AUTO LSD Indicator Light Remains ON
Circuit diagnosis · Vehicles built from Aug 2008
DESCRIPTION
The AUTO LSD is a system for 2WD vehicles. When the VSC OFF switch is pushed on, the AUTO LSD function is available and the AUTO LSD indicator light illuminates.- HINT:
- The AUTO LSD does not operate even if the VSC OFF switch is pressed under the following conditions:
- The TRC or VSC system is faulty.
- The temperature inside the brake actuator assembly increases and the AUTO LSD operation is suspended.
- The TRC or VSC system is faulty.
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- When replacing the brake actuator assembly, perform zero point calibration (Click here).
| 1. CHECK CAN COMMUNICATION SYSTEM |
Check if a CAN communication system DTC is output (Click here).
- Result:
Result
Proceed to
DTC is not output.
A
DTC is output.
B
- OK:
- The connector is securely connected.
|
|
||||
| A | |
| 2. CHECK SKID CONTROL ECU CONNECTOR |
Check if the skid control ECU connector is securely connected.
- OK:
- The connector is securely connected.
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (SKID CONTROL ECU - BODY GROUND) |
Disconnect the skid control ECU connector.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
A67-30 (CSW) - Body ground
VSC OFF switch is not pushed
10 kΩ or higher
VSC OFF switch is pushed
Below 1Ω
|
|
||||
| NG | |
| 4. INSPECT TRACTION CONTROL SWITCH (VSC OFF SWITCH) |
Remove the VSC OFF switch (Click here).

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Switch Condition
Specified Condition
6 (E) - 9 (+)
Not pushed
10 kΩ or higher
Pushed
Below 1Ω
|
|
||||
| OK | |
| 5. CHECK HARNESS AND CONNECTOR (VSC OFF SWITCH - SKID CONTROL ECU/BODY GROUND) |
![]() ![]() |
Disconnect the skid control ECU connector.
Disconnect the VSC OFF switch connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A67-30 (CSW) - E96-9 (+)
Always
Below 1 Ω
A67-30 (CSW) - Body ground
Always
10 kΩ or higher
E96-6 (E) - Body ground
Always
Below 1 Ω
|
|
||||
| OK | |
| 6. INSPECT COMBINATION METER ASSEMBLY |
Inspect the combination meter (Click here).
|
|
||||
| OK | ||
| ||