Home
›
Power Source / Network
›
3ZR-FAE BATTERY / CHARGING
›
CHARGING SYSTEM
›
from 2015.04
RM3090E
_57
Power Source / Network
_008394
3ZR-FAE BATTERY / CHARGING
_0046852
CHARGING SYSTEM
S
3ZR-FAE BATTERY / CHARGING CHARGING SYSTEM DIAGNOSTIC TROUBLE CODE CHART
Charging System
DTC No.
Detection Item
Warning Indicate
Memory
Link
P058A
Battery Monitor Module Performance
Not displayed
DTC stored
P1602
Deterioration of Battery
Not displayed
DTC stored
P161A
Lost Communication with Alternator
Displayed
DTC stored
P162B
Lost Communication with Battery Monitor Module
Not displayed
DTC stored