Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM › from 2021.08
RM37H0E _51 Engine / Hybrid System _096346 HYBRID / BATTERY CONTROL _0463852 HYBRID CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  P0CA300  DC/DC Converter Step Up Voltage Performance  


DTC SUMMARY

MALFUNCTION DESCRIPTION


This DTC indicates that it has been detected that the VH voltage cannot be boosted as commanded due to malfunction of the boost converter system. The cause of this malfunction may be one of the following:

Internal inverter malfunction

Inverter with converter assembly internal circuit malfunction


Inverter low-voltage circuit malfunction

The connectors are not connected properly



DESCRIPTION

The boost converter boosts the 310.8 V DC from the EV supply battery assembly to a maximum of approximately 650 V DC. The inverter converts the voltage that has been boosted by the boost converter into alternating current, which is used for driving FC air compressor motor and drive motor. When a drive motor operates as a generator, the alternating current that it creates is converted into direct current by the inverter. Then the boost converter drops this voltage to direct current of approximately 310.8 V in order to charge the EV supply battery assembly.

A105188E27
6.448,2.25 6.635,2.573 false 2.542,0.417 4.708,0.667 2.167,0.25 10 false Inverter with Converter Assembly 1.375,0.979 2.427,1.208 1.052,0.229 10 false Boost Converter 0.125,2.771 0.802,3.313 0.677,0.542 10 false EV Supply Battery Assembly 0.594,3.948 1.667,4.375 1.073,0.427 10 false Before boosting direct current 3.167,3.948 4.167,4.365 1,0.417 10 false After boosting direct current 5.531,4.198 6.729,4.604 1.198,0.406 10 false After converting alternating current 1.729,3.083 3,3.323 1.271,0.24 10 false Voltage Conversion 6.094,2.615 7.156,2.948 1.063,0.333 10 false Motor Generator

The MG ECU uses a voltage sensor (VL) that is built into the boost converter to detect the high voltage before it is boosted. It also uses a voltage sensor (VH) that is built into the inverter to detect the high voltage after it is boosted. Based on the voltage before and after it is boosted, the MG ECU controls the operation of the boost converter to boost the voltage to the target voltage.

DTC No. Detection Item DTC Detection Condition Trouble Area Warning Indicate DTC Output from Priority
P0CA300 DC/DC Converter Step Up Voltage Performance Abnormal voltage execution value:
Boosting cannot be performed as requested due to a boost converter system malfunction.
(1 trip detection logic)
·

Wire harness or connector

·

Inverter with converter assembly


Master Warning:
Comes on
EV A

HINT:

With the vehicle stopped, apply the parking brake and turn the ignition switch to ON (READY).

With the shift lever in P, depress the brake pedal firmly, and quickly and fully depress the accelerator pedal.

Immediately after the accelerator pedal is fully depressed, "VH-Voltage after boosting" will be between 450 and 650 V.


Related Data List
DTC No. Data List
P0CA300 VH-Voltage after Boosting

CONFIRMATION DRIVING PATTERN

HINT:

After repairs have been completed, clear the DTCs and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>UTILITY


1.

Enter the following menus: Powertrain / EV / Data List / FC Work Mode, FC IntermittentOperation.

2.

Push the P position switch (shift position indicator) to select park (P), turn the ignition switch to ON (READY) and wait until the FCsystem is started. Waiting for at least 2 minutes is required after turning the ignition switch to ON (READY).

- FC system is started: "Working" is displayed for the Data List item "FC Work Mode" and "FC Intermittent Operation" is OFF.

3.

With the FC system operating, wait for 15 seconds or more.

4.

Enter the following menus: Powertrain / EV / Utility / All Readiness.

5.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the EV battery service plug grip and FC converter power outlet cable on FC converter side.

Make sure to remove the service plug grip first.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the inverter with converter assembly

-

Disconnecting the low voltage connector of the EV supply battery assembly

-

Disconnecting the low voltage connector of the FC converter assembly

-

Disconnecting the low voltage connector of the voltage inverter (for 1500W Type Voltage Inverter)


·
A484004

To prevent electric shock, make sure to remove the EV battery service plug grip and FC converter power outlet cable on FC converter side to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, store them according to the following guidelines to prevent other technicians from accidentally reconnecting them while work is being performed on the high voltage systems.

-

The technician performing the work should put the EV battery service plug grip in their pocket and carry it with them.

-

Remove the FC converter power outlet cable on FC converter side with a "HIGH-VOLTAGE, DO NOT TOUCH" caution tag attached to it for other technicians.


·
A484005C01
1.667,0.74 2.115,0.427 true 2.188,0.385 2.448,0.552 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the EV battery service plug grip and FC converter power outlet cable on FC converter side, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly and the FC converter assembly.


·

Make sure to insulate the high-voltage connectors and terminals of the EV supply battery assembly with insulating tape after removing it.

If the EV supply battery assembly stored without insulating the connectors and terminals, electric shock or fire may result.



NOTICE:
·

After turning the ignition switch off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART


·

This vehicle performs FC system shutdown process after turning the ignition switch off from ON (READY). Therefore, after the ignition switch is turned off from ON (READY), do not perform any work on the electrical system for at least 10 minutes including removing connectors or disconnecting the negative (-) auxiliary battery terminal.

·

When the EV control ECU determines that the temperature of FC system components is below 0°C (32°F) when the vehicle is parked with the ignition switch off, it operates the FC air compressor, hydrogen pump and FC cooling water pump for a maximum of 180 seconds to drain the FC stack assembly. When performing inspection or repairs with the ignition switch off (not ON or ON (READY)), disconnect the cable from the negative (-) auxiliary battery terminal before performing work. (If the auxiliary battery voltage is needed to conduct inspection, perform the inspection in an environment with an ambient temperature of 10°C (50°F) or higher.)



PROCEDURE

1.CHECK DTC OUTPUT (EV)

Pre-procedure1

a.

None.


Procedure1

a.

Check for DTCs.

Powertrain > EV > Trouble Codes
50001 397
Result:
Result Proceed to
P0CA300 only is output, or DTCs except the ones in the table below are also output. A
Any of the following DTCs are also output. B

Malfunction Content Relevant DTC
Insulation Malfunction P1C7C49 Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
P1C7D49 Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure
P1C7E49 Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure
P1C7F49 Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure
P1EEC49 Hybrid/EV Battery Voltage System Isolation (FC Air Compressor Area) Internal Electronic Failure
P1EED49 Hybrid/EV Battery Voltage System Isolation (FC Area) Internal Electronic Failure
P1EEE49 Hybrid/EV Battery Voltage System Isolation (Hydrogen Pump Area) Internal Electronic Failure
P1EEF49 Hybrid/EV Battery Voltage System Isolation (FC Coolant Pump Area) Internal Electronic Failure
High Voltage Circuit Malfunction P0AD911 Hybrid/EV Battery Positive Contactor Circuit Short to Ground
P0AD915 Hybrid/EV Battery Positive Contactor Circuit Short to Auxiliary Battery or Open
P0ADD11 Hybrid/EV Battery Negative Contactor Circuit Short to Ground
P0ADD15 Hybrid/EV Battery Negative Contactor Circuit Short to Auxiliary Battery or Open
P1C8449 High Voltage Power Resource Circuit Short during Ready ON


HINT:
·

P0CA300 may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





Post-procedure1

a.

Turn the ignition switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

B

GO TO DTC CHART (HYBRID CONTROL SYSTEM)

2.CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A001C

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

REPLACE INVERTER WITH CONVERTER ASSEMBLY

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR