For a description of the inverter (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A78-266).
If the motor inverter overheats, has a circuit malfunction, or has an internal short, the inverter transmits this information to the MG ECU via the motor inverter fail signal line.
The term "drive motor A" indicates MG2.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A78 | 113 | Motor inverter fail signal detection
(System overcurrent) |
·
Wire harness or connector ·
Hybrid vehicle transaxle assembly ·
Motor cable ·
Inverter with converter assembly ·
Power management control ECU ·
PCU fuse |
Refer to the wiring diagram for DTC P0A1A-200 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0A1A-200).
Refer to the wiring diagram for DTC P0AA6-526 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0AA6-526).
Refer to the wiring diagram for DTC P324E-788 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P324E-788).
Refer to the wiring diagram for DTC U0110-159 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>U0110-159).
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (READY) and wait for 5 seconds or more.
Perform a road test according to the freeze frame data "Vehicle Spd" for approximately 10 minutes.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A78-113 is set before any of the DTCs in the table below are set. | A |
| Any of the DTCs including pending DTCs in the table 1 below are set before P0A78-113 is set. | B |
| Any of the DTCs in the table 2 below are set before P0A78-113 is set. | C |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P3004-803 | High Voltage Power Resource |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A9C-123 | Hybrid Battery Temperature Sensor "A" Range / Performance |
| P0A9D-123 | Hybrid Battery Temperature Sensor "A" Circuit Low |
| P0A9E-123 | Hybrid Battery Temperature Sensor "A" Circuit High |
| P0AC0-123 | Hybrid Battery Pack Current Sensor Circuit Range / Performance |
| P0AC1-123 | Hybrid Battery Pack Current Sensor Circuit Low |
| P0AC2-123 | Hybrid Battery Pack Current Sensor Circuit High |
| P0AC6-123 | Hybrid Battery Temperature Sensor "B" Range / Performance |
| P0AC7-123 | Hybrid Battery Temperature Sensor "B" Circuit Low |
| P0AC8-123 | Hybrid Battery Temperature Sensor "B" Circuit High |
| P0ACB-123 | Hybrid Battery Temperature Sensor "C" Range / Performance |
| P0ACC-123 | Hybrid Battery Temperature Sensor "C" Circuit Low |
| P0ACD-123 | Hybrid Battery Temperature Sensor "C" Circuit High |
| P0AFC-123 | Hybrid Battery Pack Sensor Module |
| P3011-123, P3012-123, P3013-123, P3014-123, P3015-123, P3016-123, P3017-123, P3018-123, P3019-123, P3020-123 | Battery Block # Becomes Weak |
| P3065-123 | Hybrid Battery Temperature Sensor Range / Performance Stuck "A" |
| P308A-123 | Hybrid Battery Voltage Sensor All Circuits Low |
Refer to the Freeze Frame data to determine the order in which the DTCs were set.
P0A78-113 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
Turn the power switch off.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
C
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A78-202 is not output. | A |
| P0A78-202 is also output. | B |
If P0A78-202 is output, troubleshoot it first. After completing the troubleshooting for P0A78-202, return to perform troubleshooting for this DTC.
Parts repaired or replaced during troubleshooting for P0A78-202 do not need to be re-inspected in this diagnosis procedure.
Turn the power switch off.
A
B
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
If P0A78-202 was not output in step 2 of this diagnosis procedure, check Table 1 below.
If P0A78-202 was output in step 2 of this diagnosis procedure, repair that DTC first, then check Table 2 below.
| Result | Proceed to |
|---|---|
| Only P0A78-113 is output, or DTCs other than the ones in the table below are also output. | A |
| Any of the following DTCs including pending DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-266, 267, 279, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808 | Drive Motor "A" Inverter Performance |
| P0A7A-325, 344, 517, 518, 809, 810, 811 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590 | DC / DC Converter Performance |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P3004-803 | High Voltage Power Resource |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A60-294 | Drive Motor "A" Phase V Current |
| P0A63-302 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-266, 267, 279, 287, 503, 504, 505, 506, 586, 806, 807, 808 | Drive Motor "A" Inverter Performance |
| P0A7A-325, 344, 517, 518, 809, 810, 811 | Generator Inverter Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590 | DC / DC Converter Performance |
| P0ADB-227 | Hybrid Battery Positive Contactor Control Circuit Low |
| P0ADC-226 | Hybrid Battery Positive Contactor Control Circuit High |
| P0ADF-229 | Hybrid Battery Negative Contactor Control Circuit Low |
| P0AE0-228 | Hybrid Battery Negative Contactor Control Circuit High |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P3004-803 | High Voltage Power Resource |
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0A78-113 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
Turn the power switch off.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
OK
NG
OK
NG
OK
NG
OK
NG
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Remove the inverter cover from the inverter with converter assembly.
Check that the bolts for the motor cable (for MG1) are tightened to the specified torque, the motor cable (for MG1) is connected securely, and there are no contact problems.
T=8.0 N*m (82 kgf*cm, 71 in.*lbf)
T=9.2 N*m (94 kgf*cm, 81 ft.*lbf)
Make sure that the tightening torque of the bolt B is between 6.4 and 12 N*m (65 and 122 kgf*cm, 57 and 106 in.*lbf).
Disconnect the motor cable (for MG1) from the inverter with converter assembly.
Check for arc marks at the terminals for the motor cable (for MG1).
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG1) to the inverter with converter assembly.
Install the inverter cover.
Install the inverter terminal cover.
A
B
C
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Check that the bolts for the motor cable (for MG2) are tightened to the specified torque, the motor cable (for MG2) is connected securely, and there are no contact problems.
T=8.0 N*m (82 kgf*cm, 71 in.*lbf)
T=9.2 N*m (94 kgf*cm, 81 ft.*lbf)
Make sure that the tightening torque of the bolt B is between 6.4 and 12 N*m (65 and 122 kgf*cm, 57 and 106 in.*lbf).
Disconnect the motor cable (for MG2) from the inverter with converter assembly.
Check for arc marks at the terminals for the motor cable (for MG2).
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG2) to the inverter with converter assembly.
Install the inverter terminal cover.
A
B
C
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Remove the inverter cover from the inverter with converter assembly.
Disconnect the motor cable from the inverter with converter assembly.
Check MG1 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| a2-1 (W) - a2-2 (U) | Power switch off | 139.1 to 153.7 mΩ |
| a2-2 (U) - a2-3 (V) | Power switch off | 139.1 to 153.7 mΩ |
| a2-3 (V) - a2-1 (W) | Power switch off | 139.1 to 153.7 mΩ |
| *1 | Shield Ground |
| *a | Motor Cable (for MG1)
(Inverter with Converter Assembly Side) |
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68° F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| a2-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
Connect the motor cable.
Install the inverter cover.
Install the inverter terminal cover.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Remove the inverter cover from the inverter with converter assembly.
Disconnect the motor cable from the inverter with converter assembly.
Check MG2 for an interphase short using a milliohmmeter.
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
If the MG2 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| a4-1 (W) - a4-2 (U) | Power switch off | 172.5 to 190.7 mΩ |
| a4-2 (U) - a4-3 (V) | Power switch off | 172.5 to 190.7 mΩ |
| a4-3 (V) - a4-1 (W) | Power switch off | 172.5 to 190.7 mΩ |
| *1 | Shield Ground |
| *a | Motor Cable (for MG2)
(Inverter with Converter Assembly Side) |
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68° F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C)
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| a4-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
Connect the motor cable.
Install the inverter cover.
Install the inverter terminal cover.
OK
NG
Remove the PCU fuse from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| PCU fuse terminal | Always | Below 1Ω |
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly |
| *2 | PCU fuse |
Install the PCU fuse.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A47 from inverter with converter assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A47-28 (GND1) - Body ground | Power switch off | Below 1 Ω |
| A47-27 (GND2) - Body ground | Power switch off | Below 1 Ω |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A47-10 (+B) - Body ground | Power switch on (IG) | Same as auxiliary battery voltage |
| A47-9 (+B2) - Body ground | Power switch on (IG) | Same as auxiliary battery voltage |
Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the inverter with converter assembly connector.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A47 from the inverter with converter assembly.
Disconnect connector A39 from the power management control ECU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A47-8 (HTM+) - A39-24 (HTM+) | Power switch off | Below 1 Ω |
| A47-18 (HTM-) - A39-25 (HTM-) | Power switch off | Below 1 Ω |
| A47-7 (MTH+) - A39-30 (MTH+) | Power switch off | Below 1 Ω |
| A47-17 (MTH-) - A39-29 (MTH-) | Power switch off | Below 1 Ω |
| A47-6 (REQ+) - A39-33 (REQ+) | Power switch off | Below 1 Ω |
| A47-16 (REQ-) - A39-32 (REQ-) | Power switch off | Below 1 Ω |
| A47-5 (CLK+) - A39-21 (CLK+) | Power switch off | Below 1 Ω |
| A47-15 (CLK-) - A39-20 (CLK-) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A47-8 (HTM+) or A39-24 (HTM+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-18 (HTM-) or A39-25 (HTM-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-7 (MTH+) or A39-30 (MTH+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-17 (MTH-) or A39-29 (MTH-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-6 (REQ+) or A39-33 (REQ+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-16 (REQ-) or A39-32 (REQ-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-5 (CLK+) or A39-21 (CLK+) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| A47-15 (CLK-) or A39-20 (CLK-) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector
(to Power Management Control ECU) |
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A47-8 (HTM+) or A39-24 (HTM+) - Body ground | Power switch on (IG) | Below 1 V |
| A47-18 (HTM-) or A39-25 (HTM-) - Body ground | Power switch on (IG) | Below 1 V |
| A47-7 (MTH+) or A39-30 (MTH+) - Body ground | Power switch on (IG) | Below 1 V |
| A47-17 (MTH-) or A39-29 (MTH-) - Body ground | Power switch on (IG) | Below 1 V |
| A47-6 (REQ+) or A39-33 (REQ+) - Body ground | Power switch on (IG) | Below 1 V |
| A47-16 (REQ-) or A39-32 (REQ-) - Body ground | Power switch on (IG) | Below 1 V |
| A47-5 (CLK+) or A39-21 (CLK+) - Body ground | Power switch on (IG) | Below 1 V |
| A47-15 (CLK-) or A39-20 (CLK-) - Body ground | Power switch on (IG) | Below 1 V |
Turning the power switch on (IG) with the power management control ECU and inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the power switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Connect the power management control ECU connector.
Connect the inverter with converter assembly connector.
OK
NG
Disconnect connector A39 from the power management control ECU.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A39-24 (HTM+) - A39-25 (HTM-) | Power switch off | 80 to 170 Ω |
| A39-30 (MTH+) - A39-29 (MTH-) | Power switch off | 80 to 170 Ω |
| A39-33 (REQ+) - A39-32 (REQ-) | Power switch off | 80 to 170 Ω |
| A39-21 (CLK+) - A39-20 (CLK-) | Power switch off | 80 to 170 Ω |
| *a | Component without harness connected
(Power Management Control ECU) |
Connect the power management control ECU connector.
OK
NG
OK
NG
OK
NG
OK
NG
Connect the intelligent tester to the DLC3.
Turn the power switch on (READY) and wait for 5 seconds or more.
Perform a road test according to the freeze frame data "Vehicle Spd" for approximately 10 minutes.
Enter the following menus: Powertrain / Hybrid Control / DTC.
Check if DTCs are output.
| Result | Proceed to |
|---|---|
| P0A78-113 is output. | A |
| P0A78-113 is not output. | B |
If the connector engagement check and cleaning caused the condition to return to normal, DTCs will not be output.
Turn the power switch off.
A
B
OK
NG
OK
NG
OK
NG
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect connector A47 from the inverter with converter assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A47-10 (+B) - Body ground | Power switch off | 10 kΩ or higher |
| A47-9 (+B2) - Body ground | Power switch off | 10 kΩ or higher |
| *a | Front view of wire harness connector
(to Inverter with Converter Assembly) |
Connect the inverter with converter assembly connector.
OK
NG
NEXT
NEXT
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter with converter assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>COMPONENTS).
Check that the bolts for the motor cable (for MG1) are tightened to the specified torque, the motor cable (for MG1) is connected securely, and there are no contact problems.
T=19.5 N*m (199 kgf*cm, 14 ft.*lbf)
T=10 N*m (102 kgf*cm, 7 ft.*lbf)
Make sure that the tightening torque of the bolt A is between 13.5 and 25 N*m (138 and 255 kgf*cm, 10 and 18 ft.*lbf).
Make sure that the tightening torque of the bolt B is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).
Disconnect the motor cable (for MG1) from the hybrid vehicle transaxle assembly.
Check for arc marks at the terminals for the motor cable (for MG1).
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG1) to the hybrid vehicle transaxle assembly.
Install the inverter with converter assembly.
A
B
C
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the motor cable (See page Drivetrain>P510 (HYBRID TRANSMISSION / TRANSAXLE)>MOTOR CABLE>COMPONENTS).
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| a2-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a2-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Shield ground |
| *a | Motor Cable (for MG1)
(Inverter with Converter Assembly Side) |
| *b | Motor Cable (for MG1)
(Hybrid Vehicle Transaxle Assembly Side) |
Wrap the terminal of the motor cable (for MG1) with insulating tape to prevent them from coming into contact with body ground
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| a2-1 (W) - a1-1 (W) | Power switch off | Below 1 Ω |
| a2-2 (U) - a1-2 (U) | Power switch off | Below 1 Ω |
| a2-3 (V) - a1-3 (V) | Power switch off | Below 1 Ω |
| a2-1 (W) - a1-2 (U) | Power switch off | 100 MΩ or higher |
| a2-2 (U) - a1-3 (V) | Power switch off | 100 MΩ or higher |
| a2-3 (V) - a1-1 (W) | Power switch off | 100 MΩ or higher |
Install the motor cable.
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Check that the bolts for the motor cable (for MG2) are tightened to the specified torque, the motor cable (for MG2) is connected securely, and there are no contact problems.
T=19.5 N*m (199 kgf*cm, 14 ft.*lbf)
T=10 N*m (102 kgf*cm, 7 ft.*lbf)
Make sure that the tightening torque of the bolt A is between 13.5 and 25 N*m (138 and 255 kgf*cm, 10 and 18 ft.*lbf).
Make sure that the tightening torque of the bolt B is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).
Disconnect the motor cable (for MG2) from the hybrid vehicle transaxle assembly.
Check for arc marks at the terminals for the motor cable (for MG2).
| Result | Proceed to | |
|---|---|---|
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
Connect the motor cable (for MG2) to the hybrid vehicle transaxle assembly.
A
B
C
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the motor cable (See page Drivetrain>P510 (HYBRID TRANSMISSION / TRANSAXLE)>MOTOR CABLE>COMPONENTS).
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| a4-1 (W) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-2 (U) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| a4-3 (V) - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| *1 | Shield ground |
| *a | Motor Cable (for MG2)
(Inverter with Converter Assembly Side) |
| *b | Motor Cable (for MG2)
(Hybrid Vehicle Transaxle Assembly Side) |
Wrap the terminal of the motor cable (for MG2) with insulating tape to prevent them from coming into contact with body ground
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| a4-1 (W) - a3-1 (W) | Power switch off | Below 1 Ω |
| a4-2 (U) - a3-3 (U) | Power switch off | Below 1 Ω |
| a4-3 (V) - a3-2 (V) | Power switch off | Below 1 Ω |
| a4-1 (W) - a3-3 (U) | Power switch off | 100 MΩ or higher |
| a4-2 (U) - a3-2 (V) | Power switch off | 100 MΩ or higher |
| a4-3 (V) - a3-1 (W) | Power switch off | 100 MΩ or higher |
Install the motor cable.
OK
NG