| B1411
|
Room Temperature Sensor Circuit
|
·
Diagnosis condition: Ambient temperature is -30°C (-22°F) or more
·
Malfunction status: Open or short in room temperature sensor circuit
·
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)
|
|
| B1412
|
Ambient Temperature Sensor Circuit
|
·
Diagnosis condition: None
·
Malfunction status: Open or short in ambient temperature sensor circuit
·
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)
|
|
| B1413
|
Evaporator Temperature Sensor Circuit
|
·
Diagnosis condition: None
·
Malfunction status: Open or short in evaporator temperature sensor circuit
·
Detection time: None (Present malfunction), continuously for 4 seconds or more (Past malfunction)
|
|
| B1423
|
Pressure Sensor Circuit
|
·
Diagnosis condition: Power switch on (IG)
·
Malfunction Status: Refrigerant pressure signal malfunction
·
Detection time: Continuously for 4 seconds or more (Present malfunction)
|
|
| B1441
|
Air Mix Damper Control Servo Motor Circuit (Passenger Side)
|
·
Diagnosis condition: During No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) operation
·
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
·
Detection time: Continuously for 30 seconds or more
|
|
| B1442
|
Air Inlet Damper Control Servo Motor Circuit
|
·
Diagnosis condition: During No. 1 blower damper servo sub-assembly operation
·
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
·
Detection time: Continuously for 30 seconds or more
|
|
| B1443
|
Air Outlet Damper Control Servo Motor Circuit
|
·
Diagnosis condition: During No. 1 air conditioning radiator damper servo sub-assembly (driver side mode) operation
·
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
·
Detection time: Continuously for 30 seconds or more
|
|
| B1446
|
Air Mix Damper Control Servo Motor Circuit (Driver Side)
|
·
Diagnosis condition: During No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) operation
·
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
·
Detection time: Continuously for 30 seconds or more
|
|
| B1448
|
Passenger Side FACE Servo Motor Circuit
|
·
Diagnosis condition: During No. 3 air conditioning radiator damper servo sub-assembly (front passenger side mode) operation
·
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
·
Detection time: Continuously for 30 seconds or more
|
|
| B1449
|
Air Outlet Damper Control Servo Motor Circuit (Rear)
|
·
Diagnosis condition: During No. 2 air conditioning radiator damper servo sub-assembly (rear mode) operation
·
Malfunction status: The damper servo operation request signal is output but the position information of the servo does not change or servo is malfunctioning
·
Detection time: Continuously for 30 seconds or more
|
|
| B1471
|
A/C Inverter High Voltage Power Resource System Malfunction
|
·
Diagnosis condition: Power switch on (READY)
·
Malfunction status: Open or short in A/C inverter high voltage power resource system
|
|
| B1472
|
A/C Inverter High Voltage Output System Malfunction
|
·
Diagnosis condition: Compressor operation
·
Malfunction status: Open or short in A/C inverter high voltage output system
|
|
| B1474
|
A/C Inverter Malfunction
|
·
Diagnosis condition: Power switch on (READY)
·
Malfunction status: The inverter internal temperature is outside the specified range (exceeds the maximum)
|
|
| B1475
|
A/C Inverter Cooling / Heating System Malfunction
|
·
Diagnosis condition: Power switch on (READY)
·
Malfunction status: Outside base temperature in the inverter (unreasonable temperature)
|
|
| B1476
|
A/C Inverter Load System Malfunction
|
·
Diagnosis condition: Compressor operation request
·
Malfunction status: Motor rotation load while the compressor is operating is too large or too small
|
|
| B1497
|
Communication Malfunction (Bus Ic)
|
·
Diagnosis condition: None
·
Malfunction status: Error or open in communication line between air conditioning amplifier assembly and servo motor
|
|
| B1498
|
Communication Malfunction (A/C Inverter Local)
|
·
Diagnosis condition: Power switch on (READY)
·
Malfunction status: Error or open in communication line between the hybrid vehicle control ECU assembly and compressor with motor assembly or high-voltage power source shut off
|
|
| B14A8
|
Glass Temperature Sensor Circuit
|
·
Diagnosis condition: Power switch on (IG)
·
Malfunction status: Communication between rain sensor (glass humidity sensor) and main body ECU (multiplex network body ECU) is abnormal or stops
·
Detection time: After power switch is turned on (IG) and 10 seconds elapse, continuously for 5 seconds or more
|
|
| B14A9
|
Glass Surroundings Temperature Sensor Circuit
|
·
Diagnosis condition: Power switch on (IG)
·
Malfunction status: Communication between rain sensor (glass humidity sensor) and main body ECU (multiplex network body ECU) is abnormal or stops
·
Detection time: After power switch is turned on (IG) and 10 seconds elapse, continuously for 5 seconds or more
|
|
| B14AA
|
Glass Humidity Sensor Circuit
|
·
Diagnosis condition: Power switch on (IG)
·
Malfunction status: Communication between rain sensor (glass humidity sensor) and main body ECU (multiplex network body ECU) is abnormal or stops
·
Detection time: After power switch is turned on (IG) and 10 seconds elapse, continuously for 5 seconds or more
|
|
| B14B2
|
Lost Communication with Front Panel LIN
|
Lost communication with air conditioning control assembly
·
Diagnosis condition: Power switch on (IG)
·
Malfunction status: Lost communication with air conditioning control assembly
·
Detection time: Continuously for 10 seconds or more
|
|
| B14B8
|
Refrigerant Shortage
|
·
Diagnosis condition: The amount of refrigerant is judged to be insufficient in normal operation
·
Malfunction status: When following condition is detected in refrigerant shortage check in normal operation; Amount of refrigerant is insufficient
·
Detection time: During air conditioning system operation for 10 minutes or more
|
|
| P1C7C49
|
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
|
High voltage system insulation malfunction
|
|
| U0100
|
Lost Communication with ECM / PCM "A"
|
No communication with ECM
|
|
| U0131
|
Lost Communication with Power Steering Control Module
|
No communication with rack and pinion power steering gear assembly (power steering ECU assembly)
|
|
| U0142
|
Lost Communication with Body Control Module "B"
|
No communication with main body ECU (multiplex network body ECU)
|
|
| U0151
|
Lost Communication with Restraints Control Module
|
No communication with airbag sensor assembly
|
|
| U0155
|
Lost Communication with Instrument Panel Cluster (IPC) Control Module
|
No communication with combination meter assembly
|
|
| U0293
|
Lost Communication with HV ECU
|
No communication with hybrid vehicle control ECU assembly
|
|