HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for HV Model)  Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting)  


DESCRIPTION

If there is a difference in temperature between the left and right air outlets while dual mode is ON, the following causes are possible.

Malfunction Status Factor
There is a difference in temperature between the left and right air outlets (while cooling operation)
·

Compressor with motor assembly malfunction

·

Lack of refrigerant gas

·

Air mix damper and link operation (jamming)

·

Automatic light control sensor malfunction


There is a difference in temperature between the left and right air outlets (while heater operation)
·

Air mix damper and link operation (jamming)

·

Heater core closed waterway



WIRING DIAGRAM

E366622E13
0.229,1.021 1.802,1.396 1.573,0.375 10 false Air Conditioning Amplifier Assembly 1.844,3.865 3.208,4.021 1.365,0.156 10 false H1 1.854,4.021 4.073,4.219 2.219,0.198 10 false Automatic Light Control Sensor 4.646,3.969 6.01,4.125 1.365,0.156 10 false G44 4.646,4.125 6.833,4.552 2.188,0.427 10 false Main Body ECU (Multiplex Network Body ECU) 1.021,4.479 3.24,4.677 2.219,0.198 10 false : CAN Communication Line 4.594,1.646 5.052,1.823 0.458,0.177 10 false 23 4.885,1.646 5.344,1.823 0.458,0.177 10 false CLTB 4.594,2.427 5.052,2.604 0.458,0.177 10 false 24 4.906,2.427 5.365,2.604 0.458,0.177 10 false CLTS 4.615,3.094 5.073,3.271 0.458,0.177 10 false 25 4.906,3.083 5.365,3.26 0.458,0.177 10 false CLTE 3.104,1.646 3.563,1.823 0.458,0.177 10 false CLTB 3.625,1.656 4.083,1.833 0.458,0.177 10 false 1 3.125,2.438 3.583,2.615 0.458,0.177 10 false CLTS 3.615,2.427 4.073,2.604 0.458,0.177 10 false 4 3.615,3.104 4.073,3.281 0.458,0.177 10 false 2 3.125,3.115 3.583,3.292 0.458,0.177 10 false CLTE

CAUTION / NOTICE / HINT

NOTICE:
·

If DTC B1244 is output, troubleshoot for DTC B1244 first.

Click hereVehicle Exterior>LIGHTING (EXT)>LIGHTING SYSTEM>B1244

·

Before replacing the main body ECU (multiplex network body ECU), refer to Service Bulletin.



PROCEDURE

1.CHECK MALFUNCTION STATUS
Result:
Result Proceed to
While cooling A
While heater B



A

2.CHECK REFRIGERANT SHORTAGE

B

6.BLEED AIR FROM COOLANT
2.CHECK REFRIGERANT SHORTAGE
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 121 3186

e.

Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.

Measurement Condition:
Item Condition
Vehicle Condition Power switch on (READY)
A/C Switch On
Ambient Temperature*1 0 to 49°C (32 to 120°F)
Air Conditioning Air Inlet Temperature*2 25 to 35°C (77 to 95°F)
Set Temperature MAX COLD
Recirculation/fresh Control Switch Recirculation
Air Vent Damper Position FACE
Blower Speed HI

HINT:
·

Refer to the GTS operator's manual for further details.

·

A message indicating a refrigerant shortage is displayed on the GTS and the air conditioning system turns off if the amount of refrigerant in the system is insufficient.

·

DTCs are not stored when performing the refrigerant shortage check using the GTS.

·

*1: This inspection can be judged correctly only if the ambient temperature is within a range of 0 to 49°C (32 to 120°F). Therefore, postpone the test if the temperature is low.

·

*2: This inspection can be judged correctly only if the air inlet temperature is within a range of 25 to 35°C (77 to 95°F). Therefore, postpone the test if the temperature is out of range.



Result:
Result Amount of Refrigerant
Refrigerant shortage Insufficient or leakage
Refrigerant correct Correct


OK:

"Refrigerant correct" is displayed on GTS.



Result:
Proceed to
OK
NG



OK

3.PERFORM ACTIVE TEST USING GTS (SERVO PULSE)

NG

3.PERFORM ACTIVE TEST USING GTS (SERVO PULSE)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Check the operation by referring to the table below.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 165 to 257 pulses


for RHD:

Operates between 255 to 347 pulses


Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) pulse Min.: 128
Max.: 383
for LHD:

Operates between 255 to 347 pulses


for RHD:

Operates between 165 to 257 pulses


Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(P)
50004 121 25
OK:

Damper servo motor is operated.



Result:
Proceed to
OK
NG



OK

4.CHECK HARNESS AND CONNECTOR (AUTOMATIC LIGHT CONTROL SENSOR - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))

NG

4.CHECK HARNESS AND CONNECTOR (AUTOMATIC LIGHT CONTROL SENSOR - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))
a.

Disconnect the H1 automatic light control sensor connector.


b.

Disconnect the G44 main body ECU (multiplex network body ECU) connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
H1-1 (CLTB) - G44-23 (CLTB) Always Below 1 Ω
H1-2 (CLTE) - G44-25 (CLTE) Always Below 1 Ω
H1-4 (CLTS) - G44-24 (CLTS) Always Below 1 Ω
H1-1 (CLTB) or G44-23 (CLTB) - Other terminals and body ground Always 10 kΩ or higher
H1-2 (CLTE) or G44-25 (CLTE) - Other terminals and body ground Always 10 kΩ or higher
H1-4 (CLTS) or G44-24 (CLTS) - Other terminals and body ground Always 10 kΩ or higher



Result:
Proceed to
OK
NG



OK

5.INSPECT AUTOMATIC LIGHT CONTROL SENSOR

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

5.INSPECT AUTOMATIC LIGHT CONTROL SENSOR
a.

Remove the automatic light control sensor.

Click hereVehicle Exterior>LIGHTING (EXT)>AUTOMATIC LIGHT CONTROL SENSOR>REMOVAL


b.

Inspect the automatic light control sensor.

Click hereVehicle Exterior>LIGHTING (EXT)>AUTOMATIC LIGHT CONTROL SENSOR>ON-VEHICLE INSPECTION


Result:
Proceed to
OK
NG



OK

NG

REPLACE AUTOMATIC LIGHT CONTROL SENSOR

6.BLEED AIR FROM COOLANT

NEXT

7.CHECK OPERATION (AIR CONDITIONING SYSTEM)
7.CHECK OPERATION (AIR CONDITIONING SYSTEM)
a.

Check that there is not a difference in temperature between the left and right air outlets.

OK:

There is not a difference in temperature between the left and right air outlets.



Result:
Proceed to
OK
NG



OK

END (FAILURE DUE TO AIR ENTERING COOLANT)

NG

8.PERFORM ACTIVE TEST USING GTS (SERVO PULSE)
8.PERFORM ACTIVE TEST USING GTS (SERVO PULSE)
a.

Connect the GTS to the DLC3.


b.

Turn the power switch on (IG).


c.

Turn the GTS on.


d.

Enter the following menus: Body Electrical / Air Conditioner / Active Test.


e.

Check the operation by referring to the table below.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Mix Servo Targ Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly (driver side air mix) operation Min.: 128
Max.: 383
for LHD:

Operates between 165 to 257 pulses


for RHD:

Operates between 255 to 347 pulses


Air Mix Servo Targ Pulse(P) No. 1 air conditioning radiator damper servo sub-assembly (front passenger side air mix) operation Min.: 128
Max.: 383
for LHD:

Operates between 255 to 347 pulses


for RHD:

Operates between 165 to 257 pulses


Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(D)
50004 121 24
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Mix Servo Targ Pulse(P)
50004 121 25
OK:

Damper servo motor is operated.



Result:
Proceed to
OK
NG



OK

NG

GO TO DIAGNOSTIC TROUBLE CODE CHART (FOR SERVO MOTOR OF APPLICABLE ABNORMAL OPERATION)