The occupant detection sensor (separate type front seat cushion pad (front passenger seat)) detects if the passenger seat is occupied and sends signals to the combination meter assembly. The front seat inner belt assembly (front passenger seat) detects the passenger seat belt condition and sends signals to the combination meter assembly. After receiving the signals from the occupant detection sensor (separate type front seat cushion pad (front passenger seat)) and front seat inner belt assembly (front passenger seat), the seat belt warning light on the combination meter assembly will blink or go off.
The seat belt warning light on the combination meter assembly is used for both the driver seat and front passenger seat.Check that the operation of the seat belt warning light is normal first.
If the seat belt warning light does not operate for both the driver seat and front passenger seat, replace the meter circuit plate.
Click hereVehicle Interior>METER / GAUGE / DISPLAY>COMBINATION METER>REMOVAL
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Combination Meter / Data List.
Read the Data List according to the display on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| P-Seatbelt Buckle SW | Front passenger seat belt buckle switch signal | ON or OFF | ON: Front passenger seat belt fastened
OFF: Front passenger seat belt not fastened |
- |
| Passenger Occupant Detection Switch | Occupant detection sensor signal | ON or OFF | ON: Front passenger seat occupied
OFF: Front passenger seat not occupied |
- |
| Tester Display |
|---|
| P-Seatbelt Buckle SW |
| Passenger Occupant Detection Switch |
The GTS display changes correctly in response to the front passenger seat belt and front passenger seat condition.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (P-Seatbelt Buckle SW) | B |
| NG (Passenger Occupant Detection Switch) | C |
A
B
C
Remove the front seat inner belt assembly (front passenger seat).
Click hereVehicle Interior>SEAT BELT>FRONT SEAT INNER BELT ASSEMBLY>REMOVAL
Inspect the front seat inner belt assembly (front passenger seat) (seat belt warning switch).
Click hereVehicle Interior>SEAT BELT>FRONT SEAT INNER BELT ASSEMBLY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F6 meter circuit plate connector.
Disconnect the M67*1 or M71*2 front seat inner belt assembly (front passenger seat) connector.
*1: for LHD
*2: for RHD
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-14 (PBKL) - M67-3 (+) | Always | Below 1 Ω |
| F6-14 (PBKL) or M67-3 (+) - Body ground | Always | 10 kΩ or higher |
| M67-2 (E) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-14 (PBKL) - M71-3 (+) | Always | Below 1 Ω |
| F6-14 (PBKL) or M71-3 (+) - Body ground | Always | 10 kΩ or higher |
| M71-2 (E) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the front seat inner belt assembly (front passenger seat).
Click hereVehicle Interior>SEAT BELT>FRONT SEAT INNER BELT ASSEMBLY>REMOVAL
Inspect the front seat inner belt assembly (front passenger seat) (occupant detection sensor line).
Click hereVehicle Interior>SEAT BELT>FRONT SEAT INNER BELT ASSEMBLY>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Remove the occupant detection sensor (separate type front seat cushion pad (front passenger seat)).
Click hereVehicle Interior>SEAT BELT>OCCUPANT DETECTION SENSOR>REMOVAL
Inspect the occupant detection sensor (separate type front seat cushion pad (front passenger seat)).
Click hereVehicle Interior>SEAT BELT>OCCUPANT DETECTION SENSOR>INSPECTION
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Disconnect the F6 meter circuit plate connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-13 (PODS) - M67-5 (+) | Always | Below 1 Ω |
| F6-13 (PODS) or M67-5 (+) - Body ground | Always | 10 kΩ or higher |
| M67-4 (E) - Body ground | Always | Below 1 Ω |
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| F6-13 (PODS) - M71-5 (+) | Always | Below 1 Ω |
| F6-13 (PODS) or M71-5 (+) - Body ground | Always | 10 kΩ or higher |
| M71-4 (E) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
OK
NG