MALFUNCTION DESCRIPTION
These DTCs indicate the temperature sensor value is abnormal. The cause of this malfunction may be one of the following:
| Area | Main Malfunction Description |
|---|---|
| Inverter low-voltage circuit | The connectors are not connected properly |
| EV cooling system | Coolant circulation abnormal (frozen or leaking, etc.) |
| Inside of inverter | Inverter with converter assembly internal circuit malfunction |
The EV control ECU detects EV coolant temperature using the coolant temperature sensor built into the inverter with converter assembly. The EV control ECU uses signals from the coolant temperature sensor to check the effectiveness of the inverter cooling system. If necessary, the EV control ECU will limit inverter output to help prevent inverter overheating. The EV control ECU also detects malfunctions in the sensor based on the coolant temperature sensor values. The inverter with converter assembly detects malfunctions in the coolant temperature sensor and its wiring.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|
| P0A001C | Motor Electronics Coolant Temperature Sensor "A" Circuit Voltage Out of Range | Abnormal deviation in icoolant temperature sensor output.
EV coolant temperature calculated by the EV control ECU is different from the actual temperature for 10 seconds or more, and the EV coolant temperature is excessively high. (1 trip detection logic) |
·
Inverter cooling system ·
Cooling fan system ·
Inverter with converter assembly ·
Wire harness or connector |
Master Warning:
Comes on |
EV | A |
| P0A001F | Motor Electronics Coolant Temperature Sensor "A" Circuit Intermittent | Sudden change in coolant temperature sensor output or hunting:
Unusual sudden change in coolant temperature sensor output occurs and the offset continues for a certain period of time. Unusual sudden change in coolant temperature sensor output occurs repeatedly. (1 trip detection logic) |
·
Inverter cooling system ·
Cooling fan system ·
Inverter with converter assembly ·
Wire harness or connector |
Master Warning:
Comes on |
EV | A |
| DTC No. | ECU Data List |
|---|---|
| P0A001C | ·
Inverter Coolant Water Temperature ·
Ambient Temperature ·
Inverter Water Pump ·
Inverter Water Pump Revolution |
| P0A001F |
After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY
Turn the ignition switch to ON (READY) and wait for 90 seconds or more.
Drive the vehicle for approximately 10 minutes referring to the following freeze frame data or Data List items: "Vehicle Speed".
Enter the following menus: Powertrain / EV / Utility / All Readiness.
Check the DTC judgment result.
If the judgment result shows NORMAL, the system is normal.
If the judgment result shows ABNORMAL, the system has a malfunction.
If the judgment result shows INCOMPLETE, perform driving pattern again.
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.
Make sure to remove the service plug grip first.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the inverter with converter assembly
Disconnecting the low voltage connector of the EV supply battery assembly
Disconnecting the low voltage connector of the FC converter assembly
Disconnecting the low voltage connector of the voltage inverter (for 1500W Type Voltage Inverter)
To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.
The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.
Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.
| *a | Without waiting for 10 minutes |
After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the electric vehicle charger assembly.
Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.
If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.
After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.
When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| P0A001C or P0A001F only is output, or DTCs except the ones in the table below are also output. | A |
| Any of the following DTCs are also output. | B |
| Malfunction Content | Relevant DTC | |
|---|---|---|
| Sensor and actuator circuitmalfunction | P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure |
| P314A31 | Motor Electronics Coolant Pump "A" No Signal | |
| System malfunction | P0A9300 | Inverter "A" Cooling System Performance |
P0A001C or P0A001F may be output as a result of the malfunction indicated by the DTCs above.
Post-procedure1
Turn the ignition switch off.
A
B
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip and FC converter power outlet cable are not installed.
After removing the service plug grip and FC converter power outlet cable, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Procedure1
Check the connection condition of the low voltage connector of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
| *A | for LHD | *B | for RHD |
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connector.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
Post-procedure1
None.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Cooling System
| Proceed to |
|---|
| NEXT |
NEXT