The operation of the compressor with motor assembly is stopped and a DTC is stored if the rotation load is too large or too small while the compressor with motor assembly is operating.
Possible causes are refrigerant leaks, overcharged refrigerant, insufficient cooling because of a condenser fan circuit malfunction, or compressor lock.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1476/76 | Motor rotation load while the compressor is operating is too large or too small. | ·
Refrigerant volume ·
Compressor with motor assembly ·
Cooling fan system ·
CAN communication system |
Wear insulated gloves and pull out the service plug grip before inspection as procedures may require disconnecting high-voltage connectors. Carry the removed service plug in your pocket to prevent other technicians from accidentally reconnecting it while you are servicing the vehicle.
Do not touch the high-voltage connectors or terminals for 10 minutes after the service plug grip is removed.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
The hybrid control system and air conditioning system output DTCs separately. Inspect DTCs following the diagnosis procedure for the hybrid control system first if any DTCs from those systems are output simultaneously.
Use the intelligent tester to check if the CAN communication system is functioning normally.
| Result | Proceed to |
|---|---|
| CAN DTC is not output | A |
| CAN DTC is output | B |
A
B
(See pagePower Source / Network>NETWORKING>CAN COMMUNICATION SYSTEM>HOW TO PROCEED WITH TROUBLESHOOTING)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Electrical Fan | Electrical fan | OFF, ON | - |
Electric cooling fan operates smoothly.
OK
NG
Install a manifold gauge set (See page Vehicle Interior>HEATING / AIR CONDITIONING>REFRIGERANT>ON-VEHICLE INSPECTION).
Read the manifold gauge pressure when the following conditions are established.
Prepare the vehicle according to the chart below.
| Item | Condition |
|---|---|
| Vehicle Doors | All fully open |
| Temperature Setting | MAX COLD |
| Blower Speed | HI |
| A/C switch | ON |
| R/F Switch | RECIRCULATION
(30 to 35°C (86 to 95°F)) |
0.15 to 0.25 MPa (1.5 to 2.5 kgf/cm2, 21.3 to 35.6 psi)
1.37 to 1.57 MPa (14 to 16 kgf/cm2, 199 to 228 psi)
OK
NG