The hydrogen system of the FC system feeds the FC stack with compressed hydrogen, so that the FC stack can generate power. The low-range pressure circuit is located after the hydrogen injectors, and pressure applied to the circuit is regulated by the hydrogen injectors to an appropriate level for FC stack power generation.
If the regulated low-range hydrogen pressure (applied to the area after the hydrogen injectors) decreases below a threshold, the EV control ECU interprets it as a lower pressure limit error, and stores this DTC.
| *1 | Hydrogen Inlet Receptacle Assembly | *2 | Hydrogen Tank Pressure Sensor (for Inlet Side) |
| *3 | Hydrogen Tank Pressure Sensor (for Outlet Side) | *4 | No. 1 Hydrogen Tank Assembly |
| *5 | No. 2 Hydrogen Tank Assembly | *6 | No. 3 Hydrogen Tank Assembly |
| *7 | Hydrogen Tank Temperature Sensor 1 | *8 | Hydrogen Tank Temperature Sensor 2 |
| *9 | Hydrogen Tank Temperature Sensor 3 | *10 | Tank Shut Valve 1 |
| *11 | Tank Shut Valve 2 | *12 | Tank Shut Valve 3 |
| *13 | Hydrogen Supply Regulator Assembly | *14 | Hydrogen Primary Pressure Sensor |
| *15 | Fuel Injector Assembly | *16 | Hydrogen Secondary Pressure Sensor |
| *17 | FC Stack | *18 | Hydrogen Recirculation Pump Assembly |
| *19 | Exhaust Drainage Valve (Hydrogen Recirculation Separator Assembly) | *20 | FC Air Pressure Regulator Assembly (Air Pressure Regulating Valve) |
| *21 | FC Air Pressure Regulator Assembly (Air Sealing Valve) | *22 | FC Air By-pass Valve Assembly (Air Shunt Valve) |
| *23 | Pressure Relief Valve | *24 | Manual Valve |
| *25 | Pressure Relief Device | - | - |
| *a | Hydrogen System | *b | Air System |
| *c | From the FC Air Compressor Assembly | *d | To the Exhaust Drainage Pipe |
| *e | Low-range Pressure Circuit | - | - |
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1DC000 | Low-Range Hydrogen Pressure Too Low | When the low-range hydrogen pressure has decreased below the low-pressure limit or continuously does not meet the pressure regulation target valve, a malfunction is detected. Judgment is performed when the FC Mode is in FC Working or FC Shutdown Process
(1 trip detection logic) |
·
High-range hydrogen pressure pipe ·
Medium-range hydrogen pressure pipe ·
Hydrogen supply regulator assembly ·
Exhaust drainage valve ·
Fuel injector assembly ·
Hydrogen secondary pressure sensor ·
Low-range hydrogen pressure pipe ·
FC stack assembly |
Master Warning: Comes on | EV | B |
| Vehicle Condition | FC shutdown
(ignition switch ON) |
FC startup process | FC intermittent operation | FC is generating power
(vehicle is in stationary) |
FC is generating power
(vehicle is traveling) |
FC shutdown process |
|---|---|---|---|---|---|---|
| Data List
"FC Work Mode" |
Stop | Startup | Working | Finishing | ||
| Data List
"FC Intermittent Operation" |
OFF | ON | OFF | OFF | ||
| DTC Detection | - | - | ○ | ○ | ○ | ○ |
By accessing the "FC Work Mode" in the freeze frame data, the FC system condition at the time the malfunction occurred can be checked.
| DTC No. | Data List |
|---|---|
| P1DC000 | ·
Target Low-Range Hydrogen Pressure ·
Low-Range Hydrogen Pressure (Filtered Value) ·
Tank Shut Valve 1 Drive Status ·
Tank Shut Valve 2 Drive Status ·
Tank Shut Valve 3 Drive Status ·
Hydrogen Injector 1 Injection Period ·
Hydrogen Injector 2 Injection Period ·
Hydrogen Injector 3 Injection Period ·
High-Range Hydrogen Pressure (Filtered Value) ·
Medium-Range Hydrogen Pressure (Filtered Value) ·
Motor Room Hydrogen Density ·
Tank Area 1 Hydrogen Density ·
Tank Area 2 Hydrogen Density ·
Exhaust Drainage Valve ·
FC Work Mode |
| DTC No. | Active Test |
|---|---|
| P1DC000 | Control the Select Hydrogen Injector |
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Click hereEngine / Hybrid System>FUEL>FUEL SYSTEM>PRECAUTION
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Forcing the SOC of the EV supply battery assembly to decrease by applying electrical loads such as turning on the air conditioning (HOT MAX, maximum airflow), or depressing the accelerator pedal with the shift state in park (P), the "FC Intermittent Operation" of the Data List is easily to enter OFF (power generation mode).
After completion of repair, check that no hydrogen leaks from the hydrogen system components with a hydrogen gas detector.
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working.
Then, wait 2 minutes or more. Check that the "Low-Range Hydrogen Pressure (Filtered Value)" in the Data List is between "an atmospheric pressure plus 10 kPa" and "280 kPa(abs)".
The freeze frame data is cleared when DTCs are cleared. Be sure to make a note of necessary data in advance.
Pre-procedure1
None
Procedure1
According to the display on the GTS, check for DTCs in the Health Check.
| Result | Proceed to |
|---|---|
| Only P1DC000 is output | A |
| P1DC000 is output and DTCs other than the DTCs in the table below are output | B |
| P1DC000 is output and any DTCs in the table below are output | C |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Sensor and actuator circuit malfunction | P1D9A1C (FC) | Hydrogen Injector 1 Circuit Voltage Out of Range |
| P1DA01C (FC) | Hydrogen Injector 2 Circuit Voltage Out of Range | |
| P1DA51C (FC) | Hydrogen Injector 3 Circuit Voltage Out of Range | |
| P1DAA12 (FC) | Exhaust Drainage Valve Circuit Low | |
| P1DAA14 (FC) | Exhaust Drainage Valve Circuit Short to Battery | |
| P1DBA11 (FC) | Exhaust Drainage Valve Circuit Short to Ground or Open | |
| P1DBA15 (FC) | Low-Range Hydrogen Pressure Sensor Circuit Short to Battery or Open | |
| System malfunction | P1E427A (EV) | Hydrogen Leak (Excessive Hydrogen Flow) Fluid Leak or Seal Failure |
| P1E437A (EV) | Hydrogen Leak (High/Medium Pressure Area) Fluid Leak or Seal Failure | |
| P1E447A (EV) | Hydrogen Leak (Low Pressure Area) Fluid Leak or Seal Failure | |
P1DC000 may be store due to problems that cause the DTCs shown above to be output. If such happens, troubleshoot the suspected area(s) corresponding to the output DTC(s) in order of the listed DTCs shown in the table above.
Post-procedure1
Turn the ignition switch off.
A
B
C
Check for FC coolant leaks and the FC stack coolant level in the FC radiator reserve tank.
Pre-procedure1
Turn the ignition switch ON.
Procedure1
Turn the ignition switch to ON (READY) while checking the "FC Work Mode".
| Tester Display |
|---|
| FC Work Mode |
| Result | Proceed to |
|---|---|
| "FC Work Mode" switches to "Working" | A |
| "FC Work Mode" is "Stop" without switching to "Working" | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
Remove the under cover.
Check the hydrogen high-pressure piping from the hydrogen tank tube joint to the hydrogen supply regulator assembly for deformation or damage.
The hydrogen high-pressure piping is not deformed or damaged
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Pre-procedure1
Turn the ignition switch to ON (READY).
Procedure1
Read the value displayed on the GTS.
| Tester Display |
|---|
| High-Range Hydrogen Pressure (Filtered Value) |
| Result | Proceed to |
|---|---|
| The value of High-Range Hydrogen Pressure (Filtered Value) is less than 5000 kPa(abs) | A |
| None of the above conditions are met | B |
Post-procedure1
Turn the ignition switch off.
A
B
Fill the tank until the "High-Range Hydrogen Pressure (Filtered Value)" in the Data List exceeds 5000 kPa(abs).
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
Turn the ignition switch to ON (READY).
Procedure1
Read the value displayed on the GTS.
| Tester Display |
|---|
| Medium-Range Hydrogen Pressure (Filtered Value) |
| Result | Proceed to |
|---|---|
| The value of Medium-Range Hydrogen Pressure (Filtered Value) is 1100 kPa(abs) or less | A |
| None of the above conditions are met | B |
Post-procedure1
Turn the ignition switch off.
A
B
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Perform Leak Check (Low Pressure Point Leak Check) in the Utility menu.
| Tester Display |
|---|
| Leak Check |
While performing the Low Pressure Point Leak Check, check the "Low-Range Hydrogen Pressure (Filtered Value)" and "Target Low-Range Hydrogen Pressure" displayed on the GTS.
While performing the Low Pressure Point Leak Check, measure the hydrogen concentration around the FC stack and at the tailpipe with a hydrogen gas detector.
| Result | Proceed to |
|---|---|
| The hydrogen concentration around the FC stack is 300 ppm or more | A |
| The "Low-Range Hydrogen Pressure (Filtered Value)" displayed on the GTS is below the "Target Low-Range Hydrogen Pressure" | B |
| The hydrogen concentration at the tailpipe is 30000 ppm or more (If the measurement range of the hydrogen gas detector is insufficient, the hydrogen concentration reaches 90% of the upper limit of the measurement range within 5 seconds of starting a measurement) | C |
| The hydrogen concentration at the tailpipe is below 30000 ppm (If the measurement range of the hydrogen gas detector is insufficient, the hydrogen concentration does not reach 90% of the upper limit of the measurement range within 5 seconds of starting a measurement) | D |
A
B
C
D
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Perform Leak Check (Low Pressure Point Leak Check) in the Utility menu.
| Tester Display |
|---|
| Leak Check |
Apply soapy water to locate hydrogen leaking areas.
Do not apply soapy water to the FC stack assembly. If a hydrogen gas detector identifies gas leaks from the FC stack assembly, replace the FC stack assembly with new one.
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None
Procedure1
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working and "FC Intermittent Operation" is OFF.
| Active Test Display |
|---|
| Control the Select Hydrogen Injector |
| Data List Display |
|---|
| FC Work Mode |
| FC Intermittent Operation |
| Hydrogen Injector 1 Injection Period |
| Hydrogen Injector 2 Injection Period |
| Hydrogen Injector 3 Injection Period |
| Medium-Range Hydrogen Pressure (Filtered Value) |
| Low-Range Hydrogen Pressure (Filtered Value) |
While performing the "Control the Select Hydrogen Injector" Active Test, check "Medium-Range Hydrogen Pressure (Filtered Value)" and "Low-Range Hydrogen Pressure (Filtered Value)" in the Data List.
If the Active Test cannot be performed, check "Low-Range Hydrogen Pressure (Filtered Value)" and "Medium-Range Hydrogen Pressure (Filtered Value)" when either "Hydrogen Injector 1 Injection Period", "Hydrogen Injector 2 Injection Period" or "Hydrogen Injector 3 Injection Period" in the Data List when started is a value other than 0 μs.
If either "Hydrogen Injector 1 Injection Period", "Hydrogen Injector 2 Injection Period" or "Hydrogen Injector 3 Injection Period" shows a value other than 0 μs, an injection command is being sent to the injector.
| Result | Proceed to |
|---|---|
| For each hydrogen injector, their "Low-Range Hydrogen Pressure (Filtered Value)s" in the Data List increase by more than 5 kPa per injection.
(During normal operation) |
A |
| "Medium-Range Hydrogen Pressure (Filtered Value)" in the Data List decreases 100 kPa or more per injection for each hydrogen injector*1 | B |
| "Low-Range Hydrogen Pressure (Filtered Value)" in the Data List changes significantly over the target value during 1 injection by each of the hydrogen injectors*2 | C |
| Pressure does not change when each of the hydrogen injectors is performing injection, or any of the hydrogen injectors is not performing injection*3 | D |
*1: The decrease in "Medium-Range Hydrogen Pressure (Filtered Value)" may be due to insufficient supply caused by a malfunction in the hydrogen supply regulator assembly.
*2: When there is a blockage in the low pressure hydrogen pipes, "Low-Range Hydrogen Pressure (Filtered Value)" increases significantly when the hydrogen injector is performing injection, and decreases rapidly when the hydrogen injector stops injection.
*3: The hydrogen injector is malfunctioning.
*3: As to the change in pressure caused by the hydrogen injector's injection, be sure to check it in all of the hydrogen injectors.
*3: If all hydrogen injectors are malfunctioning, replace the hydrogen supply pressure regulator assembly.
Post-procedure1
None
A
B
C
D
If all hydrogen injectors are malfunctioning, replace the hydrogen supply pressure regulator assembly
Work procedures must be performed in an area with good ventilation (airflow) where hydrogen gas will not accumulate, and flames or other things that could act as ignition sources must not be present.
Accumulated hydrogen gas could ignite, resulting in a serious accident.
Pre-procedure1
Ensure the safety of the areas in front and at the back of the vehicle.
Put wheel chocks and securely apply the parking brake.
Procedure1
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working, "FC Intermittent Operation" is OFF, and "Exhaust Drainage Valve" is Close.
| Active Test Display |
|---|
| Activate the Exhaust Drainage Valve |
| Data List Display |
|---|
| FC Work Mode |
| FC Intermittent Operation |
| Exhaust Drainage Valve |
| *1 | Tailpipe |
| *2 | Hydrogen Gas Detector Probe |
Use the hydrogen gas detector to measure and record the hydrogen concentration in gas released from the tailpipe when the exhaust drainage valve is closed.
Perform this measurement in an environment where there is no wind.
Position the hydrogen gas detector probe in an area 100 mm (3.94 in.) away from the tailpipe opening. (Avoid locations underneath the tailpipe opening)
Position the hydrogen gas detector probe so that it is free from dropping water that comes from the tailpipe opening.
Perform the "Activate the Exhaust Drainage Valve" Active Test several times over 1 minute, and then, starting from the third test, use the hydrogen gas detector to measure the hydrogen concentration in gas released from the tailpipe when the exhaust drainage valve is open.
The exhaust drainage valve will open for 1 second each time the Active Test is performed, so measure the hydrogen concentration for several seconds.
Hydrogen concentration may not increase while coolant escapes when the valve is first opened. Therefore, start measuring from the third test.
There is a delayed response when performing detection using the hydrogen gas detector, so measure for several seconds.
"FC Intermittent Operation" in the Data List will be more likely to turn OFF if the accelerator pedal is depressed with the shift state in park (P).
| Result | Proceed to |
|---|---|
| The hydrogen concentration of the hydrogen gas detector will increase when "Exhaust Drainage Valve" in the Data List is Open rather than when "Exhaust Drainage Valve" is Close. | A |
| Other than above* | B |
*: The exhaust drainage valve is malfunctioning
Exhaust drainage valve is stuck closed:
Regardless of the "Exhaust Drainage Valve Driving Request" being ON or OFF, the concentration shown on the hydrogen gas detector has remained low.
Exhaust drainage valve is stuck open:
Regardless of the "Exhaust Drainage Valve Driving Request" being ON or OFF, the concentration shown on the hydrogen gas detector has remained high when the ignition switch is on (READY).
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None
Procedure1
Turn the ignition switch to ON (READY) with the shift state in park (P), and check that the Data List "FC Work Mode" is Working. Then, wait 2 minutes or more.
| Tester Display |
|---|
| FC Work Mode |
| Low-Range Hydrogen Pressure (Filtered Value) |
Read the "Low-Range Hydrogen Pressure (Filtered Value)" of the Data List.
Check for DTCs.
| Result | Proceed to |
|---|---|
| "Low-Range Hydrogen Pressure (Filtered Value)" of the Data List is more than an atmospheric pressure plus 10 kPa, and DTC P1DC000 is not output. | A |
| Other than above | B |
Post-procedure1
Turn the ignition switch off.
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B
Pre-procedure1
Remove the hydrogen secondary pressure sensor (low-range hydrogen pressure sensor).
Reconnect the hydrogen secondary pressure sensor (low-range hydrogen pressure sensor) connector.
Read the value displayed on the GTS.
| Tester Display |
|---|
| Low-Range Hydrogen Pressure (Filtered Value) |
Procedure1
Using the table, read the normal atmospheric pressure value for the applicable altitude.
| *a | Altitude, Temperature and Atmospheric Pressure Correlation Table | *b | Altitude (m (ft.)) |
| *c | Temperature (°C (°F)) | *d | Atmospheric Pressure (kPa (psi)) |
Standard atmospheric pressure is approximately 101 kPa (15 psi).
For every 100 m (328 ft.) increase in altitude, atmospheric pressure drops by approximately 1 kPa (0.1 psi). This varies by weather.
Compare the "Low-Range Hydrogen Pressure (Filtered Value)" values in the Data List with the normal atmospheric value from the table.
| Result | Proceed to |
|---|---|
| Difference between "Low-Range Hydrogen Pressure (Filtered Value)" in Data List and normal atmospheric pressure value is 35 kPa or more. | A |
| Other than above. | B |
Post-procedure1
Turn the ignition switch off.
A
B
Check the hydrogen low-pressure piping for deformation or damage.
The hydrogen low-pressure piping is not deformed or damaged
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the hydrogen low-pressure piping and check for blockage in the filter, etc. as well as internal deformation or damage.
There is no blockage in filter, etc., and no internal deformation or damage
| Proceed to |
|---|
| OK |
| NG |
OK
NG