperature so that it falls within the appropriate range and then perform the check.



b.

Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 121 3186
Result:
Result Amount of Refrigerant
Refrigerant shortage Insufficient or leakage
Refrigerant correct Correct


OK:

"Refrigerant correct" is displayed on GTS.



Result:
Proceed to
OK
NG



OK

3.PERFORM ACTIVE TEST USING GTS (SERVO PULSE)

NG

3.PERFORM ACTIVE TEST USING GTS (SERVO PULSE)
a.

Check the operation by referring to the table below.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Restrict Condition
Air Mix Servo Targ Pulse(D)
for LHD:

No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) operation


for RHD:

No. 1 air conditioning radiator damper servo sub-assembly (driver side lower air mix) operation


Min.: 128
Max.: 383
for LHD (for Dual):

Operates between 154 to 258 pulses


for LHD (for 3 Zone):

Operates between 254 to 358 pulses


for RHD:

Operates between 154 to 258 pulses


Air Mix Servo Targ Pulse(P)
for LHD:

No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) operation


for RHD:

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) operation


Min.: 128
Max.: 383
for LHD:

Operates between 154 to 258 pulses


for RHD (for Dual):

Operates between 154 to 258 pulses


for RHD (for 3 Zone):

Operates between 254 to 358 pulses


Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(P)
50004 121 25
OK:

Damper servo motor is operated.



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (AUTOMATIC LIGHT CONTROL SENSOR - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))

NG

GO TO DTC OF APPLICABLE SERVO MOTOR OPERATING ABNORMALLY

4.CHECK HARNESS AND CONNECTOR (AUTOMATIC LIGHT CONTROL SENSOR - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
a.

Disconnect the D13 automatic light control sensor connector.


b.

Disconnect the D11 main body ECU (multiplex network body ECU) connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(D13,D11)Location & Routing

Click Connector(D13)Instrument Panel>Instrument Panel Wire>Automatic Light Control Sensor

Click Connector(D11)Instrument Panel>Instrument Panel Wire>Main Body ECU

D13-1 (CLTB) - D11-23 (CLTB) Always Below 1 Ω
D13-2 (CLTE) - D11-25 (CLTE) Always Below 1 Ω
D13-4 (CLTS) - D11-24 (CLTS) Always Below 1 Ω
D13-1 (CLTB) or D11-23 (CLTB) - Other terminals and body ground Always 10 kΩ or higher
D13-2 (CLTE) or D11-25 (CLTE) - Other terminals and body ground Always 10 kΩ or higher
D13-4 (CLTS) or D11-24 (CLTS) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

5.INSPECT AUTOMATIC LIGHT CONTROL SENSOR

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.INSPECT AUTOMATIC LIGHT CONTROL SENSOR

OK

NG

REPLACE AUTOMATIC LIGHT CONTROL SENSOR

6.PERFORM AIR OMISSION OF COOLANT

Click hereEngine / Hybrid System>COOLING>COOLANT>REPLACEMENT

Result:
Proceed to
NEXT



NEXT

7.CHECK OPERATION (AIR CONDITIONING SYSTEM)
7.CHECK OPERATION (AIR CONDITIONING SYSTEM)
a.

Check that there is not a difference in temperature between the left and right air outlet.

OK:

There is not a difference in temperature between the left and right air outlet.



Result:
Proceed to
OK
NG



OK

END (FAILURE DUE TO AIR ENTERING COOLANT)

NG

8.PERFORM ACTIVE TEST USING GTS (SERVO PULSE)
8.PERFORM ACTIVE TEST USING GTS (SERVO PULSE)
a.

Check the operation by referring to the table below.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Restrict Condition
Air Mix Servo Targ Pulse(D)
for LHD:

No. 2 air conditioning radiator damper servo sub-assembly (driver side lower air mix) operation


for RHD:

No. 4 air conditioning radiator damper servo sub-assembly (driver side lower air mix) operation


Min.: 128
Max.: 383
for LHD (for Dual):

Operates between 154 to 258 pulses


for LHD (for 3 Zone):

Operates between 254 to 358 pulses


for RHD:

Operates between 154 to 258 pulses


Air Mix Servo Targ Pulse(P)
for LHD:

No. 4 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) operation


for RHD:

No. 2 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) operation


Min.: 128
Max.: 383
for LHD:

Operates between 154 to 258 pulses


for RHD (for Dual):

Operates between 154 to 258 pulses


for RHD (for 3 Zone):

Operates between 254 to 358 pulses


Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(P)
50004 121 25
OK:

Damper servo motor is operated.



Result:
Proceed to
OK
NG



OK

9.INSPECT WATER WITH MOTOR PUMP ASSEMBLY

NG

GO TO DTC OF APPLICABLE SERVO MOTOR OPERATING ABNORMALLY

9.INSPECT WATER WITH MOTOR PUMP ASSEMBLY
a.

Replace the water with motor pump assembly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>HEATER WATER PUMP>REMOVAL


b.

Check that there is not a difference in temperature between the left and right air outlets.

OK:

There is not a difference in temperature between the left and right air outlets.



Result:
Proceed to
OK
NG



OK

NG

REPLACE WATER WITH MOTOR PUMP ASSEMBLY