DTC C1252/52 Brake Booster Pump Motor on Time Abnormally Long |
DTC C1253/53 Pump Motor Relay Malfunction |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| C1252/52 | 311 | The pump motor is operating continuously for 178 seconds or more. (When relay malfunction is 98 seconds or more.) |
|
| C1253/53 | 321 | With the IG1 terminal voltage 9.5 V or more, the motor drive monitor remains off for 0.2 seconds or more after a motor drive on request. |
|
| ↑ | 322 | The motor drive monitor remains on for 2 seconds or more after a motor drive off request. |
|
| ↑ | 323 | The skid control ECU internal motor drive logical inconsistency continues for 2 seconds or more. | Skid control ECU (Brake booster with master cylinder assembly) |
| ↑ | 324 | An open circuit in both skid control ECU internal motor relays 1 and 2. |
|
| ↑ | 325 | An open circuit in both skid control ECU internal motor relays 1 and 3. | ↑ |
| ↑ | 326 | An open circuit in both skid control ECU internal motor relays 2 and 3. | ↑ |
| ↑ | 327 | An open circuit in skid control ECU internal motor relay 1. | ↑ |
| ↑ | 328 | An open circuit in skid control ECU internal motor relay 2. | ↑ |
| ↑ | 329 | An open circuit in skid control ECU internal motor relay 3. | ↑ |

| 1.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (ABS MOTOR RELAY) |
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Select the Active Test on the intelligent tester (Click here).
| Tester Display | Test Part | Control Range | Diagnostic Note |
| ECB* Motor Relay | ABS motor relay | Relay ON/OFF | - |
Select the Data List on the intelligent tester (Click here).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| ECB* Motor Relay | ABS motor relay / ON or OFF | ON: Relay on OFF: Relay off | - |
Check the operating condition of the ABS motor relay when operating it using the intelligent tester.
| Result | Proceed to |
| ABS motor relay in the Data List turns ON/OFF using the Active Test. | A |
| ABS motor relay in the Data List does not change using the Active Test. | B |
|
| ||||
| A | |
| 2.INSPECT BRAKE BOOSTER PUMP ASSEMBLY |
![]() |
Turn the power switch off (lock).
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
Disconnect the brake booster pump assembly connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A45-1 (BM1) - A45-2 (GND1) | Always | Below 10 Ω |
| A46-2 (BM2) - A46-1 (GND2) | Always | Below 10 Ω |
| A45-1 (BM1) - A46-2 (BM2) | Always | Below 1 Ω |
| A45-2 (GND1) - A46-1 (GND2) | Always | Below 1 Ω |
| *a | Component without harness connected (Brake Booster Pump Assembly) |
| Result | Proceed to |
| OK | A |
| NG (for LHD) | B |
| NG (for RHD) | C |
|
| ||||
|
| ||||
| A | |
| 3.CHECK HARNESS AND CONNECTOR (GND TERMINAL) |
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A45-2 (GND1) - Body ground | Always | Below 1 Ω |
| A46-1 (GND2) - Body ground | Always | Below 1 Ω |
| *a | Front view of wire harness connector (to Brake Booster Pump Assembly) |
|
| ||||
| OK | |
| 4.READ VALUE USING INTELLIGENT TESTER (ACCUMULATOR PRESSURE SENSOR) |
Reconnect the brake booster pump assembly connectors.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Select the Data List on the intelligent tester (Click here).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Accumulator Sensor | Accumulator pressure sensor / Min.: 0.00 V, Max.: 5.00 V | Specified value: 2.90 to 4.20 V | When brake fluid is stored in the accumulator: Accumulator pressure changes in accordance with volume of fluid stored in the accumulator |
Wait for 30 seconds without depressing the brake pedal.
Check that the accumulator pressure sensor output value change is within the specified range.
|
| ||||
| OK | |
| 5.RECONFIRM DTC |
Turn the power switch off (lock).
Clear the DTCs (Click here).
Turn the power switch on (IG).
Check if the same DTC is output (Click here).
| Result | Proceed to |
| DTCs C1252/52 and C1253/53 are not output. | A |
| DTCs C1252/52 and/or C1253/53 are output (for LHD). | B |
| DTCs C1252/52 and/or C1253/53 are output (for RHD). | C |
|
| ||||
|
| ||||
| A | ||
| ||
| 6.CHECK HARNESS AND CONNECTOR (MRI TERMINAL) |
![]() |
Turn the power switch off (lock).
Check that the ABS MTR NO. 1 (30 A) and ABS MTR NO. 2 (30 A) fuses are normal.
Make sure that there is no looseness at the locking part and the connecting part of the connector.
Disconnect the skid control ECU (brake booster with master cylinder assembly) connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A41-1 (MRI1) - Body ground | Always | 11 to 14 V |
| A41-2 (MRI2) - Body ground | Always | 11 to 14 V |
| *a | Front view of wire harness connector (to Skid Control ECU (Brake Booster with Master Cylinder Assembly)) |
|
| ||||
| OK | |
| 7.CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - BRAKE BOOSTER PUMP ASSEMBLY) |
Make sure that there is no looseness at the locking part and the connecting part of the connectors.
Disconnect the brake booster pump assembly connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| A41-29 (MRO1) - A45-1 (BM1) | Always | Below 1 Ω |
| A41-29 (MRO1) - Body ground | Always | 10 kΩ or higher |
| A41-30 (MRO2) - A46-2 (BM2) | Always | Below 1 Ω |
| A41-30 (MRO2) - Body ground | Always | 10 kΩ or higher |
| Result | Proceed to |
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG | C |
|
| ||||
|
| ||||
| A | ||
| ||
| 8.PERFORM ACTIVE TEST USING INTELLIGENT TESTER (SOLENOID VALVE) |
Select the Active Test on the intelligent tester (Click here).
| Tester Display | Test Part | Control Range | Diagnostic Note |
| ECB* Solenoid (SMC/SRC/SCC) | Switching solenoid valve (SMC/SRC/SCC) | Solenoid ON/OFF | Operation sound of solenoid (clicking sound) can be heard |
Perform the Active Test of the solenoid using the intelligent tester.
Select the Data List on the intelligent tester (Click here).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Wheel Cylinder Pressure Sensor | Wheel cylinder pressure sensor / Min.: 0.00 V, Max.: 5.00 V | When brake pedal released: 0.10 to 0.90 V | Reading increases when brake pedal is depressed |
Check that the output value of the wheel cylinder pressure sensor does not increase.
| Result | Proceed to |
| OK (for LHD) | A |
| OK (for RHD) | B |
| NG (for LHD) | C |
| NG (for RHD) | D |
|
| ||||
|
| ||||
|
| ||||
| A | ||
| ||