CHECK POSITION CONTROL ECU ASSEMBLY (DRIVER SEAT)
| *A | for LHD | *B | for RHD |
for LHD
Disconnect the T7 and T8 position control ECU assembly (driver seat) connectors.
Measure the voltage and resistance according to the value(s) in the table below.
Measure the values on the wire harness side with the connector disconnected.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| T7-2 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| T7-3 (+B) - Body ground | W - Body ground | Battery power supply | Power switch off | 11 to 14 V |
| T8-1 (IG) - Body ground | P - Body ground | Ignition power supply | Power switch off | Below 1 V |
| Power switch on (IG) | 11 to 14 V | |||
| T8-15 (SYSB) - Body ground | G - Body ground | System power source | Power switch off | 11 to 14 V |
Reconnect the T7 and T8 position control ECU assembly (driver seat) connectors.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| T7-1 (SLD+) - Body ground | L - Body ground | Slide motor signal (forward) | Slide switch off | Below 1 V |
| Slide switch on (Forward) | 11 to 14 V | |||
| T7-5 (SLD-) - Body ground | GR - Body ground | Slide motor signal (rearward) | Slide switch off | Below 1 V |
| Slide switch on (Rearward) | 11 to 14 V | |||
| T7-6 (LFT+) - Body ground | V - Body ground | Rear lifter motor signal (upward) | Rear lifter switch off | Below 1 V |
| Rear lifter switch on (Upward) | 11 to 14 V | |||
| T7-7 (FRV+) - Body ground | B - Body ground | Front vertical motor signal (upward) | Front vertical switch off | Below 1 V |
| Front vertical switch on (Upward) | 11 to 14 V | |||
| T7-9 (L+) - Body ground | V - Body ground | Lumbar support adjuster motor signal (forward) | Lumbar support adjuster switch off | Below 1 V |
| Lumbar support adjuster switch on (Forward) | 11 to 14 V | |||
| T7-10 (RCL+) - Body ground | P - Body ground | Reclining motor signal (forward) | Reclining switch off | Below 1 V |
| Reclining switch on (Forward) | 11 to 14 V | |||
| T6-3 (L-) - Body ground | L - Body ground | Lumbar support adjuster motor signal (rearward) | Lumbar support adjuster switch off | Below 1 V |
| Lumbar support adjuster switch on (Rearward) | 11 to 14 V | |||
| T6-4 (FRV-) - Body ground | R - Body ground | Front vertical motor signal (downward) | Front vertical switch off | Below 1 V |
| Front vertical switch on (Downward) | 11 to 14 V | |||
| T6-5 (LFT-) - Body ground | G - Body ground | Lifter motor signal (downward) | Rear lifter switch off | Below 1 V |
| Rear lifter switch on (Downward) | 11 to 14 V | |||
| T6-6 (RCL-) - Body ground | LG - Body ground | Reclining motor signal (rearward) | Reclining switch off | Below 1 V |
| Reclining switch on (Rearward) | 11 to 14 V | |||
| T8-4 (LFLF) - Body ground | W - Body ground | Lumbar support adjuster switch (forward) signal | Lumbar support adjuster switch off | 11 to 14 V |
| Lumbar support adjuster switch on (Forward) | Below 1 V | |||
| T8-6 (FRVU) - Body ground | L - Body ground | Front vertical switch (upward) signal | Front vertical switch off | 11 to 14 V |
| Front vertical switch on (Upward) | Below 1 V | |||
| T8-7 (LFTU) - Body ground | BR - Body ground | Rear lifter switch (upward) signal | Rear lifter switch off | 11 to 14 V |
| Rear lifter switch on (Upward) | Below 1 V | |||
| T8-8 (RCLF) - Body ground | R - Body ground | Reclining switch (forward) signal | Reclining switch off | 11 to 14 V |
| Reclining switch on (Forward) | Below 1 V | |||
| T8-9 (SLDF) - Body ground | B - Body ground | Slide switch (forward) signal | Slide switch off | 11 to 14 V |
| Slide switch on (Forward) | Below 1 V | |||
| T8-12 (SGND) - Body ground | BR - Body ground | Sensor ground | Always | Below 1 Ω |
| T8-18 (LFLR) - Body ground | L - Body ground | Lumbar support adjuster switch (rearward) signal | Lumbar support adjuster switch off | 11 to 14 V |
| Lumbar support adjuster switch on (Rearward) | Below 1 Ω | |||
| T8-20 (FRVD) - Body ground | V - Body ground | Front vertical switch (downward) signal | Front vertical switch off | 11 to 14 V |
| Front vertical switch on (Downward) | Below 1 V | |||
| T8-21 (LFTD) - Body ground | LG - Body ground | Rear lifter switch (downward) signal | Rear lifter switch off | 11 to 14 V |
| Rear lifter switch on (Downward) | Below 1 V | |||
| T8-22 (RCLR) - Body ground | G - Body ground | Reclining switch (rearward) signal | Reclining switch off | 11 to 14 V |
| Reclining switch on (Rearward) | Below 1 V | |||
| T8-23 (SLDR) - Body ground | GR - Body ground | Slide switch (rearward) signal | Slide switch off | 11 to 14 V |
| Slide switch on (Rearward) | Below 1 V |
Check for pulses according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| T8-10 (SSFV) - Body ground | L - Body ground | Front vertical position signal | Front vertical function operating | Pulse generation |
| T8-11 (SSRR) - Body ground | V - Body ground | Reclining position signal | Reclining function operating | Pulse generation |
| T8-25 (SSRL) - Body ground | B - Body ground | Rear lifter position signal | Rear lifter function operating | Pulse generation |
| T8-26 (SSRS) - Body ground | G - Body ground | Slide position signal | Slide function operating | Pulse generation |
for RHD
Disconnect the S7 and S8 position control ECU assembly (driver seat) connectors.
Measure the voltage and resistance according to the value(s) in the table below.
Measure the values on the wire harness side with the connector disconnected.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| S7-2 (GND) - Body ground | W-B - Body ground | Ground | Always | Below 1 Ω |
| S7-3 (+B) - Body ground | W - Body ground | Battery power supply | Power switch off | 11 to 14 V |
| S8-1 (IG) - Body ground | P - Body ground | Ignition power supply | Power switch off | Below 1 V |
| Power switch on (IG) | 11 to 14 V | |||
| S8-15 (SYSB) - Body ground | G - Body ground | System power source | Power switch off | 11 to 14 V |
Reconnect the S7 and S8 position control ECU assembly (driver seat) connectors.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| S7-1 (SLD+) - Body ground | L - Body ground | Slide motor signal (forward) | Slide switch off | Below 1 V |
| Slide switch on (Forward) | 11 to 14 V | |||
| S7-5 (SLD-) - Body ground | GR - Body ground | Slide motor signal (rearward) | Slide switch off | Below 1 V |
| Slide switch on (Rearward) | 11 to 14 V | |||
| S7-6 (LFT+) - Body ground | V - Body ground | Rear lifter motor signal (upward) | Rear lifter switch off | Below 1 V |
| Rear lifter switch on (Upward) | 11 to 14 V | |||
| S7-7 (FRV+) - Body ground | B - Body ground | Front vertical motor signal (upward) | Front vertical switch off | Below 1 V |
| Front vertical switch on (Upward) | 11 to 14 V | |||
| S7-9 (L+) - Body ground | V - Body ground | Lumbar support adjuster motor signal (forward) | Lumbar support adjuster switch off | Below 1 V |
| Lumbar support adjuster switch on (Forward) | 11 to 14 V | |||
| S7-10 (RCL+) - Body ground | P - Body ground | Reclining motor signal (forward) | Reclining switch off | Below 1 V |
| Reclining switch on (Forward) | 11 to 14 V | |||
| S6-3 (L-) - Body ground | L - Body ground | Lumbar support adjuster motor signal (rearward) | Lumbar support adjuster switch off | Below 1 V |
| Lumbar support adjuster switch on (Rearward) | 11 to 14 V | |||
| S6-4 (FRV-) - Body ground | R - Body ground | Front vertical motor signal (downward) | Front vertical switch off | Below 1 V |
| Front vertical switch on (Downward) | 11 to 14 V | |||
| S6-5 (LFT-) - Body ground | G - Body ground | Lifter motor signal (downward) | Rear lifter switch off | Below 1 V |
| Rear lifter switch on (Downward) | 11 to 14 V | |||
| S6-6 (RCL-) - Body ground | LG - Body ground | Reclining motor signal (rearward) | Reclining switch off | Below 1 V |
| Reclining switch on (Rearward) | 11 to 14 V | |||
| S8-4 (LFLF) - Body ground | W - Body ground | Lumbar support adjuster switch (forward) signal | Lumbar support adjuster switch off | 11 to 14 V |
| Lumbar support adjuster switch on (Forward) | Below 1 V | |||
| S8-6 (FRVU) - Body ground | L - Body ground | Front vertical switch (upward) signal | Front vertical switch off | 11 to 14 V |
| Front vertical switch on (Upward) | Below 1 V | |||
| S8-7 (LFTU) - Body ground | BR - Body ground | Rear lifter switch (upward) signal | Rear lifter switch off | 11 to 14 V |
| Rear lifter switch on (Upward) | Below 1 V | |||
| S8-8 (RCLF) - Body ground | R - Body ground | Reclining switch (forward) signal | Reclining switch off | 11 to 14 V |
| Reclining switch on (Forward) | Below 1 V | |||
| S8-9 (SLDF) - Body ground | B - Body ground | Slide switch (forward) signal | Slide switch off | 11 to 14 V |
| Slide switch on (Forward) | Below 1 V | |||
| S8-12 (SGND) - Body ground | BR - Body ground | Sensor ground | Always | Below 1 Ω |
| S8-18 (LFLR) - Body ground | L - Body ground | Lumbar support adjuster switch (rearward) signal | Lumbar support adjuster switch off | 11 to 14 V |
| Lumbar support adjuster switch on (Rearward) | Below 1 Ω | |||
| S8-20 (FRVD) - Body ground | V - Body ground | Front vertical switch (downward) signal | Front vertical switch off | 11 to 14 V |
| Front vertical switch on (Downward) | Below 1 V | |||
| S8-21 (LFTD) - Body ground | LG - Body ground | Rear lifter switch (downward) signal | Rear lifter switch off | 11 to 14 V |
| Rear lifter switch on (Downward) | Below 1 V | |||
| S8-22 (RCLR) - Body ground | G - Body ground | Reclining switch (rearward) signal | Reclining switch off | 11 to 14 V |
| Reclining switch on (Rearward) | Below 1 V | |||
| S8-23 (SLDR) - Body ground | GR - Body ground | Slide switch (rearward) signal | Slide switch off | 11 to 14 V |
| Slide switch on (Rearward) | Below 1 V |
Check for pulses according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| S8-10 (SSFV) - Body ground | L - Body ground | Front vertical position signal | Front vertical function operating | Pulse generation |
| S8-11 (SSRR) - Body ground | V - Body ground | Reclining position signal | Reclining function operating | Pulse generation |
| S8-25 (SSRL) - Body ground | B - Body ground | Rear lifter position signal | Rear lifter function operating | Pulse generation |
| S8-26 (SSRS) - Body ground | G - Body ground | Slide position signal | Slide function operating | Pulse generation |
CHECK MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) AND INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
| *1 | Main Body ECU (Multiplex Network Body ECU) | - | - |
Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>REMOVAL
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>REMOVAL
Connect the instrument panel junction block assembly connectors.
Measure the voltage and resistance according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| A-32 (IG) - Body ground | None - Body ground | Ignition power supply | Power switch on (IG) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| A-31 (BECU) - Body ground | None - Body ground | Battery power supply | Power switch off | 11 to 14 V |
| A-30 (ACC) - Body ground | None - Body ground | ACC power supply | Power switch on (ACC) | 11 to 14 V |
| Power switch off | Below 1 V | |||
| A-11 (GND1) - Body ground | None - Body ground | Ground | Always | Below 1 Ω |
Install the main body ECU (multiplex network body ECU).
for LHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for LHD)>INSTALLATION
for RHD: Click herePower Source / Network>POWER DISTRIBUTION>MAIN BODY ECU (for RHD)>INSTALLATION
Measure the voltage according to the value(s) in the table below.
| Terminal No. (Symbol) | Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| G44-1 (FLCY) - Body ground*1 | R - Body ground | Front door courtesy light switch assembly (driver door) input | Front door (driver door) open | Below 1 V |
| Front door (driver door) closed | 4.7 to 5.3 V | |||
| G44-6 (FRCY) - Body ground*2 | BE - Body ground | Front door courtesy light switch assembly (driver door) input | Front door (driver door) open | Below 1 V |
| Front door (driver door) closed | 4.7 to 5.3 V | |||
| G43-7 (MM) - Body ground | L - Body ground | SET switch signal for seat memory switch (driver door) | SET switch on | Below 1 V |
| SET switch off | 11 to 14 V | |||
| G43-9 (M2) - Body ground | R - Body ground*1
BR - Body ground*2 |
M2 switch signal for seat memory switch (driver door) | M2 switch on | Below 1 V |
| M2 switch off | 11 to 14 V | |||
| G43-10 (M1) - Body ground | GR - Body ground | M1 switch signal for seat memory switch (driver door) | M1 switch on | Below 1 V |
| M1 switch off | 11 to 14 V |
*1: for LHD
*2: for RHD