The ECM constantly generates a 5 V power source voltage from the battery voltage supplied to the +B (BATT) terminal to operate the microprocessor. The ECM also provides this power source voltage to the sensors through the VC output circuit.
When the VC circuit is short-circuited, the microprocessor in the ECM and the sensors that are supplied with power through the VC circuit are inactivated because power is not supplied from the VC circuit. Under this condition, the system does not start up and the MIL does not illuminate even if the system malfunctions.
Under normal conditions, the MIL is illuminated for several seconds when the engine switch is turned on (IG). The MIL goes off when the engine is started.
Check that the Malfunction Indicator Lamp (MIL) lights up when the engine switch is turned on (IG).
MIL lights up.
| Proceed to |
|---|
| OK |
| NG |
OK
NG
Connect the GTS to the DLC3.
Turn the engine switch on (IG).
Turn the GTS on.
Check the communication between the GTS and ECM.
| Result | Proceed to |
|---|---|
| Communication is not possible | A |
| Communication is possible | B |
A
B
Click hereEngine / Hybrid System>2AR-FE ENGINE CONTROL>SFI SYSTEM(w/ Canister Pump Module)>MIL Circuit
Disconnect the throttle with motor body assembly connector.
Turn the engine switch on (IG).
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
Perform "Inspection After Repair" after replacing the throttle with motor body assembly.
Click hereEngine / Hybrid System>2AR-FE ENGINE CONTROL>SFI SYSTEM(w/ Canister Pump Module)>INITIALIZATION
A
B
Disconnect the accelerator pedal sensor assembly connector.
Turn the engine switch on (IG).
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Disconnect the canister pump module connector.
Turn the engine switch on (IG).
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Disconnect the intake air control valve actuator (for tumble control valve) connector.
Turn the engine switch on (IG).
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Click hereEngine / Hybrid System>2AR-FE INTAKE / EXHAUST>INTAKE AIR CONTROL VALVE ACTUATOR(for TCV)>REMOVAL
Disconnect the camshaft position sensor (for intake camshaft) connector.
Turn the engine switch on (IG).
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Disconnect the camshaft position sensor (for exhaust camshaft) connector.
Turn the engine switch on (IG).
Check the MIL.
| Result | Proceed to |
|---|---|
| MIL does not illuminate | A |
| MIL illuminates | B |
A
B
Disconnect the throttle with motor body assembly connector.
Disconnect the accelerator pedal sensor assembly connector.
Disconnect the canister pump module connector.
Disconnect the intake air control valve actuator (for tumble control valve) connector.
Disconnect the camshaft position sensor (for intake camshaft) connector.
Disconnect the camshaft position sensor (for exhaust camshaft) connector.
Disconnect the ECM connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| B77-125 (VCTA) - Body ground | Always | 10 kΩ or higher |
| A62-53 (VCPA) - Body ground | Always | 10 kΩ or higher |
| A62-56 (VCP2) - Body ground | Always | 10 kΩ or higher |
| B77-130 (VCIA) - Body ground | Always | 10 kΩ or higher |
| A62-34 (VCPP) - Body ground | Always | 10 kΩ or higher |
| B77-111 (VCE1) - Body ground | Always | 10 kΩ or higher |
| B77-113 (VCV1) - Body ground | Always | 10 kΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
OK
NG