HEATING / AIR CONDITIONING  COMBUSTION TYPE POWER HEATER SYSTEM  Power Heater Alternator Circuit  


DESCRIPTION

The heater assembly receives engine operation signals from the battery current sensor assembly*1 or generator assembly*2. If this circuit is open, the heater assembly will determine that the engine operation signals indicate on. If this circuit is shorted, the heater assembly will determine that the engine operation signals indicate off and the heater assembly will not operate.

*1: w/ Stop and Start System

*2: w/o Stop and Start System


WIRING DIAGRAM

E267501E02
5.375,1.604 5.833,1.802 0.458,0.198 10 false A33 5.375,1.76 6.656,2.115 1.281,0.354 10 false Heater Assembly 5.531,0.813 5.99,1.01 0.458,0.198 10 false + 5.333,0.708 5.458,0.896 0.125,0.188 10 false 8 2.542,0.802 2.927,0.958 0.385,0.156 10 false ALTL 2.99,0.698 3.344,0.854 0.354,0.156 10 false 8 1.781,1.271 2.167,1.427 0.385,0.156 10 false A58 1.781,1.438 4.354,1.635 2.573,0.198 10 false Battery Current Sensor Assembly 2.052,2.583 2.438,2.74 0.385,0.156 10 false B61 2.052,2.76 4.323,2.958 2.271,0.198 10 false Generator Assembly 2.792,2.125 2.896,2.292 0.104,0.167 10 false L 2.948,2 3.302,2.156 0.354,0.156 10 false 4 0.063,3.01 2.333,3.208 2.271,0.198 10 false *2: except 2WW 0.063,2.688 2.333,2.885 2.271,0.198 10 false *1: for 2WW 0.656,3.333 2.927,3.531 2.271,0.198 10 false : LIN Communication Line 0.573,1.281 1.354,1.698 0.781,0.417 10 false Generator Assembly 4.563,0.708 4.781,0.906 0.219,0.198 10 false *1 4.594,2 4.813,2.198 0.219,0.198 10 false *2

CAUTION / NOTICE / HINT

NOTICE:

First, confirm that there are no malfunctions in the LIN communication systems. Refer to the how to proceed with troubleshooting procedure.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>COMBUSTION TYPE POWER HEATER SYSTEM>PROBLEM SYMPTOMS TABLE


PROCEDURE

1.INSPECT GENERATOR ASSEMBLY

OK (for 2WW)

2.CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - GENERATOR CONTROL ECU ASSEMBLY)

OK (except 2WW)

3.CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - GENERATOR ASSEMBLY)

NG

2.CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - GENERATOR CONTROL ECU ASSEMBLY)
a.
E267497C02
1.5,0.208 1.896,0.448 0.396,0.24 1.99,1.521 2.354,1.771 2.354,1.771 2.583,1.771 true 1.563,0.26 2.021,0.458 0.458,0.198 10 A33 0.052,0.052 0.51,0.25 0.458,0.198 10 *a 2.656,1.677 2.865,1.885 0.208,0.208 10 +
*a Front view of wire harness connector
(to Heater Assembly)


Disconnect the heater assembly connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A33-8 (+) - Body ground Engine is running (Generator assembly operate) 11 to 14 V



Result:
Proceed to
OK
NG



OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

NG

4.CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - BATTERY CURRENT SENSOR ASSEMBLY)
3.CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - GENERATOR ASSEMBLY)
a.
E267497C02
1.5,0.208 1.896,0.448 0.396,0.24 1.99,1.521 2.354,1.771 2.354,1.771 2.583,1.771 true 1.563,0.26 2.021,0.458 0.458,0.198 10 A33 0.052,0.052 0.51,0.25 0.458,0.198 10 *a 2.656,1.677 2.865,1.885 0.208,0.208 10 +
*a Front view of wire harness connector
(to Heater Assembly)


Disconnect the heater assembly connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition
A33-8 (+) - Body ground Engine is running (Generator assembly operate) 11 to 14 V



Result:
Proceed to
OK
NG



OK

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE

NG

5.CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - GENERATOR ASSEMBLY)
4.CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - BATTERY CURRENT SENSOR ASSEMBLY)
a.

Disconnect the A33 heater assembly connector.


b.

Disconnect the A58 battery current sensor assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A33-8 (+) - A58-8 (ALTL) Always Below 1 Ω
A33-8 (+) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.CHECK HARNESS AND CONNECTOR (HEATER ASSEMBLY - GENERATOR ASSEMBLY)
a.

Disconnect the A33 heater assembly connector.


b.

Disconnect the B61 generator assembly connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
A33-8 (+) - B61-4 (L) Always Below 1 Ω
A33-8 (+) - Body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR