The power management control ECU alerts the driver and performs fail-safe control based on error signals sent from the battery smart unit.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P31AB | 123 | When battery cells are over discharged
(1 trip detection) |
·
HV battery ·
Battery smart unit ·
Frame wire ·
Wire harness or connector ·
Hybrid battery junction block assembly ·
Inverter with converter assembly |
Refer to the wiring diagram for DTC P301A-123 (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>P301A-123).
This DTC may be stored even when the SOC is high.
Do not perform "HV Batt Cell Low Volt READY ON Prevention Cancel" unless specifically directed by the troubleshooting procedure. Doing so may cause a serious malfunction.
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>PRECAUTION).
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
When disposing of HV battery, make sure to return them through an authorized collection agent who is capable of handling them safely. If they are returned via the manufacturer specified route, they will be returned properly and in a safe manner by an authorized collection agent.
Before returning the HV battery, make sure to perform a recovery inspection (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>RECOVERY INSPECTION)
Make a note of the output DTCs as some of them may be necessary for recovery inspection of the HV battery.
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work (See page General>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION).
A
B
Before repairing or replacing the malfunctioning part, do not perform "HV Batt Cell Low Volt READY ON Prevention Cancel".
While depressing the brake pedal, press the power switch and check that the hybrid system turns on (READY).
Do not turn the power switch on (READY) repeatedly.
Doing so may cause a malfunction.
| Result | Proceed to |
|---|---|
| Hybrid system starts. | A |
| Hybrid system does not start. | B |
Turn the power switch off.
A
B
A
B
OK
NG
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the No. 1 hybrid battery shield sub-assembly (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HV BATTERY>REMOVAL).
Disconnect the z32 battery smart unit connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Hybrid Battery Cell | Switch Condition | Specified Condition |
|---|---|---|---|
| z32-13 (GA0) - z32-9 (VA1) | 1 | Power switch off | 3.0 V or more |
| z32-9 (VA1) -z32-5 (VA2) | 2 | Power switch off | 3.0 V or more |
| z32-5 (VA2) - z32-1 (VA3) | 3 | Power switch off | 3.0 V or more |
| z32-1 (VA3) - z32-14 (VA4) | 4 | Power switch off | 3.0 V or more |
| z32-14 (VA4) - z32-10 (VA5) | 5 | Power switch off | 3.0 V or more |
| z32-10 (VA5) - z32-6 (VA6) | 6 | Power switch off | 3.0 V or more |
| z32-6 (VA6) - z32-2 (VA7) | 7 | Power switch off | 3.0 V or more |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Hybrid Battery Cell | Switch Condition | Specified Condition |
|---|---|---|---|
| z32-2 (VA7) - z32-15 (VA8) | 8 | Power switch off | 3.0 V or more |
| z32-15 (VA8) - z32-11 (VA9) | 9 | Power switch off | 3.0 V or more |
| z32-11 (VA9) - z32-7 (VA10) | 10 | Power switch off | 3.0 V or more |
| z32-7 (VA10) - z32-16 (VA11) | 11 | Power switch off | 3.0 V or more |
| z32-16 (VA11) - z32-12 (VA12) | 12 | Power switch off | 3.0 V or more |
| z32-12 (VA12) - z32-8 (VA13) | 13 | Power switch off | 3.0 V or more |
| z32-8 (VA13) - z32-4 (VA14) | 14 | Power switch off | 3.0 V or more |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.
Reconnect the z32 battery smart unit connector.
Disconnect the z33 battery smart unit connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Hybrid Battery Cell | Switch Condition | Specified Condition |
|---|---|---|---|
| z33-11 (GA1) - z33-6 (VA15) | 15 | Power switch off | 3.0 V or more |
| z33-6 (VA15) - z33-1 (VA16) | 16 | Power switch off | 3.0 V or more |
| z33-1 (VA16) - z33-12 (VA17) | 17 | Power switch off | 3.0 V or more |
| z33-12 (VA17) - z33-7 (VA18) | 18 | Power switch off | 3.0 V or more |
| z33-7 (VA18) - z33-2 (VA19) | 19 | Power switch off | 3.0 V or more |
| z33-2 (VA19) - z33-13 (VA20) | 20 | Power switch off | 3.0 V or more |
| z33-13 (VA20) - z33-8 (VA21) | 21 | Power switch off | 3.0 V or more |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Hybrid Battery Cell | Switch Condition | Specified Condition |
|---|---|---|---|
| z33-8 (VA21) - z33-3 (VA22) | 22 | Power switch off | 3.0 V or more |
| z33-3 (VA22) - z33-14 (VA23) | 23 | Power switch off | 3.0 V or more |
| z33-14 (VA23) - z33-9 (VA24) | 24 | Power switch off | 3.0 V or more |
| z33-9 (VA24) - z33-4 (VA25) | 25 | Power switch off | 3.0 V or more |
| z33-4 (VA25) - z33-15 (VA26) | 26 | Power switch off | 3.0 V or more |
| z33-15 (VA26) - z33-10 (VA27) | 27 | Power switch off | 3.0 V or more |
| z33-10 (VA27) - z33-5 (VA28) | 28 | Power switch off | 3.0 V or more |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.
Reconnect the z33 battery smart unit connector.
Disconnect the z30 battery smart unit connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Hybrid Battery Cell | Switch Condition | Specified Condition |
|---|---|---|---|
| z30-11 (GA2) - z30-6 (VA29) | 29 | Power switch off | 3.0 V or more |
| z30-6 (VA29) - z30-1 (VA30) | 30 | Power switch off | 3.0 V or more |
| z30-1 (VA30) - z30-12 (VA31) | 31 | Power switch off | 3.0 V or more |
| z30-12 (VA31) - z30-7 (VA32) | 32 | Power switch off | 3.0 V or more |
| z30-7 (VA32) - z30-2 (VA33) | 33 | Power switch off | 3.0 V or more |
| z30-2 (VA33) - z30-13 (VA34) | 34 | Power switch off | 3.0 V or more |
| z30-13 (VA34) - z30-8 (VA35) | 35 | Power switch off | 3.0 V or more |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Hybrid Battery Cell | Switch Condition | Specified Condition |
|---|---|---|---|
| z30-8 (VA35) - z30-3 (VA36) | 36 | Power switch off | 3.0 V or more |
| z30-3 (VA36) - z30-14 (VA37) | 37 | Power switch off | 3.0 V or more |
| z30-14 (VA37) - z30-9 (VA38) | 38 | Power switch off | 3.0 V or more |
| z30-9 (VA38) - z30-4 (VA39) | 39 | Power switch off | 3.0 V or more |
| z30-4 (VA39) - z30-15 (VA40) | 40 | Power switch off | 3.0 V or more |
| z30-15 (VA40) - z30-10 (VA41) | 41 | Power switch off | 3.0 V or more |
| z30-10 (VA41) - z30-5 (VA42) | 42 | Power switch off | 3.0 V or more |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.
Reconnect the z30 battery smart unit connector.
Disconnect the z31 battery smart unit connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Hybrid Battery Cell | Switch Condition | Specified Condition |
|---|---|---|---|
| z31-13 (GA3) - z31-9 (VA43) | 43 | Power switch off | 3.0 V or more |
| z31-9 (VA43) - z31-5 (VA44) | 44 | Power switch off | 3.0 V or more |
| z31-5 (VA44) - z31-1 (VA45) | 45 | Power switch off | 3.0 V or more |
| z31-1 (VA45) - z31-14 (VA46) | 46 | Power switch off | 3.0 V or more |
| z31-14 (VA46) - z31-10 (VA47) | 47 | Power switch off | 3.0 V or more |
| z31-10 (VA47) - z31-6 (VA48) | 48 | Power switch off | 3.0 V or more |
| z31-6 (VA48) - z31-2 (VA49) | 49 | Power switch off | 3.0 V or more |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Hybrid Battery Cell | Switch Condition | Specified Condition |
|---|---|---|---|
| z31-2 (VA49) - z31-15 (VA50) | 50 | Power switch off | 3.0 V or more |
| z31-15 (VA50) - z31-11 (VA51) | 51 | Power switch off | 3.0 V or more |
| z31-11 (VA51) - z31-7 (VA52) | 52 | Power switch off | 3.0 V or more |
| z31-7 (VA52) - z31-16 (VA53) | 53 | Power switch off | 3.0 V or more |
| z31-16 (VA53) - z31-12 (VA54) | 54 | Power switch off | 3.0 V or more |
| z31-12 (VA54) - z31-8 (VA55) | 55 | Power switch off | 3.0 V or more |
| z31-8 (VA55) - z31-4 (VA56) | 56 | Power switch off | 3.0 V or more |
| *a | Rear view of wire harness connector
(to Battery Smart Unit) |
Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.
| Result | Proceed to |
|---|---|
| The difference between the highest and lowest value is less than 0.3 V and every measured value is 3.0 V or more. | A |
| Other than above. | B |
Reconnect the z31 battery smart unit connector.
Install the No. 1 hybrid battery shield sub-assembly.
A
B
Make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance.
Remove the battery smart unit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>BATTERY SMART UNIT>COMPONENTS
Measure the resistance according to the value(s) in the table below.
If the voltage of any cell of the HV battery was less than 3.0 V, measure the resistance of the battery smart unit at the terminals which relate to that battery cell.
If the difference between the highest and lowest measured cell voltage of each battery block is 0.3 V or more, measure the resistance of the battery smart unit at the terminals which relate to the cell with the lowest measured voltage.
| *a | Component without harness connected
(Battery Smart Unit) |
- | - |
| Tester Connection
(Tester Probe Polarity) |
Hybrid Battery Cell | Condition | Specified Condition |
|---|---|---|---|
| z32-13 (GA0) (-) - z32-9 (VA1) (+) | 1 | Always | 50 kΩ or higher |
| z32-9 (VA1) (-) - z32-5 (VA2) (+) | 2 | Always | 50 kΩ or higher |
| z32-5 (VA2) (-) - z32-1 (VA3) (+) | 3 | Always | 50 kΩ or higher |
| z32-1 (VA3) (-) - z32-14 (VA4) (+) | 4 | Always | 50 kΩ or higher |
| z32-14 (VA4) (-) - z32-10 (VA5) (+) | 5 | Always | 50 kΩ or higher |
| z32-10 (VA5) (-) - z32-6 (VA6) (+) | 6 | Always | 50 kΩ or higher |
| z32-6 (VA6) (-) - z32-2 (VA7) (+) | 7 | Always | 50 kΩ or higher |
| z32-13 (GA0) (-) -z32-2 (VA7) (+) | ·
1 ·
2 ·
3 ·
4 ·
5 ·
6 ·
7 |
Always | 350 kΩ or higher |
| Tester Connection
(Tester Probe Polarity) |
Hybrid Battery Cell | Condition | Specified Condition |
|---|---|---|---|
| z32-2 (VA7) (-) - z32-15 (VA8) (+) | 8 | Always | 50 kΩ or higher |
| z32-15 (VA8) (-) - z32-11 (VA9) (+) | 9 | Always | 50 kΩ or higher |
| z32-11 (VA9) (-) - z32-7 (VA10) (+) | 10 | Always | 50 kΩ or higher |
| z32-7 (VA10) (-) - z32-16 (VA11) (+) | 11 | Always | 50 kΩ or higher |
| z32-16 (VA11) (-) - z32-12 (VA12) (+) | 12 | Always | 50 kΩ or higher |
| z32-12 (VA12) (-) - z32-8 (VA13) (+) | 13 | Always | 50 kΩ or higher |
| z32-8 (VA13) (-) - z32-4 (VA14) (+) | 14 | Always | 50 kΩ or higher |
| z32-2 (VA7) (-) - z32-4 (VA14) (+) | ·
8 ·
9 ·
10 ·
11 ·
12 ·
13 ·
14 |
Always | 350 kΩ or higher |
| Tester Connection
(Tester Probe Polarity) |
Hybrid Battery Cell | Condition | Specified Condition |
|---|---|---|---|
| z33-11 (GA1) (-) - z33-6 (VA15) (+) | 15 | Always | 50 kΩ or higher |
| z33-6 (VA15) (-) - z33-1 (VA16) (+) | 16 | Always | 50 kΩ or higher |
| z33-1 (VA16) (-) - z33-12 (VA17) (+) | 17 | Always | 50 kΩ or higher |
| z33-12 (VA17) (-) - z33-7 (VA18) (+) | 18 | Always | 50 kΩ or higher |
| z33-7 (VA18) (-) - z33-2 (VA19) (+) | 19 | Always | 50 kΩ or higher |
| z33-2 (VA19) (-) - z33-13 (VA20) (+) | 20 | Always | 50 kΩ or higher |
| z33-13 (VA20) (-) - z33-8 (VA21) (+) | 21 | Always | 50 kΩ or higher |
| z33-11 (GA1) (-) - z33-8 (VA21) (+) | ·
15 ·
16 ·
17 ·
18 ·
19 ·
20 ·
21 |
Always | 350 kΩ or higher |
| Tester Connection
(Tester Probe Polarity) |
Hybrid Battery Cell | Condition | Specified Condition |
|---|---|---|---|
| z33-8 (VA21) (-) - z33-3 (VA22) (+) | 22 | Always | 50 kΩ or higher |
| z33-3 (VA22) (-) - z33-14 (VA23) (+) | 23 | Always | 50 kΩ or higher |
| z33-14 (VA23) (-) - z33-9 (VA24) (+) | 24 | Always | 50 kΩ or higher |
| z33-9 (VA24) (-) - z33-4 (VA25) (+) | 25 | Always | 50 kΩ or higher |
| z33-4 (VA25) (-) - z33-15 (VA26) (+) | 26 | Always | 50 kΩ or higher |
| z33-15 (VA26) (-) - z33-10 (VA27) (+) | 27 | Always | 50 kΩ or higher |
| z33-10 (VA27) (-) - z33-5 (VA28) (+) | 28 | Always | 50 kΩ or higher |
| z33-8 (VA21) (-) - z33-5 (VA28) (+) | ·
22 ·
23 ·
24 ·
25 ·
26 ·
27 ·
28 |
Always | 350 kΩ or higher |
| Tester Connection
(Tester Probe Polarity) |
Hybrid Battery Cell | Condition | Specified Condition |
|---|---|---|---|
| z30-11 (GA2) (-) - z30-6 (VA29) (+) | 29 | Always | 50 kΩ or higher |
| z30-6 (VA29) (-) - z30-1 (VA30) (+) | 30 | Always | 50 kΩ or higher |
| z30-1 (VA30) (-) - z30-12 (VA31) (+) | 31 | Always | 50 kΩ or higher |
| z30-12 (VA31) (-) - z30-7 (VA32) (+) | 32 | Always | 50 kΩ or higher |
| z30-7 (VA32) (-) - z30-2 (VA33) (+) | 33 | Always | 50 kΩ or higher |
| z30-2 (VA33) (-) - z30-13 (VA34) (+) | 34 | Always | 50 kΩ or higher |
| z30-13 (VA34) (-) - z30-8 (VA35) (+) | 35 | Always | 50 kΩ or higher |
| z30-11 (GA2) (-) - z30-8 (VA35) (+) | ·
29 ·
30 ·
31 ·
32 ·
33 ·
34 ·
35 |
Always | 350 kΩ or higher |
| Tester Connection
(Tester Probe Polarity) |
Hybrid Battery Cell | Condition | Specified Condition |
|---|---|---|---|
| z30-8 (VA35) (-) - z30-3 (VA36) (+) | 36 | Always | 50 kΩ or higher |
| z30-3 (VA36) (-) - z30-14 (VA37) (+) | 37 | Always | 50 kΩ or higher |
| z30-14 (VA37) (-) - z30-9 (VA38) (+) | 38 | Always | 50 kΩ or higher |
| z30-9 (VA38) (-) - z30-4 (VA39) (+) | 39 | Always | 50 kΩ or higher |
| z30-4 (VA39) (-) - z30-15 (VA40) (+) | 40 | Always | 50 kΩ or higher |
| z30-15 (VA40) (-) - z30-10 (VA41) (+) | 41 | Always | 50 kΩ or higher |
| z30-10 (VA41) (-) - z30-5 (VA42) (+) | 42 | Always | 50 kΩ or higher |
| z30-8 (VA35) (-) - z30-5 (VA42) (+) | ·
36 ·
37 ·
38 ·
39 ·
40 ·
41 ·
42 |
Always | 350 kΩ or higher |
| Tester Connection
(Tester Probe Polarity) |
Hybrid Battery Cell | Condition | Specified Condition |
|---|---|---|---|
| z31-13 (GA3) (-) - z31-9 (VA43) (+) | 43 | Always | 50 kΩ or higher |
| z31-9 (VA43) (-) - z31-5 (VA44) (+) | 44 | Always | 50 kΩ or higher |
| z31-5 (VA44) (-) - z31-1 (VA45) (+) | 45 | Always | 50 kΩ or higher |
| z31-1 (VA45) (-) - z31-14 (VA46) (+) | 46 | Always | 50 kΩ or higher |
| z31-14 (VA46) (-) - z31-10 (VA47) (+) | 47 | Always | 50 kΩ or higher |
| z31-10 (VA47) (-) - z31-6 (VA48) (+) | 48 | Always | 50 kΩ or higher |
| z31-6 (VA48) (-) - z31-2 (VA49) (+) | 49 | Always | 50 kΩ or higher |
| z31-13 (GA3) (-) - z31-2 (VA49) (+) | ·
43 ·
44 ·
45 ·
46 ·
47 ·
48 ·
49 |
Always | 350 kΩ or higher |
| Tester Connection
(Tester Probe Polarity) |
Hybrid Battery Cell | Condition | Specified Condition |
|---|---|---|---|
| z31-2 (VA49) (-) - z31-15 (VA50) (+) | 50 | Always | 50 kΩ or higher |
| z31-15 (VA50) (-) - z31-11 (VA51) (+) | 51 | Always | 50 kΩ or higher |
| z31-11 (VA51) (-) - z31-7 (VA52) (+) | 52 | Always | 50 kΩ or higher |
| z31-7 (VA52) (-) - z31-16 (VA53) (+) | 53 | Always | 50 kΩ or higher |
| z31-16 (VA53) (-) - z31-12 (VA54) (+) | 54 | Always | 50 kΩ or higher |
| z31-12 (VA54) (-) - z31-8 (VA55) (+) | 55 | Always | 50 kΩ or higher |
| z31-8 (VA55) (-) - z31-4 (VA56) (+) | 56 | Always | 50 kΩ or higher |
| z31-2 (VA49) (-) - z31-4 (VA56) (+) | ·
50 ·
51 ·
52 ·
53 ·
54 ·
55 ·
56 |
Always | 350 kΩ or higher |
Make sure to check the polarity of each terminal (positive (+) or negative (-)) before connecting a tester.
Read the resistance after the value has stabilized.
In order to avoid damaging the terminals of the battery smart unit, make sure to use tester probes with a diameter of approximately 0.5 mm (0.0197 in.) when measuring the resistance of the battery smart unit.
| Result | Proceed to |
|---|---|
| All measured values were within specified range. | A |
| Other than above. | B |
Install the battery smart unit.
A
B
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Record the output DTCs.
Make a note of the DTCs that will be used in step 10.
The DTCs will be cleared by disconnecting the cable from the negative (-) auxiliary battery terminal in steps 8 and 9.
Turn the power switch off.
NEXT
NEXT
NEXT
Check the DTCs recorded in step 7.
| Result | Proceed to |
|---|---|
| P31B3-123 is not output. | A |
| DTCs shown in P31B3-123 and Table 1 are output simultaneously. | B |
| DTCs shown in P31B3-123 and Table 1 are not output simultaneously. | C |
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A78-266, 267, 565, 586 | Drive Motor "A" Inverter Performance |
| P0A94-564, 585, 587, 589, 590 | DC/DC Converter Performance |
DTC P31B3-123 may be output simultaneously. In this case, troubleshoot the DTCs listed above first. Then, perform a reproduction test to check that no DTCs are output.
A
B
(See pageEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART)
C
Before repairing or replacing the malfunctioning part, do not perform "HV Batt Cell Low Volt READY ON Prevention Cancel".
Perform "HV Batt Cell Low Volt READY ON Prevention Cancel" (See page Engine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID BATTERY SYSTEM>UTILITY).
NEXT
NEXT
Perform a driving test for about 10 minutes to allow the ECU to store DTCs. If the hybrid system does not start, turn the power switch off and on (READY).
Because 2-trip detection logic is used, the DTC detection conditions need to be met twice.
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs.
| Result | Proceed to |
|---|---|
| P31AB-123 is not output | A |
| P31AB-123 is output | B |
| P3004-131 is output | C |