The necessary procedures (adjustment, calibration, initialization, or registration) that must be performed after parts are removed and installed, or replaced during inverter with converter assembly removal/installation are shown below.
Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.
for NICKEL METAL HYDRIDE BATTERY:
for LITHIUM-ION BATTERY:
To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.
After the power switch is turned off, the navigation system requires approximately a minute to record various types of memory and settings. As a result, after turning the power switch off, wait a minute or more before disconnecting the cable from the negative (-) auxiliary battery terminal.
1. PRECAUTION
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
G3834
2.REMOVE SERVICE PLUG GRIP
3.DRAIN COOLANT (for Inverter)
12601B
4.REMOVE NO. 1 ENGINE COVER SUB-ASSEMBLY
for A25A-FXS:
Click hereEngine / Hybrid System>A25A-FXS (ENGINE MECHANICAL)>ENGINE ASSEMBLY>REMOVAL
for A25B-FXS:
Click hereEngine / Hybrid System>A25B-FXS (ENGINE MECHANICAL)>ENGINE ASSEMBLY>REMOVAL
17750A
5.REMOVE INLET AIR CLEANER ASSEMBLY
for A25A-FXS:
Click hereEngine / Hybrid System>A25A-FXS (ENGINE CONTROL)>THROTTLE BODY>REMOVAL
for A25B-FXS:
Click hereEngine / Hybrid System>A25B-FXS (ENGINE CONTROL)>THROTTLE BODY>REMOVAL
6.REMOVE AIR CLEANER ASSEMBLY WITH AIR CLEANER HOSE
for A25A-FXS:
Click hereEngine / Hybrid System>A25A-FXS (ENGINE CONTROL)>THROTTLE BODY>REMOVAL
for A25B-FXS:
Click hereEngine / Hybrid System>A25B-FXS (ENGINE CONTROL)>THROTTLE BODY>REMOVAL
89661
7.REMOVE ECM
for A25A-FXS:
Click hereEngine / Hybrid System>A25A-FXS (ENGINE CONTROL)>ECM>REMOVAL
for A25B-FXS:
Click hereEngine / Hybrid System>A25B-FXS (ENGINE CONTROL)>ECM>REMOVAL
82111
8.DISCONNECT ENGINE ROOM MAIN WIRE
Be sure to wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Move the lock lever while pushing the lock on the connector, and disconnect the inverter with converter assembly connector.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
Insulate the disconnected terminals with insulating tape.
Do not touch the waterproof seal or terminals of the connector.
Remove the bolt.
Disengage the clamp and disconnect the engine room main wire.
9.REMOVE CONNECTOR COVER ASSEMBLY
Be sure to wear insulated gloves.
| *a | Bolt (A) |
| *b | Bolt (B) |
Remove the bolt (B).
Using a T25 "TORX" socket wrench, remove the bolt (A) and connector cover assembly from the inverter with converter assembly.
Do not touch the connector cover assembly waterproof seal.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
10.CHECK TERMINAL VOLTAGE
Be sure to wear insulated gloves.
Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.
0 V
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Use a measuring range of DC 750 V or more on the voltmeter.
11.TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY
Be sure to wear insulated gloves.
Temporarily install the connector cover assembly to the inverter with converter assembly.
Using a T25 "TORX" socket wrench, install the bolt.
Do not touch the connector cover assembly waterproof seal.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
821H1
12.DISCONNECT FLOOR UNDER WIRE
Be sure to wear insulated gloves.
| *a | Waterproof Seal |
Remove the 2 bolts and disconnect the HV floor under wire from the inverter with converter assembly.
Do not damage the terminals, interlock connector or inverter with converter assembly during disconnection.
Do not touch the waterproof seal or terminals of the connector.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Although the connector may feel loose, this is not due to a malfunction.
Remove the 2 nuts and disconnect the HV floor under wire from the inverter with converter assembly.
| *a | Waterproof Seal |
Remove the bolt and disconnect the HV floor under wire from the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the connector.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Insulate the disconnected terminals with insulating tape.
821H2
13.DISCONNECT HV AIR CONDITIONING WIRE
Be sure to wear insulated gloves.
| *a | Waterproof Seal |
Remove the 2 bolts.
Disengage the clamp and disconnect the HV air conditioning wire from the inverter with converter assembly.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the connector.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Insulate the disconnected terminals with insulating tape.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
14.REMOVE WIRE HARNESS CLAMP BRACKET
Remove the nut and wire harness clamp bracket.
82121
15.DISCONNECT ENGINE WIRE
Be sure to wear insulated gloves.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Move the lock lever while pushing the lock on the connector, and disconnect the inverter with converter assembly connector.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
Insulate the disconnected terminals with insulating tape.
Do not touch the waterproof seal or terminals of the connector.
Disengage the clamp (A) and disconnect the No. 1 fuel vapor feed hose.
Remove the bolt.
Disengage the 3 clamps (B).
Disengage the 2 clamps (A) and disconnect the No. 1 fuel vapor feed hose and No. 2 fuel vapor feed hose.
Remove the bolt.
Disengage the clamp (B).
Disconnect the EGR valve connector.
| *a | Generator Temperature Sensor Connector |
| *b | Resolver (Transmission Fluid Temperature Sensor) Connector |
| *c | Shift Lever Position Sensor Connector |
Disconnect the generator temperature sensor connector, resolver (transmission fluid temperature sensor) connector and shift lever position sensor connector and disengage the clamp.
After disconnecting the engine wire, cover the connector of the generator temperature sensor, resolver (transmission fluid temperature sensor) and shift lever position sensor with tape (non-residue type) or equivalent to prevent the entry of foreign matter or water.
Disengage the 2 clamps.
Remove the bolt.
Remove the bolt.
Disengage the 2 claws and open the engine wire terminal cover.
Remove the nut.
Disengage the 2 clamps and disconnect the engine wire from the inverter with converter assembly.
33820B
16.DISCONNECT TRANSMISSION CONTROL CABLE ASSEMBLY
Remove the nut and disconnect the transmission control cable assembly from the control shaft lever.
Using a screwdriver, disengage the 4 claws and disconnect the transmission control cable assembly with the clip from the No. 1 transmission control cable bracket.
Using a screwdriver, disengage the 2 claws and remove the clip from the transmission control cable assembly.
Remove the 2 bolts and disconnect the transmission control cable assembly from the inverter with converter assembly.
G9225K
17.DISCONNECT NO. 1 INVERTER COOLING HOSE
Slide the clip and disconnect the No. 1 inverter cooling hose from the inverter with converter assembly.
Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.
G9228A
18.DISCONNECT NO. 4 INVERTER COOLING HOSE
Slide the clip and disconnect the No. 4 inverter cooling hose from the inverter with converter assembly.
Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.
G9221
19.REMOVE INVERTER COVER
Be sure to wear insulated gloves.
| *a | Interlock |
| *b | Waterproof Seal |
Remove the 2 bolts and inverter cover from the inverter with converter assembly.
Make sure to pull the inverter cover straight out, as a connector is connected to the inside of the inverter cover.
Do not touch the waterproof seal of the inverter cover.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
When removing the inverter cover, do not pull the areas (A) as they may deform.
Make sure that the interlock is installed to the inverter cover.
| *1 | Inverter Cover |
| *a | Do not remove or excessively tighten the screw |
Do not remove or excessively tighten the screw of the inverter cover.
Although the inverter cover may feel loose, this is not due to a malfunction.
If necessary, use a screwdriver with its tip wrapped with protective tape as shown in the illustration to remove the inverter cover.
G1148
20.DISCONNECT MOTOR CABLE
Be sure to wear insulated gloves.
Adhere to the following removal procedure. Otherwise, the connector and the inverter with converter assembly may be damaged.
Using an insulated tool, remove the 6 bolts.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the motor cable.
| *a | Waterproof Seal |
Remove the 4 bolts and disconnect the motor cable from the inverter with converter assembly.
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Do not touch the waterproof seal or terminals of the motor cable.
Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
Insulate the disconnected terminals with insulating tape.
After disconnecting the motor cable, wrap it with a plastic bag or equivalent to protect it.
Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
To prevent the wire harness from being caught, make sure to bundle the wire harness using insulating tape or equivalent.
G9200
21.REMOVE INVERTER WITH CONVERTER ASSEMBLY
Be sure to wear insulated gloves.
Remove the 5 bolts, 2 nuts and inverter with converter assembly.
When removing the inverter with converter assembly, be careful not to damage the parts around it.
To prevent damage, do not hold the inverter with converter assembly by the connectors, brackets or cooling pipes.
To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
Even after the coolant is drained, coolant remains in the inverter due to its internal structure. Therefore, seal or cover the pipes when removing the inverter with converter assembly so that coolant does not spill out.
G9214
22.REMOVE NO. 1 INVERTER BRACKET
| *a | Bottom of Inverter with Converter Assembly |
| *b | Support |
Make sure to support the inverter with converter assembly at the positions shown in the illustration, otherwise it may be damaged.
| *a | Wooden Block |
Set the inverter with converter assembly on wooden blocks.
Remove the 2 bolts and No. 1 inverter bracket from the inverter with converter assembly.
G9215
23.REMOVE NO. 2 INVERTER BRACKET
| *a | Wooden Block |
Remove the 2 bolts and No. 2 inverter bracket from the inverter with converter assembly.
24.REMOVE WIRE HARNESS CLAMP BRACKET
Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.
Remove the bolt and wire harness clamp bracket from the inverter with converter assembly.
Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.
Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.
Remove the 2 bolts and wire harness clamp bracket from the inverter with converter assembly.