Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › INVERTER WITH CONVERTER (for 2WD) › from 2019.02
RM3620E _51 Engine / Hybrid System _076333 HYBRID / BATTERY CONTROL _0371632 INVERTER WITH CONVERTER(for 2WD) A

HYBRID / BATTERY CONTROL  INVERTER WITH CONVERTER(for 2WD)  INSTALLATION  


PROCEDURE

Hide 1.INSTALL WIRE HARNESS CLAMP BRACKET

a.

Install the wire harness clamp bracket to the inverter with converter assembly with the bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


b.

Install the wire harness clamp bracket to the inverter with converter assembly with the bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


c.

Install the 2 wire harness clamp brackets to the inverter with converter assembly with the 2 bolts.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


Hide G9215 2.INSTALL NO. 2 INVERTER BRACKET

NOTICE:
A406195C03
0.875,1.094 1.75,1.958 1.75,1.958 2.396,1.135 true 0.135,0.125 0.448,0.281 0.313,0.156 10 false *a 1.698,1.99 2.01,2.146 0.313,0.156 10 false *b
*a Bottom of Inverter with Converter Assembly
*b Support


Make sure to support the inverter with converter assembly at the positions shown in the illustration, otherwise it may be damaged.


a.
A431496C02
2.188,1.833 2.813,1.927 2.813,1.927 2.615,1.635 true 2.865,1.875 3.177,2.031 0.313,0.156 10 false *a 0.656,1 0.813,1.198 0.156,0.198 10 false 1 1.406,1.448 1.563,1.646 0.156,0.198 10 true 2
*a Wooden Block


Set the inverter with converter assembly on wooden blocks.


b.

Temporarily install the No. 2 inverter bracket to the inverter with converter assembly with the 2 bolts.


c.

Fully tighten the 2 bolts in the order shown in the illustration.

Torque:
15 N*m (153 kgf*cm, 11 ft.*lbf)


Hide G9214 3.INSTALL NO. 1 INVERTER BRACKET

a.
A431495C02
2.125,1.813 2.688,1.969 2.688,1.969 2.563,1.667 true 2.74,1.927 3.052,2.083 0.313,0.156 10 false *a 0.625,1.021 0.781,1.219 0.156,0.198 10 false 1 1.479,1.49 1.635,1.688 0.156,0.198 10 true 2
*a Wooden Block


Temporarily install the No. 1 inverter bracket to the inverter with converter assembly with the 2 bolts.


b.

Fully tighten the 2 bolts in the order shown in the illustration.

Torque:
15 N*m (153 kgf*cm, 11 ft.*lbf)


Hide G9200 4.INSTALL INVERTER WITH CONVERTER ASSEMBLY

CAUTION:

Be sure to wear insulated gloves.


a.

Temporarily install the inverter with converter assembly with the 5 bolts and 2 nuts.

NOTICE:
·

When installing the inverter with converter assembly, be careful not to damage the parts around it.

·

To prevent damage, do not hold the inverter with converter assembly by the connectors, brackets or cooling pipes.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.

·
A431502C01
0.667,2.51 0.875,2.698 0.208,0.188 10 true *a 0.656,3.583 0.875,3.76 0.219,0.177 10 true *b
*a Correct
*b Incorrect


Make sure that the inverter with converter assembly is positioned so that the stud bolts are in contact with the base of the U-shaped portions of the No. 1 inverter bracket.



HINT:

If the bolts and nuts are not tightened appropriately, the inverter with converter assembly may make an abnormal noise.



b.

Fully tighten the bolt (A).

Torque:
55 N*m (561 kgf*cm, 41 ft.*lbf)

A431494N01
0.896,1.917 1.083,2.125 0.188,0.208 10 true A 1.792,1.938 1.958,2.115 0.167,0.177 10 true B 2.271,1.979 2.438,2.156 0.167,0.177 10 true B 2.708,1.927 2.875,2.104 0.167,0.177 10 true B 6.198,2.542 6.354,2.74 0.156,0.198 10 true C 5.698,2.573 5.854,2.771 0.156,0.198 10 true D 4.833,2.51 4.99,2.708 0.156,0.198 10 true D


c.

Fully tighten the 3 bolts (B).

Torque:
55 N*m (561 kgf*cm, 41 ft.*lbf)


d.

Fully tighten the bolt (C).

Torque:
55 N*m (561 kgf*cm, 41 ft.*lbf)


e.

Fully tighten the 2 nuts (D).

Torque:
55 N*m (561 kgf*cm, 41 ft.*lbf)


Hide G1148 5.CONNECT MOTOR CABLE

CAUTION:

Be sure to wear insulated gloves.


NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Adhere to the following installation procedure. Otherwise, the connector and the inverter with converter assembly may be damaged.



a.

Temporarily connect the motor cable to the inverter with converter assembly with the 4 bolts.

NOTICE:
·

Do not touch the waterproof seal or terminals of the motor cable.

·

Do not damage the terminals, connector housing or inverter with converter assembly during connection.




b.
A431492C02
0.99,0.25 1.323,0.25 1.323,0.25 1.573,0.469 true 0.813,0.177 1.125,0.333 0.313,0.156 10 false *a 3.135,1.458 3.292,1.656 0.156,0.198 10 true A 0.396,2.896 0.552,3.094 0.156,0.198 10 true 1 0.323,1.615 0.448,1.792 0.125,0.177 10 true 2 3.073,2.521 3.208,2.688 0.135,0.167 10 true 3
*a Waterproof Seal


Fully tighten the bolt (A).

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


c.

Fully tighten the 3 bolts in the order shown in the illustration to connect the motor cable to the inverter with converter assembly.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


d.
A431491

Temporarily install the 6 bolts.

NOTICE:
·

To prevent the threads from being damaged, temporarily tighten the 6 bolts by hand.

·

Do not touch the waterproof seal or terminals of the motor cable.

·

Do not damage the terminals, connector housing or inverter with converter assembly during connection.




e.

Using an insulated tool, fully tighten the 6 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:
·

Do not touch the waterproof seal or terminals of the motor cable.

·

Do not damage the terminals, connector housing or inverter with converter assembly during connection.

·

Be sure to use a torque wrench to tighten the bolts.




Hide G9221 6.INSTALL INVERTER COVER

CAUTION:

Be sure to wear insulated gloves.


a.

Install the inverter cover to the inverter with converter assembly with the 2 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:
·

Visually confirm that the inverter cover waterproof seal is securely installed before installing the inverter cover.

·

Do not touch the waterproof seal of the inverter cover.

·

Make sure that the interlock is fully engaged.

·

Do not damage the terminals, interlock connector or inverter with converter assembly during installation.

·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·
A376320C03
2.167,2.115 2.656,1.635 2.656,1.635 2.031,1.24 false 1.031,0.313 1.302,0.313 1.302,0.313 1.823,0.781 true 0.865,0.188 1.177,0.385 0.313,0.198 10 false *a 2.698,1.521 3.01,1.719 0.313,0.198 10 false *1
*1 Inverter Cover
*a Do not remove or excessively tighten the screw


Do not remove or excessively tighten the screw of the inverter cover.

·

Although the inverter cover may feel loose, this is not due to a malfunction.

·
A406203C02
1.667,1.885 1.875,2.063 0.208,0.177 10 true *a
*a No Gap


Push in the inverter cover until it contacts the inverter with converter assembly.




Hide G9228A 7.CONNECT NO. 4 INVERTER COOLING HOSE

a.
A431504C01
0.76,0.958 0.667,0.594 0.667,0.594 0.469,0.594 true 1.292,0.979 1.156,0.458 1.156,0.458 0.958,0.458 true 0.302,0.5 0.615,0.656 0.313,0.156 10 false *a 0.802,0.375 1.115,0.531 0.313,0.156 10 false *b 1.083,1.552 1.396,1.708 0.313,0.156 10 false *c 2.323,0.135 2.635,0.292 0.313,0.156 10 false *d 3.01,0.917 3.323,1.073 0.313,0.156 10 false *e 2.635,0.375 3.01,0.563 0.375,0.188 10 false 120°
*a Alignment Mark (Yellow)
*b Rib
*c 2 to 7 mm (0.0787 to 0.276 in.)
*d Up
*e LH Side


Connect the No. 4 inverter cooling hose to the inverter with converter assembly and slide the clip to secure it.

NOTICE:
·

To prevent foreign matter from entering the inverter with converter assembly and inverter cooling system, do not remove the pieces of cloth from the pipe and disconnected hose until installation.

·

Make sure to align the alignment mark of the hose with the rib of the inverter with converter assembly.



HINT:

Make sure that the clip is positioned as shown in the illustration.



Hide G9225K 8.CONNECT NO. 1 INVERTER COOLING HOSE

a.
A431505C01
0.49,0.521 0.667,0.521 0.667,0.521 0.76,0.958 true 1,0.375 1.177,0.375 1.177,0.375 1.292,0.958 true 0.323,0.427 0.635,0.583 0.313,0.156 10 false *a 0.833,0.292 1.146,0.448 0.313,0.156 10 false *b 1.073,1.552 1.385,1.708 0.313,0.156 10 false *c 2.323,0.135 2.635,0.292 0.313,0.156 10 false *d 3.01,0.927 3.323,1.083 0.313,0.156 10 false *e 2.635,0.354 3.073,0.563 0.438,0.208 10 false 120°
*a Alignment Mark (White)
*b Rib
*c 2 to 7 mm (0.0787 to 0.276 in.)
*d Up
*e LH Side


Connect the No. 1 inverter cooling hose to the inverter with converter assembly and slide the clip to secure it.

NOTICE:
·

To prevent foreign matter from entering the inverter with converter assembly and inverter cooling system, do not remove the pieces of cloth from the pipe and disconnected hose until installation.

·

Make sure to align the alignment mark of the hose with the rib of the inverter with converter assembly.



HINT:

Make sure that the clip is positioned as shown in the illustration.



Hide 33820B 9.CONNECT TRANSMISSION CONTROL CABLE ASSEMBLY

a.

Connect the transmission control cable assembly to the inverter with converter assembly with the 3 bolts.

Torque:
12 N*m (122 kgf*cm, 9 ft.*lbf)


b.
C377951N01
2.833,1.385 2.99,1.583 0.156,0.198 10 false N 2.583,2 2.75,2.177 0.167,0.177 10 false P

Turn the control shaft lever clockwise until it stops, then turn it counterclockwise 2 notches.


c.

Engage the 2 claws to install a new clip to the transmission control cable assembly.


d.
C377953C01
1.25,1.385 0.969,0.573 0.969,0.573 2.167,1.365 true 1.146,1.635 2.948,2.521 2.948,2.521 2.313,1.646 true 2.646,1.063 2.75,0.698 2.75,0.698 2.896,0.698 false 1.26,2.979 1.406,2.979 1.406,2.979 1.583,2.417 true 1.094,2.917 1.385,3.156 0.292,0.24 10 false *1 2.958,0.625 3.26,0.802 0.302,0.177 10 false *2 0.792,0.479 1.104,0.667 0.313,0.188 10 false *a 3,2.469 3.313,2.625 0.313,0.156 10 false *b
*1 Transmission Control Cable Assembly
*2 No. 1 Transmission Control Cable Bracket
*a Claw (A)
*b Claw (B)


Using a screwdriver, engage the 4 claws and install the transmission control cable assembly to the No. 1 transmission control cable bracket.

NOTICE:
·

Make sure that the claws (A) of the clip are securely engaged in the grooves of the bracket.

·

Make sure that the transmission control cable assembly is securely installed inside of the claws (B) of the clip.




e.

Connect the transmission control cable assembly to the control shaft lever with the nut.

Torque:
12 N*m (122 kgf*cm, 9 ft.*lbf)


Hide 82121 10.CONNECT ENGINE WIRE

CAUTION:

Be sure to wear insulated gloves.


NOTICE:

Do not allow any foreign matter or water to enter the inverter with converter assembly.


a.
A431483

Engage the 2 clamps and connect the engine wire to the inverter with converter assembly.


b.

Temporarily install the nut.

NOTICE:

To prevent the threads from being damaged, temporarily tighten the nut by hand.



c.

Fully tighten the nut.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


d.

Engage the 2 claws to close the engine wire terminal cover.


e.
A431481

Connect the engine wire to the inverter with converter assembly with the bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


f.
A431480

Connect the engine wire to the inverter with converter assembly with the bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


g.

Engage the 2 clamps.


h.

Engage the clamp.


i.

Confirm that no foreign matter or water has entered the connector of the generator temperature sensor, resolver (transmission fluid temperature sensor) and shift lever position sensor and connect the 3 connectors.


j.
A431477N01
2.375,0.385 2.5,0.542 0.125,0.156 10 true B 2.177,2.417 2.302,2.573 0.125,0.156 10 true A 0.74,2.51 0.865,2.667 0.125,0.156 10 true A

Engage the clamp (B).


k.

Connect the engine wire to the intake manifold with the bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


l.

Engage the 2 clamps (A) and connect the No. 1 fuel vapor feed hose and No. 2 fuel vapor feed hose.


m.

Connect the EGR valve connector.


n.
A433718N01
1.729,0.281 1.875,0.438 0.146,0.156 10 true A 1.219,1.646 1.365,1.802 0.146,0.156 10 true A 1.083,0.354 1.229,0.51 0.146,0.156 10 true B 0.781,2.708 0.927,2.865 0.146,0.156 10 true B

Engage the 2 clamps (B).


o.

Connect the engine wire to the inverter with converter assembly with the bolt.

Torque:
10 N*m (102 kgf*cm, 7 ft.*lbf)


p.

Engage the 2 clamps (A) and connect the No. 1 fuel vapor feed hose.


q.
A433721

Connect the inverter with converter assembly connector and move the lock lever to lock them.

NOTICE:
·

Do not touch the waterproof seal or terminals of the connectors.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.

·

Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connectors.




Hide 11.INSTALL WIRE HARNESS CLAMP BRACKET

a.

Install the wire harness clamp bracket to the inverter with converter assembly with the nut.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


Hide 821H2 12.CONNECT HV AIR CONDITIONING WIRE

CAUTION:

Be sure to wear insulated gloves.


a.
A431473C01
0.688,0.635 1.125,0.427 1.125,0.427 1.542,0.427 true 1.604,0.344 1.917,0.5 0.313,0.156 10 false *a
*a Waterproof Seal


Engage the clamp and connect the HV air conditioning wire to the inverter with converter assembly.

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connector.




b.

Install the 2 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


Hide 821H1 13.CONNECT HV FLOOR UNDER WIRE

CAUTION:

Be sure to wear insulated gloves.


a.
A431506C01
0.74,0.646 1.01,0.188 1.01,0.188 1.417,0.188 true 1.458,0.125 1.771,0.281 0.313,0.156 10 false *a
*a Waterproof Seal


Engage the 2 clamps and connect the HV floor under wire to the inverter with converter assembly.

NOTICE:
·

Do not allow any foreign matter or water to enter the inverter with converter assembly.

·

Do not touch the waterproof seal or terminals of the connector.

·

Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connector.




b.

Install the 2 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


Hide 82111 14.CONNECT ENGINE ROOM MAIN WIRE

CAUTION:

Be sure to wear insulated gloves.


a.

Engage the clamp to connect the engine room main wire to the inverter with converter assembly.


b.

Install the bolt.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


c.
A431507

Connect the inverter with converter assembly connector and move the lock lever to lock them.

NOTICE:
·

Do not touch the waterproof seal or terminals of the connectors.

·

To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.

·

Do not damage the terminals, connector housing or inverter with converter assembly when connecting the connectors.




Hide 16.INSTALL AIR CLEANER ASSEMBLY WITH AIR CLEANER HOSE

Hide 17750A 17.INSTALL INLET AIR CLEANER ASSEMBLY

Hide 12601B 18.INSTALL NO. 1 ENGINE COVER SUB-ASSEMBLY

Hide 20.ADD COOLANT (for Inverter)

Hide 24.PERFORM INITIALIZATION