Output values of any phase reactor current sensors, located inside the FC converter assembly, is smaller than the lower limit of the electric current value estimated from the FC voltage.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P1DDA00 | FC Converter Phase U Performance | Electric current value detected by the FC converter current sensor (phase U reactor current sensor) is smaller than the lower limit of the electric current value estimated from the FC voltage and the gate signal.
(1 trip detection logic) |
·
FC converter assembly ·
FC stack assembly |
Master Warning: Comes on | FCDC | B |
| P1DDB00 | FC Converter Phase V Performance | Electric current value detected by the FC converter current sensor (phase V reactor current sensor) is smaller than the lower limit of the electric current value estimated from the FC voltage and the gate signal.
(1 trip detection logic) |
·
FC converter assembly ·
FC stack assembly |
Master Warning: Comes on | FCDC | B |
| P1DDC00 | FC Converter Phase W Performance | Electric current value detected by the FC converter current sensor (phase W reactor current sensor) is smaller than the lower limit of the electric current value estimated from the FC voltage and the gate signal.
(1 trip detection logic) |
·
FC converter assembly ·
FC stack assembly |
Master Warning: Comes on | FCDC | B |
| P1DDD00 | FC Converter Phase X Performance | Electric current value detected by the FC converter current sensor (phase X reactor current sensor) is smaller than the lower limit of the electric current value estimated from the FC voltage and the gate signal.
(1 trip detection logic) |
·
FC converter assembly ·
FC stack assembly |
Master Warning: Comes on | FCDC | B |
| DTC No. | Data List |
|---|---|
| P1DDA00 | ·
FC Converter Output Voltage ·
Phase U Duty ·
Phase U Current |
| P1DDB00 | ·
FC Converter Output Voltage ·
Phase V Duty ·
Phase V Current |
| P1DDC00 | ·
FC Converter Output Voltage ·
Phase W Duty ·
Phase W Current |
| P1DDD00 | ·
FC Converter Output Voltage ·
Phase X Duty ·
Phase X Current |
Refer to the wiring diagram for the high-voltage circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA649
Refer to the wiring diagram for the FC relay circuit.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>P1E9011
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side.
Make sure to remove the EV supply battery assembly service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
After removing the service plug grip from the EV supply battery assembly, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system. After removing the FC converter power outlet cable (inverter with converter assembly) on FC converter side and use the "HIGH-VOLTAGE, DO NOT TOUCH" sign to notify other technicians that you are working on the high-voltage system.
After removal of the EV supply battery assembly service plug grip and FC converter power outlet cable (inverter with converter assembly) on FC converter side, wait for at least 10 minutes before touching the high-voltage connectors and terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
At least 10 minutes are necessary to discharge the high-voltage capacitors inside the inverter with converter assembly and FC stack assembly.
Since high voltage accumulates within the FC stack assembly with FC converter, never perform the work of separating the FC stack assembly with FC converter into the FC converter assembly and FC stack assembly without first performing electrical charge discharge (forced electrical charge discharge or electrical charge self-discharge), because doing so is dangerous.
Click hereEngine / Hybrid System>FC CONTROL>FC STACK>REMOVAL
Removing and installing the FC stack assembly without first discharging the electrical charge may result in an electric shock due to the high voltage circuit.
When reinstalling the service plug grip to the EV supply battery assembly, after lowering the EV supply battery assembly service plug grip 90°, securely slide it until a "click" sound is heard.
Click hereEngine / Hybrid System>FC CONTROL>FC CONTROL SYSTEM>PRECAUTION
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the ignition switch to ON.
Enter the following menus: Powertrain / EV / Data List / FC Work Mode, FC Intermittent Operation.
Put the state in park (P), turn the ignition switch to ON (READY) and wait until the FC system is activated (Waiting for at least 2 minutes is required after turning the ignition switch to ON (READY)).
FC system is activated: Data List shows that "FC Work Mode" is "Working" and "FC Intermittent Operation" is "OFF".
Wait at least 15 seconds with the FC system activated.
Pre-procedure1
None
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P1DDA00, P1DDB00, P1DDC00 or P1DDD00 is output | A |
| P1DDA00, P1DDB00, P1DDC00 or P1DDD00 is output and DTCs other than the DTCs in the table below are output | B |
| P1DDA00, P1DDB00, P1DDC00 or P1DDD00 is output and any DTCs in the table below are output | C |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Sensor and actuator circuit malfunction | P1D3011 | Phase U Reactor Current Sensor Circuit Short to Ground |
| P1D3015 | Phase U Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D301C | Phase U Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D3028 | Phase U Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D3511 | Phase V Reactor Current Sensor Circuit Short to Ground | |
| P1D3515 | Phase V Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D351C | Phase V Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D3528 | Phase V Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D3A11 | Phase W Reactor Current Sensor Circuit Short to Ground | |
| P1D3A15 | Phase W Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D3A1C | Phase W Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D3A28 | Phase W Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D4011 | Phase X Reactor Current Sensor Circuit Short to Ground | |
| P1D4015 | Phase X Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D401C | Phase X Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D4028 | Phase X Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D0618 | FC Converter Phase U Current Circuit Current Below Threshold | |
| P1D0718 | FC Converter Phase V Current Circuit Current Below Threshold | |
| P1D0818 | FC Converter Phase W Current Circuit Current Below Threshold | |
| P1D0918 | FC Converter Phase X Current Circuit Current Below Threshold | |
| System malfunction | P1D0F62 | Cell Monitor Voltage/FC Converter Input Voltage Signal Compare Failure |
DTC P1DDA00, P1DDB00, P1DDC00 or P1DDD00 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Pre-procedure1
None
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| P1D9512 is output | B |
DTC P1DDA00, P1DDB00, P1DDC00 or P1DDD00 may be output as a result of the malfunction indicated by the DTCs above.
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Pre-procedure1
None
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off and wait for 10 minutes or more.
NEXT
Pre-procedure1
None
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| DTCs are not output | A |
| Any of the DTCs in the table below are output | B |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Sensor and actuator circuit malfunction | P1D3011 | Phase U Reactor Current Sensor Circuit Short to Ground |
| P1D3015 | Phase U Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D301C | Phase U Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D3028 | Phase U Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D3511 | Phase V Reactor Current Sensor Circuit Short to Ground | |
| P1D3515 | Phase V Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D351C | Phase V Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D3528 | Phase V Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D3A11 | Phase W Reactor Current Sensor Circuit Short to Ground | |
| P1D3A15 | Phase W Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D3A1C | Phase W Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D3A28 | Phase W Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D4011 | Phase X Reactor Current Sensor Circuit Short to Ground | |
| P1D4015 | Phase X Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D401C | Phase X Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D4028 | Phase X Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D0618 | FC Converter Phase U Current Circuit Current Below Threshold | |
| P1D0718 | FC Converter Phase V Current Circuit Current Below Threshold | |
| P1D0818 | FC Converter Phase W Current Circuit Current Below Threshold | |
| P1D0918 | FC Converter Phase X Current Circuit Current Below Threshold | |
| System malfunction | P1D0F62 | Cell Monitor Voltage/FC Converter Input Voltage Signal Compare Failure |
DTC P1DDA00, P1DDB00, P1DDC00 or P1DDD00 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
Turn the ignition switch to ON (READY). (A)
Accelerate the vehicle to approximately 80 km/h (50 mph). (B)
While checking the Data List item "FC Current", depress the accelerator pedal and ensure that all conditions stated below are met. (C)
| Tester Display |
|---|
| FC Current |
When performing the confirmation driving pattern, obey all speed limits and traffic laws.
Data List item "FC Current" value remains 263 A or more for at least 2 seconds.
| Proceed to |
|---|
| NEXT |
NEXT
Pre-procedure1
None
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P1DDA00, P1DDB00, P1DDC00 or P1DDD00 is output | A |
| P1DDA00, P1DDB00, P1DDC00 or P1DDD00 is output and DTCs other than the DTCs in the table below are output | B |
| DTCs are not output | C |
| P1DDA00, P1DDB00, P1DDC00 or P1DDD00 is output and any DTCs in the table below are output | D |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Sensor and actuator circuit malfunction | P1D3011 | Phase U Reactor Current Sensor Circuit Short to Ground |
| P1D3015 | Phase U Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D301C | Phase U Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D3028 | Phase U Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D3511 | Phase V Reactor Current Sensor Circuit Short to Ground | |
| P1D3515 | Phase V Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D351C | Phase V Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D3528 | Phase V Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D3A11 | Phase W Reactor Current Sensor Circuit Short to Ground | |
| P1D3A15 | Phase W Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D3A1C | Phase W Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D3A28 | Phase W Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D4011 | Phase X Reactor Current Sensor Circuit Short to Ground | |
| P1D4015 | Phase X Reactor Current Sensor Circuit Short to Battery or Open | |
| P1D401C | Phase X Reactor Current Sensor Circuit Voltage Out of Range | |
| P1D4028 | Phase X Reactor Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure | |
| P1D0618 | FC Converter Phase U Current Circuit Current Below Threshold | |
| P1D0718 | FC Converter Phase V Current Circuit Current Below Threshold | |
| P1D0818 | FC Converter Phase W Current Circuit Current Below Threshold | |
| P1D0918 | FC Converter Phase X Current Circuit Current Below Threshold | |
| System malfunction | P1D0F62 | Cell Monitor Voltage/FC Converter Input Voltage Signal Compare Failure |
DTC P1DDA00, P1DDB00, P1DDC00 or P1DDD00 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
D
Pre-procedure1
None
Procedure1
Check whether the FC relay operating sound occurs when performing the Active Test on the GTS.
| Active Test Display |
|---|
| Activate the FC Positive Relay |
| Data List Display |
|---|
| FC Positive Relay Drive Request |
FC relay operating sound occurs.
| Result | Proceed to |
|---|---|
| FC relay operating sound does not occur | A |
| FC relay operating sound occurs | B |
Post-procedure1
Turn the ignition switch off.
A
B
Pre-procedure1
None
Procedure1
Check whether the FC relay operating sound occurs when performing the Active Test on the GTS.
| Active Test Display |
|---|
| Activate the FC Negative Relay |
| Data List Display |
|---|
| FC Negative Relay Drive Request |
FC relay operating sound occurs.
| Result | Proceed to |
|---|---|
| FC relay operating sound does not occur | A |
| FC relay operating sound occurs | B |
Post-procedure1
Turn the ignition switch off.
A
B
Click hereEngine / Hybrid System>FC CONTROL>CONVERTER ASSEMBLY>REMOVAL
| Proceed to |
|---|
| NEXT |
NEXT