Refer to the description for DTC P0C73-776 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0C73-776).
The inverter water pump assembly sends the water pump speed (measured value) signal to the power management control ECU. If the inverter water pump speed (measured value) signal is not sent to the power management control ECU when the power switch is on (READY), this DTC is stored.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P314A | 828 | The water pump speed signal is not sent to the power management control ECU when the ignition switch is turned on (READY) or water pump revolution speed is extremely low or stop.*1
(1 trip detection logic) |
·
Wire harness or connector ·
Power management control ECU ·
Inverter water pump assembly ·
IGCT NO. 3 fuse |
*1: Malfunction (open, short to +B or short to ground) in the speed signal line from the inverter water pump assembly or inverter water pump assembly power source circuit malfunction is suspected.
A malfunction (open, short to +B or short to ground) in the speed signal line from the inverter water pump assembly to the power management control computer is detected.
A malfunction in the inverter water pump assembly power source circuit is detected.
A malfunction in the +B line or speed signal line to the inverter water pump assembly is detected.
A malfunction in the inverter water pump assembly power source circuit or power management control computer power source circuit is detected.
| DTC No. | Data List |
|---|---|
| P314A-828 | ·
Inverter W/P Revolution*2 ·
W/P Run Control Duty*2 ·
Ready Signal |
*2: This Data List item is related to the inverter water pump assembly.
| DTC No. | Active Test |
|---|---|
| P314A-828 | Activate the Water Pump*3 |
*3: This is an Active Test of the inverter water pump assembly.
Refer to the wiring diagram for DTC P0C73-776 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>P0C73-776).
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Turn the power switch on (READY) and wait for 2 minutes or more.
NEXT
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Perform the Activate the Water Pump Active Test.
Touch the inverter water pump assembly and check that it is operating (vibrating).
The inverter water pump is operating (vibrating).
Turn the power switch off.
OK
NG
OK
NG
OK
NG
Disconnect connector A38 from the power management control ECU.
Disconnect connector A53 from the inverter water pump assembly.
Measure the resistance according to the value(s) in the table below.
| *a | Rear view of wire harness connector
(to Power Management Control ECU) |
*b | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-14 (NIWP) - A53-2 (NWP) | Power switch off | Below 1 Ω |
| A38-14 (NIWP) or A53-2 (NWP) -Body ground and other terminals | Power switch off | 10 kΩ or higher |
Check the condition (looseness, deterioration, etc.) of the wire to body ground for the inverter water pump assembly.
Connect the power management control ECU connector.
Connect the inverter water pump assembly connector.
OK
NG
Disconnect connector A53 from the inverter water pump assembly.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A38-14 (NIWP) - G57-6 (E1) | Power switch on (IG) | 11 to 14 V |
| *a | Component with harness connected
(Power Management Control ECU) |
Turn the power switch off.
Connect the inverter water pump assembly connector.
OK
NG
NEXT
Be sure to perform the inspection with the auxiliary battery voltage at 11 V or more.
When the auxiliary battery voltage is low, the inverter water pump assembly may not operate.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Active Test / Activate the Water Pump.
Perform the "Activate the Water Pump" Active Test.
Connect an oscilloscope between the power management control ECU terminals specified in the table below, and measure the waveform.
| Item | Content |
|---|---|
| Terminal | A38-14 (NIWP) - G57-6 (E1) |
| Equipment Setting | 5 V/DIV., 100 ms./DIV. |
| Condition | Ignition switch ON (IG), during Active Test |
The duration of wavelength A is 300 msec or less.
| *a | Component with harness connected
(Power Management Control ECU) |
Turn the power switch off.
OK
NG
OK
NG
Remove the IGCT relay from the No. 2 engine room relay block and No. 2 junction block assembly.
Disconnect connector A53 from the inverter water pump assembly.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly | *2 | IGCT Relay |
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
- | - |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A53-4 (+BWP) - 5 (IGCT relay) | Ignition switch off | Below 1 Ω |
Connectors
Slightly shake the connector vertically and horizontally.
Wire Harness
Slightly shake the wire harness vertically and horizontally.
The connector joint and fulcrum of the vibration are the major areas that should be checked thoroughly.
No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly
Apply slight vibration with a finger to the No. 2 engine room relay block and No. 2 junction block assembly and check whether a malfunction occurs.
IGCT NO. 3 Fuse
Apply slight vibration with a finger to the IGCT NO. 3 fuse and check whether a malfunction occurs.
| *a | Example |
| *b | Shake Slightly |
| *c | Vibrate Slightly |
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
Install the IGCT relay.
Connect the inverter water pump assembly connector.
OK
NG
Disconnect connector A53 from the inverter water pump assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A53-1 (GND) - Body ground | Ignition switch off | Below 1 Ω |
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
Connect the inverter water pump assembly connector.
OK
NG
Remove the IGCT NO. 3 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGCT NO. 3 fuse | Always | Below 1Ω |
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly |
| *2 | IGCT NO. 3 Fuse |
Install the IGCT NO. 3 fuse.
OK
NG
Check the terminals of the IGCT NO. 3 fuse holder.
The terminals of the IGCT NO. 3 fuse holder are not bent, loose or corroded.
OK
NG
Remove the IGCT NO. 3 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.
Remove the IGCT relay from the No. 2 engine room relay block and No. 2 junction block assembly.
Disconnect connector A53 from the inverter water pump assembly.
Measure the resistance according to the value(s) in the table below.
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly | *2 | IGCT NO. 3 Fuse |
| *3 | IGCT Relay | - | - |
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
- | - |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A53-4 (+BWP) - 2 (IGCT NO. 3 fuse) | Ignition switch off | Below 1 Ω |
| 1 (IGCT NO. 3 fuse) - 5 (IGCT relay) | Ignition switch off | Below 1 Ω |
| A53-4 (+BWP) or 2 (IGCT NO. 3 fuse) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
| 1 (IGCT NO. 3 fuse) or 5 (IGCT relay) - Body ground and other terminals | Ignition switch off | 10 kΩ or higher |
Do not apply excessive force when using the probes of the tester to perform the inspection. If excessive force is used, the terminals will be damaged.
Install the IGCT NO. 3 fuse.
Install the IGCT relay.
Connect the inverter water pump assembly connector.
OK
NG
Remove the IGCT NO. 3 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGCT NO. 3 fuse | Always | Below 1Ω |
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly |
| *2 | IGCT NO. 3 Fuse |
Install the IGCT NO. 3 fuse.
OK
NG
Check the terminals of the IGCT NO. 3 fuse holder.
The terminals of the IGCT NO. 3 fuse holder are not bent, loose or corroded.
OK
NG
Remove the IGCT NO. 3 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGCT NO. 3 fuse | Always | Below 1Ω |
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly |
| *2 | IGCT NO. 3 Fuse |
Install the IGCT NO. 3 fuse.
OK
NG
Remove the IGCT NO. 3 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGCT NO. 3 fuse | Always | Below 1Ω |
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly |
| *2 | IGCT NO. 3 Fuse |
Install the IGCT NO. 3 fuse.
OK
NG
Disconnect connector A53 from the inverter water pump assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| A53-1 (GND) - Body ground | Ignition switch off | Below 1 Ω |
| *a | Front view of wire harness connector
(to Inverter Water Pump Assembly) |
Connect the inverter water pump assembly connector.
OK
NG
Check the terminals of the IGCT NO. 3 fuse holder.
The terminals of the IGCT NO. 3 fuse holder are not bent, loose or corroded.
OK
NG
NEXT
After replacing the inverter water pump assembly, add HV coolant and perform air bleeding.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>COOLANT(for Inverter)>REPLACEMENT
NEXT
Remove the IGCT NO. 3 fuse from the No. 2 engine room relay block and No. 2 junction block assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| IGCT NO. 3 fuse | Always | Below 1Ω |
| *1 | No. 2 Engine Room Relay Block and No. 2 Junction Block Assembly |
| *2 | IGCT NO. 3 Fuse |
Install the IGCT NO. 3 fuse.
OK
NG
Connect the inverter water pump assembly connector securely.
NEXT
NEXT
NEXT
NEXT
After replacing the inverter water pump assembly, add HV coolant and perform air bleeding.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>COOLANT(for Inverter)>REPLACEMENT
NEXT